Diagnosing Array Problems; Controller Board Runtime Leds - HP 273914-B21 - Smart Array 6404/256 RAID Controller User Manual

Smart array 6400 series controllers user guide
Hide thumbs Also See for 273914-B21 - Smart Array 6404/256 RAID Controller:
Table of Contents

Advertisement

Diagnosing array problems

In this section

Controller board runtime LEDs

Cache module
LEDs.....................................................................................................................53
Diagnostic tools
............................................................................................................................54
Controller board runtime LEDs
LED ID
Color
0
Amber
1
Amber
2
Blue
3
Green
....................................................................................................51
NOTE: During server power-up, each runtime LED illuminates
randomly until POST has finished.
LED name and interpretation
CR100: Diagnostics Error LED.
CR101: Drive Failure LED. A physical drive connected to the controller
has failed.
CR102: SCSI Bus Active LED. At least one of the SCSI buses on the
controller is active.
CR103: XOR Active LED. The controller is calculating parity data.
51

Advertisement

Table of Contents
loading

Table of Contents