30" & 36" DUAL FUEL RANGE INSTALLATION INSTRUCTIONS
5.

Electrical Connection to the Range

(US models only)
This appliance is manufactured with the neutral terminal
connected to the range.
You may not ground the oven
through the neutral (white) wire if oven is used in
a new branch circuit installation (1996 NEC), mobile
home, recreational vehicle, or where local codes do
not permit grounding through the neutral (white)
wire. When grounding through the neutral (white)
wire is prohibited, you must use a 4-wire power
supply cable. See Section 5B. Failure to heed this
warning may result in electrocution or other serious
personal injury.
While connecting range, do not
loosen the nuts which secure the terminal block
to the range. Electrical failure or loss of electrical
connection may occur.
5.A
Three Conductor Wire Connection
to the Range
(The 3-conductor cord or cable must be replaced with
a 4-conductor cord or cable where grounding through
the neutral conductor is prohibited in new installations,
mobile homes, recreational vehicles or in other areas
where local codes do not permit neutral grounding)
If local codes permit connection of the frame
grounding conductor to the neutral wire of the
power supply cord (Figure 9):
1. Remove the screws
at the lower end
of the rear wire
access panel or
cover, then remove
the access cover or
lift the lower part
of the access panel
to expose range
terminal connection
block (Fig. 7 or 8).
Pressure regulator
Risk of fire or electrical shock exists
if an incorrect size range cord kit is used, if the
Installation Instructions are not followed, or if the
strain relief bracket is discarded.
(Model with Electric Oven and Gas Cooktop)
Rear wire
access cover
location
Figure 7 - 30" Range
Rear wire
access panel
Figure 8 - 36" Range
2. Remove the 3 loose nuts on the terminal block using
3/8" nut driver or socket.
3. Connect the neutral white wire of the power supply
cord to the center silver-colored terminal of the
terminal block, and connect the other wires to the
outer terminals. Match terminal and power supply
wires by color.
4. Replace the 3 nuts on the terminal block (Figure 9).
5. Replace the rear access cover or panel using the
screws removed on step 1.
Three Conductor or Wire Connection to Range