Honeywell HW1000i - Portable Inverter Generator Owner's Manual page 26

Inverter generator
Hide thumbs Also See for HW1000i - Portable Inverter Generator:
Table of Contents

Advertisement

Available languages

Available languages

Engine Oil
Engine Oil
Place the oil pan, or other container suitable for hold-
6.
ing engine oil, in front of the generator.
FIGURE 23: Oil Drain Pan
Using a clean cloth, wipe around the oil fill cap area to
7.
remove dirt and debris.
Remove the oil fill cap.
8.
FIGURE 24: Oil Fill Cap Removal
20
www.honeywellgenerators.com
Attach the oil drain pipe (do not over tighten) and tilt
9.
the generator allowing the oil to completely drain into
the oil pan.
FIGURE 25: Drain Oil
Generator is heavy! Obtain assistance to lift the
generator to avoid back or other bodily injury.
Return the unit to the upright position.
10.
Remove the oil drain pipe.
11.
Using a clean cloth, wipe around the oil fill cap area to
12.
remove dirt and debris.
Fill the oil fill container (included) with the appropriate
13.
amount and type of new (unused) oil. (See Figure 17
for recommended oil type.)
Oil Capacity [qt / ml]
TABLE 5. Engine Oil Capacity
Slowly pour oil into the oil fill hole. DO NOT OVER-
14.
FILL.
FIGURE 26: Adding Engine Oil
HW1000i / HW2000i Inverter Generator Owner's Manual
HW1000i
HW2000i
0.26 / 250
0.48 / 450

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hw2000i

Table of Contents