Are both drive module LEDs off (Online/Activity and Fault/UID)?

Answer
Yes

Is the drive module Fault/UID LED blinking amber?

Answer
No, but the
Online/Activity
LED is blinking.
Yes, and the
Online/Activity
LED is off.
Yes, and the
Online/Activity
LED is blinking.

Is a connected host port's Host Link Status LED off?

Answer
Possible Reasons
No
System functioning properly.
Yes
The link is down.
Possible Reasons
There is no power.
The drive is offline.
The drive is not
configured.
Possible Reasons
The drive is rebuilding.
The drive is offline. A predictive failure
alert may have been received for this
device.
The drive is active, but a predictive
failure alert may have been received
for this device.
Actions
Check that the drive is fully inserted and latched in place,
and that the enclosure is powered on.
Actions
No action required.
CAUTION:
is rebuilding. Removing a drive might
terminate the current operation and
cause data loss.
Check the event log for specific information
regarding the fault.
Isolate the fault.
Contact an authorized service provider for
assistance.
Check the event log for specific information
regarding the fault.
Isolate the fault.
Contact an authorized service provider for
assistance.
Actions
No action required.
(see
Link LED
note: page 38)
Check cable connections and reseat if necessary.
Inspect cables for damage.
Swap cables to determine if fault is caused by a
defective cable. Replace cable if necessary.
Verify that the switch, if any, is operating properly. If
possible, test with another port.
Verify that the HBA is fully seated, and that the PCI slot is
powered on and operational.
In SMU, review event logs for indicators of a specific
fault in a host data path component.
Contact an authorized service provider for assistance.
See
Isolating a host-side connection fault
HP StorageWorks 2000i G2 Modular Smart Array User Guide