1. Before installation.
1.1 Please check water pressure before operating this unit.
Minimum water pressure : 0.02 MPa (0.21 Bar).
Maximum water pressure : 0.34 MPa (3.39 Bar).
Please follow the picture below to check water pressure. Water shall overflow at the end of the tube
within 2.3 meters above the faucet.
2. Installation the unit.
2.1 Preparing installation area.
The unit must be mounted to the wall in a vertical position only. (See in the picture)
Leave this unit away from the wall for both sides more than 200 millimeters.
The minimum height of 1.5 meters to the lower edge of the unit must be observed.

WIRING DIAGRAM

INSTALLATION ADVICE

Fig. 6
About 2.3 meters
Fig. 5
Fig. 7
5
1.5 meters