MICOM Function and Description of Circuit
3. Sensor Resistance Characteristics Table
Measuring Temperature(°C)
-20° C
-15° C
-10° C
-5° C
0° C
+5° C
+10° C
+15° C
+20° C
+25° C
+30° C
+40° C
+50° C
➲ Allowance of sensor resistance is 5%.
➲ Measure resistance value of sensor after leaving it for more than 3 minutes (delay is required due
to sensing speed).
➲ Always use a digital tester! Analog testers have too great a margin of error.
➲ For the left compartment sensor, measure both ends of Nº. 1 and Nº. 2 after separating CON2
from the PCB Assembly. For the right compartment sensor, measure both ends of Nº. 1 and Nº. 2
of CON3. For the outside (ambient) sensor, measure both ends of Nº. 1 and Nº. 2 of CON5.
Left Sensor, Right Sensor
77 KΩ
60 KΩ
47.3 KΩ
38.4 KΩ
30 KΩ
24.1 KΩ
19.5 KΩ
15.9 KΩ
13 KΩ
11 KΩ
8.9 KΩ
6.2 KΩ
4.3 KΩ
33