Download Print this page

Kyocera CPR 12-15 Datasheet

Cathodic protection controllers

Advertisement

Quick Links

The Cathodic Protection Unit (CP) is a specialized power converter which provides DC
c u rrent to metal pipelines, storage tanks, bridges, or other exposed equipment to cancel the
e ffects of natural chemical corrosion. The CP operates directly from storage batteries com-
mon to photovoltaic systems and is equipped with a low voltage shut-down feature to pre-
vent battery damage. It is suitable for use in systems of either positive or negative gro u n d .
The Cathodic Protection Contro l l e r
is designed for tro u b l e - f ree serv i c e
in all environments and includes
many special features which make
it easy to operate and maintain in
the field. Power consumption and
heat generation are minimized in
the CP since efficient solid
state circ u i t ry is used instead of
ballast resistors typical of earlier
cathodic protection units. T h e
power circuit contains no moving
p a rts to wear out or break down.
Quality digital voltage and curre n t
meters provide output monitoring which facilitates field adjustment. This is easily
p e rf o rmed by inserting a small screwdriver through the faceplate. Recalibration can
be perf o rmed in minutes without special tools or meter equipment.
Since corrosion protection systems normally operate in remote, unattended sites, they
should be protected from the common effects that make them fail such as: lightning
e x p o s u re, battery damage, and short - c i rc u i t s. That's why every Kyocera Solar, Inc. CP
Unit includes lightning transient suppression, a low battery shut-down circuit and output
overload pro t e c t i o n. Our dual transient protection network will suppress electrical spikes
and surges that normally damage field equipment. If the storage batteries become
d i s c h a rged due to cloudy days or photovoltaic system failure, the CP Unit will automatically
shut down, preventing excessive discharge and protecting the battery from perm a n e n t
damage and costly re p l a c e m e n t. Our built-in circ u i t - b reaker prevents damage to the CP
and other components, should the output leads become shorted to one another. To help
Typical Negative
Protection System
reduce overall system cost, the CP includes
adjustable current and voltage outputs. S t a n d a rd
photovoltaic modules can be used and the CP
output adjusted to the desired level.
Current Load
C a reful matching of the array to the DC converter
is not re q u i re d. The CP Unit can pro v i d e :
1) Adjustable current output with fixed upper limit
2) Adjustable voltage output with fixed upper
CPR 12/24-15 and
C P R 1 2 / 2 4 - 4 0
CATHODIC PROTECTION
CONTROLLERS
on voltage output
O R
limit on current output.

Advertisement

loading

Summary of Contents for Kyocera CPR 12-15

  • Page 1 CPR 12/24-15 and C P R 1 2 / 2 4 - 4 0 CATHODIC PROTECTION CONTROLLERS The Cathodic Protection Unit (CP) is a specialized power converter which provides DC c u rrent to metal pipelines, storage tanks, bridges, or other exposed equipment to cancel the e ffects of natural chemical corrosion.
  • Page 2 CPR 12/24-15 and CPR 1 2 / 2 4 - 4 0 CATHODIC PROTECTION CONTROLLERS S t a n d a rd Feature s • Ideal for solar powered battery backed cathodic protection systems • User adjustable output voltage, current limit and half cell voltage re g u l a t i o n •...

This manual is also suitable for:

Cpr 12-40Cpr 24-15Cpr 24-40Cpr 12/24-15Cpr 12/24-40