Table 1-26. Blade Messages
Message
Alert: DIMM_[m]
and DIMM_[n] must
be populated with
a matched set of
DIMMs if more than
1 DIMM is present.
The following
memory DIMMs have
been disabled.
Alert! Node
Interleaving
disabled! Memory
configuration does
not support Node
Interleaving.
Alert! Redundant
memory disabled!
Memory
configuration does
not support
redundant memory.
Alert! Redundancy
was previously
lost. Power cycle
required to
reconfigure
redundant memory.
(continued)
Causes
The installed memory
configuration is invalid.
The installed memory
configuration does not
support node interleaving.
The installed memory
configuration does not
support redundant
memory.
Memory error.
Corrective Actions
Ensure that the memory
modules are installed in
matched pairs. See "System
Memory" on page 159.
Install a memory
configuration that supports
node interleaving. See
"System Memory" on
page 159.
Install a memory
configuration that supports
redundant memory. See
"System Memory" on
page 159.
Disable the Redundant
Memory option in the
System Setup program. See
"Using the System Setup
Program
and UEFI Boot Manager" on
page 127.
Power cycle the blade.