HP 3100ES - Smart Array RAID Controller Manual page 8

Raid 1(+0): breaking mirrors and rebuilding drives

Advertisement

Figure 2. Boot-up message indicating no logical drives were found and that the backup drives are probably in
the wrong drive bays
During boot-up, the message will indicate that the drives are not responding (Figure 2). Press F2 to
3.
fail the missing drive and continue with one drive in recovery mode.
Insert the drive to be overwritten into the open drive bay, and the array rebuild should start
4.
automatically. If the rebuild does not start automatically, run the Array Configuration Utility to
initiate the rebuild.
CAUTION
It is critical that the drives to be overwritten are hot inserted;
they must not be installed while the server is powered off.
NOTE
The drive-online LED will blink during the rebuild process. When
it stops blinking and turns solid green, the rebuild is complete. A
300-GB SAS (3.5" 15K) drive can take up to 2 hours to rebuild
a mirrored (depending on the number of IOPS the server is
submitting to the controller).
It is recommended that once the rebuild is complete, proceed with the operating system re-boot to
5.
ensure fault-tolerance with the logical drive.