Summary of Contents for Honeywell Home ADEMCO VISTA-20PSIA
Page 1
ADEMCO VISTA SERIES VISTA-15P VISTA-15PSIA VISTA-20P VISTA-20PSIA User Guide K5309-1V7C 3/15 Rev C VISTA-15P/15PSIA & VISTA-20P/20PSIA...
Page 2
IMPORTANT! PROPER INTRUSION PROTECTION For proper intrusion coverage, sensors should be located at every possible point of entry to a home or commercial premises. This would include any skylights that may be present, and the upper windows in a multi-level building. In addition, we recommend that radio backup be used in a security system so that alarm signals can still be sent to the Central Monitoring Station in the event that the telephone lines are out of order (alarm signals are normally sent over the phone lines).
Table of Contents System Overview ........................1 Introduction ........................... 1 System Basics ........................1 Using the Voice Message Center (if Voice Keypad is installed) .......... 3 About the Keypads ........................4 General Information ......................4 FIXED-WORD DISPLAY KEYPAD..................6 Functions of the Keypads ......................7 Entry/Exit Delays ........................
Page 4
Table of Contents (Continued) Paging Feature ........................26 About Automatic Paging ..................... 26 About Manual Paging ......................27 Latch Key Paging ........................ 27 Security Codes & Authority Levels ..................28 About Security Codes ......................28 Authority Level Definitions ....................28 How to Assign Security Codes and User Attributes ............
System Overview Introduction Congratulations on your ownership of a Honeywell Home Security System. You've made a wise decision in choosing it, for it represents the latest in security protection technology today. This system provides: • Three forms of protection: burglary, fire* and emergency •...
Page 6
System Overview (Continued) Zones and Partitions • The system sensing devices have been assigned to various “zones,” which are specific areas of protection (e.g., front door, kitchen window, etc.). • Zone numbers are displayed at the keypad when an alarm or trouble condition occurs on a sensor. •...
System Overview (Continued) Function Keys • The “A,” “B,” “C,” and “D” keys can be programmed to perform various functions. • Functions include: activate a panic alarm, arm the system, provide step arming, switch lights on/off, send a message to a pager, display Time/Date, and start a programmed Macro sequence. Paging Feature •...
About the Keypads General Information Your keypads allow you to control all system functions and feature the following: • A telephone style (digital) keypad • Liquid Crystal Displays (LCD) that show the nature and location of all occurrences • Built-in sounder that sounds during alarms and troubles. The sounder also "beeps" during certain system functions and also when depressing any of the keys (to acknowledge the key press).
Page 9
About the Keypads (Continued) Standard Alpha Display Keypad Standard Fixed-Word Display Keypad Voice-Capable Alpha Display Keypad Wireless Key Fobs Your system may also include one or more wireless key fobs, which can perform various functions programmed by your installer. IMPORTANT SECURITY NOTICE Your key fob is similar to your keys or access card.
About the Keypads (Continued) FIXED-WORD DISPLAY KEYPAD AWAY: All burglary zones, interior and perimeter, are armed. STAY: Perimeter burglary zones, such as protected windows and doors, are armed. NIGHT-STAY: NIGHT and STAY indicators both FIXED-WORD DISPLAY light when perimeter burglary zones plus pre-selected interior zones (set by the installer) are armed.
Functions of the Keypads Voice-capable 2-line Alpha keypad (shown with flip-down front door removed) IMPORTANT! • Match the numerical callouts in the above graphic with the corresponding number on the following pages for a description of usage. • When entering codes and commands, sequential key depressions must be made within 4-5 seconds of one another.
Page 12
Functions of the Keypads (Continued) [PLAY] On Voice keypads, used in NOTE: The functions printed directly on the keys indicate their primary purpose; the functions conjunction with the FUNCTION and printed under some of the keys (shown in brackets VOICE keys to play the recorded under the respective key), indicate their alternate message.
Page 13
Functions of the Keypads (Continued) 15. MIC 11. # This key can be used for "Quick On voice keypads, microphone for Arming" of the system without use of a Message Center recordings. security code (if programmed). 16. MESSAGE LED INDICATOR: (RED) On [FUNCTION] On Voice keypads, enables Voice keypads, flashes red when the desired voice or volume function.
Entry/Exit Delays Entry Delay Entry Delays give you time to disarm the system when you re-enter through the designated entrance door. There are two entry delays (if programmed). The first is for your primary entrance and the second can be used for a secondary entrance, where a longer delay is required to walk to the keypad to disarm the system.
Entry/Exit Delays (Continued) Exit Alarms Exit Error Conditions Whenever you arm the system, the exit delay begins. If an entry/exit door or interior zone is faulted before exit delay expires and remains faulted (e.g., exit door left open), the system sounds an alarm and starts the entry delay timer.
