Configuring the Communication Settings <OPTION>
The camera can be operated remotely by connecting a hard disk recorder or controller as a communication device. You need to
configure the conditions for the communication to function.
CAMERA
PRESET POSITION
AUTO MODE
AUTO RETURN
ALARM
PASSWORD
LANGUAGE
·OPTION
·OPTION
PRESET
MENU
Setting Protocol for Camera Controller <CONTROL>
1
Select <CONTROL> and specify the protocol for
controlling the camera.
·CONTROL
COAX : Coaxial superposition (SANYO: using coaxial cable)
• SSP, Hi-speed SSP and PELCO-C are supported.
Switching among the three is automatic.
485S : RS-485 (SANYO)
• Both SSP and Hi-speed SSP are supported. Switching
between the two is automatic.
485P : RS-485 (PELCO-D)
45
For accessing the main menu, see pages 7 – 8.
SET
y
1
y
SEQ
y
SET
OFF
SET
y
R
SET
y
SET
y
SET
y
OFF
END
OPTION
TITLE
OFF
PRIVACY MASK
SET
y
·CONTROL
COAX
ADDRESS
1
ALARM LINE OUT
OFF
OPTION
TITLE
OFF
PRIVACY MASK
SET
·CONTROL
COAX
ADDRESS
1
R
ALARM LINE OUT
OFF
PRESET
OFF
MENU
BACK
2
For advanced settings (485S or 485P), press the
SET button.
RThe "CONTROL SETTING" screen appears.
• Advance to step
3
Select <BAUD RATE> and specify the
communication speed.
·BAUD RATE
• Select from: 19200, 9600, 4800, 2400
y
5
if you have selected "COAX".
CONTROL SETTING
·BAUD RATE
TERMINATE
19200
OFF