Table 1-11. Port Auto-Disablement Decision Table
IOM Slot A1
Empty
Empty
Empty
Dual Port
Dual Port
Dual Port
Quad or Greater
Port
Quad or Greater
Port
Quad or Greater
Port
Mezzanine Cards
M610x Only
The M610x blade supports two mezzanine cards. Mezzanine cards can be
installed in both the slots on the midplane interface card.
NOTE:
M610x is a full-height blade but supports only two mezzanine cards in the
expansion bay. The two mezzanine slots on the M610x system board
(MEZZ2_FAB_B and MEZZ1_FAB_C) are reserved for the mezzanine interface card.
See "Mezzanine Interface Card (M610x Only)" on page 196.
50
About Your System
IOM Slot A2
Empty
Dual Port
Quad or Greater
Port
Empty
Dual Port
Quad or Greater
Port
Empty
Dual Port
Quad or Greater
Port
NIC3 and NIC4
(Enabled/Disabled)
Enabled
Disabled
Enabled
Disabled
Disabled
Enabled
Enabled
Enabled
Enabled
Port Auto-
Disablement
Inactive
Active
Inactive
Active
Active
Inactive
Inactive
Inactive
Inactive