Samsung AVXWHH028 series Service Manual

Samsung AVXWHH028 series Service Manual

System air conditioner
Table of Contents

Advertisement

SERVICE
AIR CONDITIONER
Refer to the service manual in the GSPN(see the rear cover) for the more information.
SYSTEM AIR CONDITIONER
INDOOR UNIT
AVXC1H022/028/036E✳
AVXC2H056/071E✳
AVXC4H045/056/071/090/112/128/140E✳
AVXCMH028/032/056/060E✳
AVXDDH045/056/071/090E✳
AVXDHH112/128/140E✳
AVXDLH071/090/112/128/140E✳
AVXDBH022/028/036/056/071E✳
AVXDSH022/028/036/040/045/056/071/090/112/128/140E✳
AVXDUH071/112/128/140E✳
AVXWPH022/028/036/045/056/071E✳
AVXWHH028/036/045/056/071E✳
AVXWVH028/036/056/071E✳
AVXTFH056/071E✳
OUTDOOR UNIT
mini DVM : RVXMHF040/050E✳
:
RVXMHF050/060G✳
DVM
Plus2: RVXVHT080/100/120/140G✳
:
RVXFHT080/100/120/140G✳
DVM HR2 : RVXVRT080/100G✳
Manual
THE FEATURE OF PRODUCT
I
Available to unit with the various
indoor units.
– Applicable the various indoor unit types and
capacity.
I
Easy maintenance and installation
– Minimized shipping space.
– Reduction of unit weight.
I
Various Control System
I
Variable Scroll Comp. is applied
I
Overcomes the limit of connection
place of indoor unit.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AVXWHH028 series and is the answer not in the manual?

Questions and answers

Summarization of Contents

Precautions
1-1 Safety Precautions
Safety precautions for unit installation, focusing on R410A refrigerant.
1-2 Warning
Warnings about installation hazards like electric shock, fire, and injury.
1-3 Caution
Cautions regarding earthing, duct installation, drain pipes, and installation locations.
Product Specifications
2-1 The Feature of Product
Explains DVM technology, digital scroll compressor, and its benefits.
2-2-1 Indoor Unit Specifications
Product specifications for various indoor unit types.
2-2-2 Outdoor Unit Specifications
Product specifications for various outdoor unit types.
2-2-3 Accessory List
Lists accessories such as Refnet Joints, Headers, and Distributor Kits.
Alignment and Adjustments
3-1 Error mode and check method
Indoor unit LED lamp display and error detection methods for various unit types.
3-2 Self Diagnosis by Outdoor Unit Error Display
Outdoor unit error display methods and sequences for diagnosing issues.
3-3 Setting Option Setup Method
Method for setting option codes via remote controller using specific steps.
3-4 Option Code
Table of option codes for various indoor unit types and models.
Disassembly and Reassembly
4-1 Outdoor Unit Disassembly and Reassembly
Procedures for disassembling and reassembling outdoor units, including necessary tools.
Exploded Views and Parts List
5-1 Indoor Unit Exploded Views and Parts
Exploded views and parts lists for 1-way cassette type indoor units.
5-2 Outdoor Unit Exploded Views and Parts
Exploded views and parts lists for 4/5/6HP mini DVM outdoor units.
5-3 Outdoor Unit Exploded Views and Parts
Exploded views and parts lists for 8/10HP DVM Plus2/DVM HR2 outdoor units.
Wiring Diagram
6-1 Indoor Unit Wiring Diagrams
Wiring diagrams for various indoor unit types, including connections and components.
6-2 Outdoor Unit Wiring Diagrams
Wiring diagrams for various outdoor unit types, including phase and component connections.
Schematic Diagram
7-1 Indoor Unit Schematic Diagrams
Schematic diagrams for various indoor unit PCBs, showing component connections.
7-2 Outdoor Unit Schematic Diagram (mini DVM Series)
Schematic diagram for the mini DVM Series outdoor unit PCB.
7-3 Outdoor Unit Schematic Diagrams (DVM Plus2/DVM HR2 Series)
Schematic diagrams for DVM Plus2/HR2 Series outdoor unit PCBs.
PCB Diagram
8-1 Indoor Unit PCB Diagrams
PCB diagrams for 1-way cassette type indoor units, showing connector and switch functions.
8-1-2 2 way cassette type PCB Diagram
PCB diagram for 2-way cassette type indoor units, showing connector functions.
8-1-3 4 way cassette type PCB Diagram
PCB diagram for 4-way cassette type indoor units, showing connector functions.
8-1-5 Duct type(Low silhouette/Built-in) PCB Diagram
PCB diagram for low silhouette/built-in duct type indoor units, showing connector functions.
Troubleshooting
9-1 Outdoor Unit Operating Flow
Flowchart for outdoor unit operation and error detection.
9-2 Indoor Unit LED Self Diagnosis
Indoor unit LED error codes and their meanings for various operation modes.
9-3 DVM Plus2 Series Fault Diagnosis
Fault diagnosis and causes for DVM Plus2 Series errors related to outdoor temperature.
9-4 mini DVM Series Fault Diagnosis
Fault diagnosis and causes for mini DVM Series errors related to indoor unit sensors.
9-5 DVM HR2 Series Fault Diagnosis
Fault diagnosis and causes for DVM HR2 Series errors related to communication and MCU setup.
Reference Information
10-1 Model Name Index
Explains the model code structure for indoor and outdoor units.
10-2 mini DVM Series Special Operation Modes
Details on setting option switches for mini DVM Series outdoor units.
10-3 DVM Plus2 Series Special Operation Modes
Procedures for special operation modes like Refrigerant Collection and Pump Down.
10-4 R410A Refrigerant Information
Characteristics, design pressure, toxicity, and ODP of R410A refrigerant.
10-5 Additional Refrigerant Calculation
Method for calculating additional refrigerant charge based on pipe length and diameter.
10-6 Exclusive Tools for R410A
Lists exclusive tools and their usage for R410A refrigerant work.
10-7 Q & A for Non-trouble
Frequently asked questions and troubleshooting for non-trouble scenarios like weak cooling or leaks.
10-8 Refrigerant Circuit Diagram
Refrigerant circuit diagrams for cooling and heating operations.

Table of Contents