5. API for Acquiring/Changing Parameters of VN-E4 _

Acquiring Log

Format
Response
Interpretation
Allowed user
/api/param?system.log
Return the following information. These information will be initialized upon turning off the power of VN-E4.
Response examples on the number of seconds after startup, alarm log information, motion detect log, list of
clients currently acquiring alarm, clients currently sending audio data, and clients currently using pass-
through.
system.log=&200 OK
system alive time: 2142sec
Alarm Detect 1 ( total 2 times )
2005/07/01 11:26:30 ( make )
2005/07/01 11:26:29 ( break )
Alarm Detect 2 ( total 2 times )
2005/07/01 11:26:30 ( make )
2005/07/01 11:26:29 ( break )
Alarm Detect 3 ( total 2 times )
2005/07/01 11:26:30 ( make )
2005/07/01 11:26:29 ( break )
Alarm Detect 4 ( total 2 times )
2005/07/01 11:26:30 ( make )
2005/07/01 11:26:29 ( break )
Motion Detect 1 ( total 2 times )
2005/07/01 11:26:30
2005/07/01 11:26:29
Motion Detect 2 ( total 2 times)
2005/07/01 11:26:30
2005/07/01 11:26:29
Motion Detect 3 ( total 2 times )
2005/07/01 11:26:30
2005/07/01 11:26:29
Motion Detect 4 ( total 2 times )
2005/07/01 11:26:30
2005/07/01 11:26:29
Alarm Monitor ( total 2 clients )
2005/07/01 11:26:30 ( 136.198.34.14 )
2005/07/01 11:26:29 ( 10.0.0.1 )
Serial Passthrough ( total 2 clients )
2005/07/01 11:26:30 ( 1 136.198.34.14 ) <----- Serial port no. and client's IP address
2005/07/01 11:26:29 ( 2 10.0.0.1 )
Audio Client ( total 1 clients )
2005/07/01 11:26:30 ( 136.198.34.14 )
Acquire the VN-E4 log.
admin
5.15. Acquiring Status
<----- No. of seconds after startup
<----- Alarm input 1ch
(Blank in the case of 0 times)
<----- Up to the latest 10 line
<----- Up to the latest 10 line
<----- Motion detect 1ch
(Blank in the case of 0 times)
<----- Up to the latest 10 lines
<----- Up to the latest 10 lines
<----- Clients currently acquiring alarm
(Blank in the case of 0 clients)
<----- Up to 4
<----- Clients currently using pass-through
(Blank in the case of 0 clients)
<----- Up to 2
<----- Clients currently sending audio data to E4
(Blank in the case of 0 clients)