Basic Configuration Using the Command-Line Interface
Configuring a Channelized T3 Feature Card
The channelized T3 (CT3) feature card offers 28 individual T1 channels (bundled in the T3 line) for
serial transmission of data. The channelized T3 link supports the maintenance data link channel in C-Bit
parity mode and also payload and network loopbacks. The T1 channels multiplexed in the channelized
T3 link support facilities data link (FDL) in extended super frame (ESF) framing.
Additionally, you can allocate your T1 channels as described in the
Cards" section on page
Controller Numbering
The channelized T3 controller numbering convention is slot/port in CLI commands. Feature card slot
numbering starts from the motherboard and works up from left to right. Slot 0 is reserved for the
motherboard. Feature card slots are numbered sequentially from 1 to 7. Port number value is always 0.
Under the channelized T3, the T1 controller numbering convention is slot/port:channel in CLI
commands. Port numbering values range from 1 to 28.
Configure
Command
Step 1
AS5400> enable
Password: password
AS5400#
Step 2
AS5400# configure terminal
Enter configuration commands, one per line.
End with CNTL/Z.
AS5400(config)#
Step 3
AS5400(config)# controller t3 1/0
AS5400(config-controller)#
Step 4
AS5400(config-controller)# framing c-bit
Step 5
AS5400(config-controller)# clock source
line
Step 6
AS5400(config-controller)# cablelength 450
8.
Cisco AS5350XM and Cisco AS5400XM Universal Gateways Software Configuration Guide
Configuring a Channelized T3 Feature Card
"Configuring T1 and E1 Feature
Purpose
Enters enable mode. Enters the password. You are
in enable mode when the prompt changes to
or
.
AS5350#
AS5400#
Enters global configuration mode. You are in
global configuration mode when the prompt
changes to
AS5350(config)#
AS5400(config)#.
Enters controller configuration mode to configure
your T3 controller for slot 1 port 0. Slot values
range from 1 to 7. Port number is always 0.
Enters the telco framing type: c-bit or m23.
Enters line clock source: internal or line.
Enters your cable length: values range from 0 to
450 feet.
or
11