Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
Dell EMC Manuals
Storage
VMAX 400K
Site planning manual
Dell EMC VMAX 400K Site Planning Manual
Hide thumbs
1
2
Table Of Contents
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
page
of
100
Go
/
100
Contents
Table of Contents
Bookmarks
Table of Contents
Table of Contents
Figures
Tables
Preface
Typographical Conventions Used in this Content
Revision History
Chapter 1 Pre-Planning Tasks
Overview of Data Center Requirements
Tasks to Review
Before You Begin
Chapter 2 Delivery and Transportation
Delivery Arrangements
Moving up and down Inclines
Pre-Delivery Considerations
Shipping and Storage Environmental Requirements
Chapter 3 Specifications
Radio Frequency Interference
Recommended Minimum Distance from RF Emitting Device
Minimum Distance from RF Emitting Devices
Power Consumption and Heat Dissipation
Adaptive Cooling
Airflow
Typical Airflow in a Hot/Cold Aisle Environment
Airflow Diagram Key
Air Volume, Air Quality, and Temperature
Air Volume Specifications
Temperature, Altitude, and Humidity Ranges
Temperature and Humidity Range Recommendations
Maximum Air Volume
Environmental Operating Ranges
Temperature and Humidity
Air Quality Requirements
Shock and Vibration
Sound Power and Sound Pressure
Platform Shock and Vibration
Sound Power and Sound Pressure Levels, A-Weighted
Hardware Acclimation Times
Optical Multimode Cables
Open Systems Host and SRDF Connectivity
OM3 and OM4 Fibre Cables - 50/125 Micron Optical Cable
Chapter 4 Data Center Safety and Remote Support
Fire Suppressant Disclaimer
Remote Support
Chapter 5 Physical Weight and Space
Floor Load-Bearing Capacity
Raised Floor Requirements
Physical Space and Weight
Space and Weight Requirements
Chapter 6 Position Bays
System Bay Layouts
Adjacent Layouts, Single-Engine Array
Adjacent Layout, Single-Engine Array
Adjacent Layout Diagram Key
Adjacent Layouts, Dual-Engine Array
Adjacent Layout, Dual-Engine Array
Adjacent Layout Diagram Key
Dispersed Layouts, Single-Engine Array
Dispersed Layout, Single-Engine Array
Dispersed Layout, Dual-Engine Array
Dispersed Layout, Dual-Engine, Front View
Adjacent and Dispersed (Mixed) Layout
Adjacent and Dispersed (Mixed) Layout, Single-Engine Array
Dimensions for Array Layouts
Adjacent and Dispersed (Mixed) Layout, Dual-Engine Array
Layout Dimensions, VMAX3 Family
Tile Placement
Caster and Leveler Dimensions
Placement with Floor Tiles, VMAX3 Family
Caster and Leveler Dimensions
Caster and Leveler Dimensions Diagram Key
Chapter 7 Power Cabling, Cords and Connectors
Power Distribution Unit
Power Distribution Unit (PDU) Without Installed Wire Bales, Rear View
Power Distribution Unit (PDU) with Installed Wire Bales, Rear View
Wiring Configurations
Single-Phase, Horizontal 2U PDU Internal Wiring
Three-Phase (Delta), Horizontal 2U PDU Internal Wiring
Three-Phase (Wye), Horizontal 2U PDU Internal Wiring
Power Interface
Customer Input Power Cabling
Best Practices: Power Configuration Guidelines
Power Extension Cords, Connectors and Wiring
Single-Phase
Extension Cords and Connectors Options - Single-Phase
Single-Phase: E-PW40U-US
Single-Phase: E-PW40URUS
Single-Phase: E-PW40UIEC3
Single-Phase: E-PW40UASTL
Single-Phase: E-PW40L730
Three-Phase Wye (International)
Extension Cords and Connectors Options - Three-Phase International (Wye)
Flying Leads, Three-Phase, International: E-PC3YAFLE
Three-Phase, International: E-PCBL3YAG
Three-Phase North American Delta
Extension Cords and Connectors Options - Three-Phase North American (Delta)
Three-Phase, North American, Delta: E-PCBL3DHR
Three-Phase, North American, Delta: E-PCBL3DHH
Three-Phase Wye (Domestic)
Extension Cords and Connectors Options - Three-Phase Wye, Domestic
Three-Phase, Domestic (Black and Gray): E-PCBL3YL23P
