System Administration Using The Web Browser; Logging Into The Web Browser; Upgrading The Ultrakey Touch Firmware - Honeywell UltraKey Touch HJC4000 Installation And User Manual

Dvr and ptz keyboard controller
Table of Contents

Advertisement

System Administration Using the Web Browser

Logging into the Web Browser

Upgrading the UltraKey Touch Firmware

Document 800-06554 Rev C
02/11
3.
Press Slider_Up/Down keys and press Ent to select one or all of the following test
options:
Key: When you press a key, the key value and its
state is displayed on LCD.
Joystick: When you move the joystick, values
which present the PTZ (pan, tilt, zoom) positions
of the joystick are displayed on the LCD.
SerialPort: Confirms that the controller serial port
is functioning.
Slider: When you rotate the touch pad, specific
values are displayed on the LCD.
4.
Press Alt > Clr to exit from these test menus.
1.
If not already done, navigate to, or copy and paste, the applicable IP address into
your web browser:
LAN connections: for example, http://192.168.1.9.
Crossover cable connections - static address: http://192.168.1.9, and it must be
consistent with the UltraKey Touch IP address (refer to network configuration).
In the User Name field enter Administrator (case sensitive).
2.
In the Password field enter 1234 (default).
3.
Click Login.
1.
Log into the web browser.
2.
From the top menu, click the Upgrade tab.
The warning message Please make sure the network connection is
connected during system upgrading displays (see
3.
Click OK. The Software Upgrade menu opens.
4.
Select a Folder from the drop-down list: Application, Kernel, or File System.
5.
In the Select File field, click Browse. Navigate to the file and click OK.
6.
Click Send to start the upgrade process.
UltraKey Touch Installation and User Guide
Device Test:
Key
Device Test:
Joystick
Device Test:
SerialPort
Device Test:
Slider
Figure
5-1).