Checking for Open Zones Using the [∗] Key to Display and Announce System Status efore arming your system, all protected doors, windows and other protection zones must be closed or bypassed; otherwise the keypad will display a "Not Ready" message. Use the READY key to display all faulted zones, making it easier for you to identify and secure any open zone.
Arming the System STAY Mode: Arms Perimeter Only, Entry Delay On • Used when you want to arm the system with persons staying inside (or if you have pets that are moving throughout the premises). • The door & window sensors are armed, but interior motion detectors are disarmed. •...
Arming the System (Continued) Arming Commands Before arming, close all perimeter doors and windows and make sure the Ready to Arm message is displayed. Mode Press these keys… Keypad Confirms By… • three beeps † security code + STAY STAY •...
Arming the System (Continued) Single Button Arming The “A”, “B”, “C”, and/or “D” keys on your keypad may have been programmed for single-button arming. Note that while it is not necessary to use a security code for arming (by using the Quick Arm method described previously), a security code must always be used when manually disarming the system.
Keyswitch Using the Keyswitch Your system may be equipped with a keyswitch for use when arming and disarming. Red and green lights on the keyswitch plate indicate the status of your system as follows: Green Light: Lights when the system is disarmed and ready to be armed (no open zones). If the system is disarmed and the green light is off, it indicates the system is not ready (one or more zones are open).
Disarming and Silencing Alarms Using the [OFF] key The OFF key is used to disarm the system, silence alarm and trouble sounds, and clear alarm memories. IMPORTANT: If you return and the main burglary sounder is on, DO NOT ENTER, but CONTACT THE POLICE from a nearby safe location.
Bypassing Protections Zones Using the BYPASS Key Use t his key when you want to arm your system with one or more zones intentionally unprotected. The system must be disarmed first. Vent Zones: Your system may have certain windows set as “vent” zones, which are automatically bypassed if left open when arming the system (you do not need to manually bypass them).
Bypassing Protection Zones (Continued) Quick Bypass If programmed, "Quick Bypass" allows you to easily bypass all open (faulted) zones without having to enter zone numbers individually. This feature is useful if, for example, you routinely leave certain windows open when arming at night. + [#] Alpha Display: BYPASS...
Chime Mode Using the Chime Mode CHIME mode alerts you to the opening of a perimeter door or window while the system is disarmed. When Chime mode is activated: • Three tones sound at the keypad whenever a perimeter door or window is opened. •...
Date and Time Viewing the Current Date and Time The master users can view the system time and date setting on an alpha keypad. Other users can view the date/time if a function key has been programmed to do so. + [#] + [6] [3] Alpha Display: ∗∗∗∗DISARMED∗∗∗∗...
Panic Keys Using Panic Keys Your system may have been programmed to use special keys to manually activate emergency (panic) functions as follows: This Function Sends This Signal* With This Sounding… Silent Alarm silent alarm no audible alarm; displays, “Press [∗] to show faults,” indicating that a silent alarm has been initiated.
Macro Key Programming & Usage About Macro Keys The “A”, “B”, “C” or “D” keys can be used to automatically activate a series of commands of up to 16 keystrokes, if programmed for this function. These keystrokes, as a group, are called “macros” and are stored in the system's memory.
Macro Key Programming and Usage (Continued) The keypad beeps to acknowledge your input and displays the command you entered (followed by “F”). 4. Enter the next command, followed by press/holding the “D” key for at least two seconds. The keypad beeps and displays the keystrokes entered so far. 5.
Using Device Commands About Device Commands Your system may be set up so that it can control certain lights or other devices. • Some devices may be automatically turned on or off by the system. • You may be able to override automatically controlled devices using the commands described below.
Paging Feature About Automatic Paging Your system may be set up to automatically send messages to several pagers (4 pagers for VISTA-20P Series, 2 pagers for VISTA-15P Series) as certain conditions occur in your system. • The following events can be programmed by your installer to be sent to the pagers: arming and disarming , alarms, and trouble conditions.
Paging Feature (Continued) About Manual Paging Your system may be set up so you can manually send a message to up to four (VISTA-20P Series) or two (VISTA-15P Series) pagers. • Your installer programs the paging function key and the pager phone numbers. •...
Security Codes & Authority Levels About Security Codes Your installer assigned a master code that is used to perform all system functions. In addition, other security codes can be assigned for use by other users (VISTA-20P Series provides 47 additional codes; VISTA-15P Series provides 31 additional codes). •...
Security Codes & Authority Levels (Continued) How to Assign Security Codes and User Attributes The following lists the various command strings for adding security codes and attributes. Refer to the User Setup chart at the back of this manual for factory defaults of user attributes and to keep a record of user programming.
