Installation and
user manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 5S 1600 and is the answer not in the manual?

Questions and answers

Summary of Contents for Eaton 5S 1600

  • Page 1 EATON 5S 850/1200/1600 Installation and user manual...
  • Page 2 Packaging EATON 5S Caution! Before installing the Eaton 5S, read the booklet 3 containing the safety instructions to be respected. Then follow the instructions given in this manual 2 . 614-06819-00...
  • Page 3: Quick Start

    Quick start 1200 / 1600 614-06819-00...
  • Page 4: Battery Change

    • The battery elements must be replaced exclusively by qualified personnel (risk of electrocution), with new elements approved by Eaton to ensure correct operation of the UPS. • The battery must be disposed of in accordance with applicable regulations. To remove the battery elements, shut down the UPS (button 6 OFF), remove the power cord and proceed as indicated in page 4 "Battery change".
  • Page 5: Technical Characteristics

    Technical characteristics Eaton 5S 1200 1600 • UPS power 850 VA / 120 VA / 1600 VA / 510 W 750 W 1000 W • Nominal input voltage 185 V - 285 V, adjustable to 150 V - 285 V • Input frequency 50/60 Hz (46 - 70 Hz working range) • Voltage/frequency of battery backup...
  • Page 6: Operating Conditions

    1. Operating conditions • This product is an Uninterruptible Power Supply (UPS) for computers and their peripherals, television sets, stereo systems and video recorders... It must not be used to supply other electrical equipment (lighting, heating, household appliances, etc.). • UPS can be installed in horizontal, vertical position, or placed in Rack 2U (optional kit). 2.
  • Page 7 Optional USB connection: The UPS device can be connected to the computer using the USB cable 5 supplied. The software is available on the CD-ROM 5 or Eaton UPS Companion software is downloadable from powerquality.eaton.com (see figure C). Register for the warranty on powerquality.eaton.com.
  • Page 8: Ups Setting Through The Lcd

    6. UPS setting through the LCD Release scroll down button to select menu Output voltage Input voltage EcoControl Alarm tolerance (184 - 264 V) (161 - 284 V) Example of setting Save the new value LCD shut off if any button inactive for 3 minutes. 7.
  • Page 9: Lightning Protection

    6 . Shutdown of the battery backup outlets 19 Press button 6 for more than two seconds. 8. Troubleshooting (For further information, visit the www.powerquality.eaton.com site or contact after-sales support.) Problem Diagnostic Solution • The battery backup outlets • Button...