Table 8 Fabric OS 6.2.1 closed defects (continued)
Closed defect summary
In an FCR environment (with a router or switch configured for FCR), a switch
runs out of memory when it is connected with the Mi10k. The Mi10k sends
continuous RRQ frames because the Fabric OS-based switch did not handle
RRQ frames with either accept or reject.
Several problems occurred that were related to the configdownload
commands. Some of these problems caused a core dump.
A switch panic/hafailover occurs due to a weblinker.cfg panic seen
during overnight slot command script test when modify/distribute ACL
database, and during RNID response processing.
A blade fault occurred in HP StorageWorks 4/256 SAN director on an
8-Gb 48-port blade in either slot 1 or slot 10 when the director was fully
loaded with 8-Gb 48-port blades.
Starting with Fabric OS 6.1.2, supportsave was updated to collect more
data. A Parity error may be logged as data is read from disabled ports on
switches that were updated from a lower code level but never cold booted.
Frame Redirect zones cannot be created when defzone is set to
allaccess.
Memory leak during security script testing.
In 8-Gb routed fabric, PLOGI in acceleration path did not program cam
entry properly, leading to backbone hosts not being able to see edge fabric
target.
FCIP tunnels on the HP StorageWorks 400 MP Router or the MP Router
blade do not come up due to a timing issue caused when using
optical-to-copper converters in the path.
In a cascaded Access Gateway configuration of three switches with both
AGs in port group mode, when the QoS license is removed from the fabric
switch and switchdisable/enable is performed, traffic continues for
medium priority flows, but stops flowing for high and low priorities until the
QoS license is reinstalled.
When a trunk master port is disabled, Fabric Watch incorrectly sets the
new trunk master's health to offline and the remote side to faulty, even
though the port is online. This is a Web Tools display problem with no
functionality impact.
Unable to get F_Ports (trunk ports) data from Web Tools, but CLI works.
Fabric becomes unstable after changing EX_Port trunk to E_Port trunk.
Switches bounce between reachable and unreachable in edge fabric.
Fabric OS 6.2 RADIUS Calling-station-ID (31) implementation is used for
both device called by and workstation called from host
name/IP address. As a result, RADIUS will not work properly and restriction
of host access is not possible.
When the host transmits PLOGI to the name server in Access Gateway
mode, the name server responds with ACK then ACC. The AG forwards
the ACC to the host, which responds with ACK, but it never gets forwarded
back to the name server, causing the exchange to abort.
OpenVMS init command does not complete, which prevents OpenVMS
from mounting the file system with either the HP StorageWorks Encryption
SAN Switch, or the encryption blade.
During blade insertion or switch power up, the port fence disabled ports
that are running diagtest trigger blade fault during blade POST.
36
Solution
Fixed in Fabric OS 6.2.1
Fixed in Fabric OS 6.2.1
Fixed in Fabric OS 6.2.1
Fixed in Fabric OS 6.2.1
Fixed in Fabric OS 6.2.1
Fixed in Fabric OS 6.2.1
Workaround prior to update: Set
defzone to noaccess.
Fixed in Fabric OS 6.2.1
Fixed in Fabric OS 6.2.1
Fixed in Fabric OS 6.2.1
Fixed in Fabric OS 6.2.1
Fixed in Fabric OS 6.2.1
Fixed in Fabric OS 6.2.1
Fixed in Fabric OS 6.2.1
Fixed in Fabric OS 6.2.1
Fixed in Fabric OS 6.2.1
Fixed in Fabric OS 6.2.1
Fixed in Fabric OS 6.2.1