Accessing Other Partitions (Vista-20P) About Accessing Partitions (VISTA-20P) (GOTO Command and Multi-Partition Arming) Each keypad is assigned a default partition for display purposes, and will show only that partition's information. • If the user is authorized, a keypad in one partition can be used to perform system functions in the other partition by using the GOTO command.
Accessing Other Partitions (Continued) Using the GoTo Command (VISTA-20P) If the user is authorized, a keypad in one partition can be used to perform system functions in the other partition by using the GOTO command. • You must use an Alpha keypad to access another partition. •...
Accessing Other Partitions (Continued) Common Zone Operation (VISTA-20P) Your system may have been set up to use a common zone, which is an Ask your installer if a area shared by users of both partitions, such as a foyer or lobby. If so, "common zone"...
Scheduling About Scheduling The system provides end-user schedules (programmable by master/installer only), which can control various types of events. • Each schedule causes a defined event to start and stop (when appropriate) at a specified time. • Schedules can be set to automatically repeat at various intervals. •...
Page 38
Scheduling (Continued) 5. For event number “02,” enter the access group number. GROUP NUMBER Otherwise, this prompt is skipped. Press [∗] to continue to the “Start” prompt below. 6. For event numbers “03-07,” enter the partition number PARTITION to be armed or disarmed. 0 = arm all;...
Event Logging Procedures About Event Logging The system records various events in a history log, which can be viewed by the master user on an Alpha Display keypad. • The Event Log holds up to 100 (VISTA-20P Series) or 50 (VISTA-15P Series) events. •...
Page 40
Event Logging Procedures (Continued) Code Definition Code Definition R401 - Armed AWAY, MAXIMUM Alarm, Expansion Module E401 - Disarmed ECP Module cover tamper Schedule Arm/Disarm AWAY Silent Burglary Cancel by User Alarm, 24-Hour Auxiliary/Monitor Remote Arm/Disarm (Downloading) zone Quick Arm AWAY Carbon Monoxide Keyswitch Arm/Disarm AWAY AC Power...
Testing the System About Testing the System Using the Test mode allows each protection point to be checked for proper operation. Testing should be conducted weekly to ensure proper operation. • The keypad sounds a single beep about every 30 seconds as a reminder that the system is in the Test mode.
Trouble Conditions "Check" and he word CHECK on the keypad's display, accompanied by a "Battery" Displays "beeping" at the keypad, indicates a trouble condition in the system. To silence the beeping for these conditions, press any key. 1. A display of "CHECK" and one or more zone numbers indicates that a problem exists with the displayed zone(s) and requires your attention.
Page 43
Trouble Conditions (Continued) Words or letters in parentheses ( ) are those that are displayed on Fixed-Word Display keypads. Other Trouble COMM. FAILURE Indicates that a failure has occurred in (or FC) the telephone communication portion of Displays your system. CALL FOR SERVICE. SYSTEM LO BAT Indicates that a low system battery (or BAT with no...
Page 44
Trouble Conditions (Continued) AC LOSS The system is operating on battery power Other Trouble (or NO AC) Displays only due to an AC power failure. (Continued) If only some lights are out on the premises, check circuit breakers and fuses and reset or replace as necessary.
Maintaining Your System Taking Care of The components of your security system are designed to be as maintenance-free as possible. However, to make sure that your system Your System is in reliable working condition, do the following: 1. Test your system weekly . 2.
Fire Alarm System THIS SECTION APPLIES ONLY TO RESIDENTIAL SYSTEMS General Your fire alarm system (if installed) is on 24 hours a day, for continuous protection. In the event of an emergency, the strategically located smoke and heat detectors will sound their alarms and automatically send signals to your system, triggering a loud, interrupted pulsed sound* from the Keypad(s) and any external sounders.
Page 47
Fire Alarm System (Continued) THIS SECTION APPLIES ONLY TO RESIDENTIAL SYSTEMS Manually 1. Should you become aware of a fire emergency before your smoke or heat detectors sense the problem, go to your nearest keypad and Initiating manually initiate an alarm by pressing the panic key assigned for FIRE a Fire Alarm emergency for 2 seconds (see below).
Page 48
Fire Alarm System (Continued) THIS SECTION APPLIES ONLY TO RESIDENTIAL SYSTEMS National Fire Protection Association Recommendations on Smoke Detectors With regard to the number and placement of smoke/heat detectors, we subscribe to the recommendations contained in the National Fire Protection Association's National Fire Alarm Code (NFPA 72) noted below.
