LG GR-K20SVZ Technical Manual page 27

Kimchi storage
Hide thumbs Also See for GR-K20SVZ:
Table of Contents

Advertisement

MICOM Function and Description of Circuit
9) Keeping temperature compensation and too cold/too warm cut
compensation circuit
(1) Keeping temperature compensation
LED MODULE TYPE
GR-K16SLQ, GR-K18SLQ
➲ This is a circuit to input the temperature compensation level required for adjusting storage
temperature at the left or right compartment.
Left Compartment
(RCL)
➲ Temperature compensation table by adjustment of resistance value (difference value against
current temperature).
LEFT STORAGE
TEMPERATURE COMPENSATION
RIGHT STORAGE
TEMPERATURE COMPENSATION
Right Compartment
(RCR)
180 KΩ
56 KΩ
33 KΩ
18 KΩ
12 KΩ
10 KΩ
8.2 KΩ
5.6 KΩ
3.3 KΩ
2 KΩ
470 Ω
Temperature compensation value
+2.5° C
+2.0 ° C
+1.5 ° C
+1.0 ° C
+0.5 ° C
0 ° C
-0.5 ° C
-1.0 ° C
-1.5 ° C
-2.0 ° C
-2.5 ° C
28
LCD TYPE
GR-K20SVZ
LEFT STORAGE
TEMPERATURE COMPENSATION
RIGHT STORAGE
TEMPERATURE COMPENSATION
Remarks
Warmer
Standard temperature
Cooler