ESWCH System Messages

ESW-1001
Message
<timestamp>, [ESW-1001], <sequence-number>,, ERROR, <system-name>, Switch is not
in ready state - Switch enable failed switch status= 0x<switch status>, c_flags =
0x<switch control flags>.
Probable Cause
Indicates that the switch enable has failed.
Recommended
If the message persists, run the supportFtp command (as needed) to set up automatic FTP
Action
transfers; then run the supportSave command and contact your switch service provider.
Severity
ERROR
ESW-1002
Message
<timestamp>, [ESW-1002], <sequence-number>,, INFO, <system-name>, Security
violation: Unauthorized device <wwn name of device> tries to flogin to port <port
number>.
Probable Cause
Indicates that the device is not present in the authorized profile list.
Recommended
Verify that the device is authorized to log in to the switch. If the device is authorized, first run the
Action
secPolicyDump command to verify whether the specified device world wide name (WWN) is listed. If
it is not listed, run the secPolicyAdd command to add this device to an existing policy.
Severity
INFO
ESW-1003
Message
<timestamp>, [ESW-1003], <sequence-number>,, ERROR, <system-name>, Slot ENABLED
but Not Ready during recovery, disabling slot = <slot number>(<return value>).
Probable Cause
Indicates that the slot state has been detected as inconsistent during failover or recovery.
Recommended
On a Brocade 8000 switch, restart or power cycle the switch.
Action
Severity
ERROR