Page 49
Fire Alarm System (Continued) THIS SECTION APPLIES ONLY TO RESIDENTIAL SYSTEMS Emergency Evacuation Establish and regularly practice a plan of escape in the event of fire. The following steps are recommended by the National Fire Protection Association: 1. Position your detector or your interior and/or exterior sounders so that they can be heard by all occupants.
Quick Guide to Basic System Functions FUNCTION PROCEDURE COMMENTS Check Zones Press READY key. View faulted zones when system not ready. Arm System Enter code. Press arming key desired: Arms system in mode selected. (AWAY, STAY, NIGHT-STAY, MAXIMUM, INSTANT) Quick Arm Press #.
Summary of Audible/Visual Notifications Fixed-Word Display Keypads SOUND CAUSE DISPLAY LOUD, FIRE ALARM or CO ALARM (CO: FIRE or ALARM (for CO) is displayed; zone keypad/detector only; not external number of zone in alarm is displayed. If a fire INTERRUPTED * sounder) alarm is manually activated, zone number 95 Keypad &...
Summary of Audible/Visual Notifications (Continued) Alpha Display Keypads SOUND CAUSE DISPLAY LOUD, FIRE ALARM or CO ALARM (CO: FIRE or ALARM (for CO) is displayed; descriptor INTERRUPTED* keypad/detector only; not external of zone in alarm is displayed. If a fire alarm is Keypad &...
Regulatory Statements and Warnings FEDERAL COMMUNICATIONS COMMISSION STATEMENTS The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User's Manual. Unauthorized changes or modifications could void the user's authority to operate the equipment. CLASS B DIGITAL DEVICE STATEMENT This equipment has been tested to FCC requirements and has been found acceptable for use.
Page 54
Regulatory Statements (Continued) Industry Canada (continued) Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations.
System Features Log Features Comments Exit Delay Part. 1: Part. 2 Entry Delay 1 Part. 1: Part. 2 Entry Delay 2 Part. 1: Part. 2 NIGHT-STAY Zones Zones: Quick Arm Quick Bypass Automatic Paging users: Keyswitch Arming Arm AWAY: steady flash (circle type of LED lighting) Arm STAY:...
Page 56
System Features Log (Continued) User Setup † The following chart will help keep track of system users. Copies should be distributed to the partition 1 and † partition 2 (if applicable) masters for their records. To program a user attribute: Enter system/partition* master code + [8] + user no.
Page 57
System Features Log (Continued) User Setup (cont’d) Enter system/partition master code + [8] + user no. + “#” command listed in column heading. User User User’s Part(s). Security Auth. Access RF Zone Pager Name (system master only) Code Level Group Number on/off [#] [3] + part(s) + [#]...
Page 58
System Features Log (Continued) Schedules*: master code + [#] + [6] [4] Event Device No. Group No. Partition Start Stop Repeat Random Time/ Time/ (see list below) for “01” events: for “02” events: for “04-06” events: (1-4) (yes/no) enter 1-8 enter 1, 2, or 3 (see device list below) Events:...
Page 59
OWNER’S INSURANCE PREMIUM CREDIT REQUEST This form should be completed and forwarded to your homeowner’s insurance carrier for possible premium credit. A. GENERAL INFORMATION: Insured’s Name and Address: Insurance Company: Policy No.: VISTA-20P / VISTA-15P Other _______________________________________________ (circle the appropriate model number) Type of Alarm: Burglary Fire...
Page 60
OWNER’S INSURANCE PREMIUM CREDIT REQUEST (cont.) E. SMOKE DETECTOR LOCATIONS Furnace Room Kitchen Bedrooms Attic Basement Living Room Dining Room Hall F. BURGLARY DETECTING DEVICE LOCATIONS: Front Door Basement Door Rear Door All Exterior Doors Floor Windows All windows nterior locations All Accessible Openings, Including Skylights, Air Conditioners and Vents G.
Page 61
SERVICING INFORMATION Your local authorized service representative is the person best qualified to service your alarm system. Arranging some kind of regular service program with him is advisable. Your local service representative is: Name: Address: Phone: – 57 –...
Limitations of this System WARNING! THE LIMITATIONS OF THIS ALARM SYSTEM While this system is an advanced design security system, it does not offer guaranteed protection against burglary or other emergency. Any alarm system, whether commercial or residential, is subject to compromise or failure to warn for a variety of reasons.
Page 64
Exceptions to Warranty with Respect to Honeywell Home Products listed below: Hardwire Contacts and PIRs – Seller warrants parts for hardwire contacts and PIRs in accordance with the terms of the above limited warranty for a period of five (5) years from the manufacture date code.
Need help?
Do you have a question about the ADEMCO VISTA-20PSIA and is the answer not in the manual?
Questions and answers