Chapter 8 Grounding Racks
Grounding Requirements
Grounding a Single Bay
Location of Cabinet Ground Lugs
Chassis to Chassis Grounding
Chapter 9 Third Party Racking Option
Computer Room Requirements
Customer Rack Requirements
Customer Rack Dimension Requirements
Third Party Racks with Vertical Pdus - RPQ Required
Requirements for Third Party Racks with Vertical Pdus (Rear-Facing)
Requirements for Customer Rack with Rear-Facing, Vertical Pdus
Requirements for Third Party Racks with Vertical Pdus (Inward-Facing)
Requirements for Third Party Rack with Inward-Facing, Vertical Pdus
Chassis to Chassis Grounding
Chapter 10 Optional Kits
Overhead Routing Kit
Dispersion Kits
Top Routing Cover
Overhead Routing Models
Dispersion Kit Model Numbers
Securing Kits
Gridrunner Kit and Customer-Supplied Cable Trough
Securing Kit Models
Bottom Routing Model
Appendix Best Practices for AC Power Connections
Best Practices for AC Power Connections Appendix
Best Practices Overview for AC Power Connections
Two Independent Customer-Supplied Pdus
Selecting the Proper AC Power Connection Procedure
Procedure Options for AC Power Connection
Procedure A: Working with the Customer's Electrician Onsite
Procedure A, Task 1: Customer's Electrician
Circuit Breakers on - AC Power Within Specification
Circuit Breakers off - no AC Power
Procedure A, Task 2: Dell EMC Customer Engineer
System Bay Power Tee Breakers (off = Pulled Out)
Connecting AC Power, Single-Phase
Connecting AC Power, Three-Phase
Power Zone Connections
Procedure A, Task 3: Customer's Electrician
Procedure B: Verify and Connect
Procedure C: Obtain Customer Verification
PDU Labels
VMAX3 Family Label Part Numbers, EMC Racks
PDU Label , Single-Phase and Three-Phase
Label Placement- Customer PDU Information
Input Power Requirements - Single-Phase, North American, International, Australian
Input Power Requirements - Three-Phase, North American, International, Australian
AC Power Specifications
Advertisement
Quick Links
1
Chapter 5 Physical Weight and Space
2
Power Cabling, Cords and Connectors
Download this manual
™
™
Dell EMC
VMAX3
Family Site Planning
Guide
VMAX 100K, VMAX 200K, and VMAX 400K
Revision 12.0
April 2020
Table of
Contents
Previous
Page
Next
Page
1
2
3
4
5
Advertisement
Table of Contents
Need help?
Do you have a question about the VMAX 400K and is the answer not in the manual?
Ask a question
Questions and answers
Related Manuals for Dell EMC VMAX 400K
Storage Dell EMC Unity 480/F Installation And Service Manual
(126 pages)
Storage Dell EMC Unity 480 Hardware Information Manual
All flash and hybrid (26 pages)
Storage Dell EMC Unity 480 Quick Start Manual
(8 pages)
Storage Dell EMC Unity Series Installation Manual
(70 pages)
Storage Dell EMC 40U-P Unpacking And Setup Manual
Cabinet (16 pages)
Storage Dell EMC DLm8500 VMAX Physical Planning Manual
Disk library for mainframe (50 pages)
Storage Dell EMC VMAX 100K Site Planning Manual
(100 pages)
Storage Dell EMC VMAX 200K Site Planning Manual
(100 pages)
Storage Dell EMC VMAX3 Series Site Planning Manual
(100 pages)
Storage Dell EMC Data Domain DD6300 Installation Manual
(36 pages)
Storage Dell EMC PowerScale F200 Installation Manual
(19 pages)
Storage Dell EMC PowerVault ME4 Series Deployment Manual
(91 pages)
Storage Dell EMC BOSS-S1 User Manual
Boot optimized server storage (28 pages)
Storage Dell EMC ECS D Series Hardware Manual
Elastic cloud storage (114 pages)
Storage Dell EMC VxRail E Series Owner's Manual
Vxrail appliances on poweredge servers (42 pages)
Storage Dell EMC PowerProtect DD9900 Installation Manual
(96 pages)
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL
Need help?
Do you have a question about the VMAX 400K and is the answer not in the manual?
Questions and answers