Summary of Contents for TP-Link Omada Pro S6500-24G4XF
Page 1
Business Networking Solution Installation Guide Omada Pro Stackable L3 Managed Switch...
Page 3
Remind to take notice. The note contains the helpful information for a better use of the product. Related Document The User Guide and CLI Reference Guide of the product are provided on Download Center. To obtain the latest product information, visit the official website: https://www.tp-link.com.
Omada Pro Stackable L3 Managed Switch Chapter 1 Introduction Product Overview Designed for enterprise and campus, Omada Pro Stackable L3 Managed Switch provides wire-speed performance and abundant L2 and L3 management features. It provides a variety of service features and multiple powerful functions with high security.
Page 6
Omada Pro Stackable L3 Managed Switch The front panel of S6500-24GP4XF is shown as the following figure. Mode Selection Button Management Port Console Port 10G SFP+ Slot LED USB2.0 Port 1G RJ45 Port (Type-C/RJ45) The front panel of S6500-48GP6XF is shown as the following figure. Mode Selection Button Management...
Page 7
Omada Pro Stackable L3 Managed Switch The front panel of S7500-26XF6Y is shown as the following figure. Management Port Console Port 25G SFP28 Slot 10G SFP+ Slot USB3.0 Port (RJ45/Type-C) (Port 27-32) (Port 1-26) Mode Selection Button The front panel of S7500-24Y4C is shown as the following figure. Management Port Console Port...
Page 8
Omada Pro Stackable L3 Managed Switch LEDs For S6500-24G4XF and S6500-48G6XF PWR1* PWR2 Indication The switch is powered by PWR1. Green On PWR2 is disconnected or it works improperly. The switch is powered by PWR1. Green On Yellow On** PWR1 and PWR2 are connected.* The switch is powered by PWR2.
Page 9
Omada Pro Stackable L3 Managed Switch S6500-24GP4XF, S6500-48GP6XF, S6500-24MPP4Y and S6500-48MPP6Y Indication Green On: The power supply works properly. Green Flashing: The power supply module is not plugged in properly or not compatible with the switch. PWR1* Yellow On: The power supply works properly but the switch is powered by the other power supply.** PWR2 Yellow Flashing: The power supply module is plugged in properly but...
Page 10
Omada Pro Stackable L3 Managed Switch Indication Green On: Running at 10 Gbps, but no activity. Green Flashing: Running at 10 Gbps and transmitting or receiving data. Port 25-28 of S6500- 24GP4XF/Port 49-54 of Yellow On: Running at 1 Gbps, but no activity. S6500-48GP6XF*** Yellow Flashing: Running at 1 Gbps and transmitting or receiving data.
Page 11
Omada Pro Stackable L3 Managed Switch Indication Green On: Running at 25 Gbps, but no activity. Green Flashing: Running at 25 Gbps and transmitting or receiving data. Port 1-24 of S7500-24Y4C Yellow On: Running at 1 Gbps/10 Gbps, but no activity. Yellow Flashing: Running at 1 Gbps/10 Gbps and transmitting or (When the SPD LED is on) receiving data.
Page 12
Omada Pro Stackable L3 Managed Switch 25G SFP28 Slot Designed to install the 25 Gbps/10 Gbps/1 Gbps optical module. 100G QSFP28 Slot Designed to install the 100 Gbps/40 Gbps optical module. Port Feature 1000M 2.5G 10G SFP+ 25G SFP28 100G QSFP28 Management Console Model...
PE (Protecting Earth) cable of AC cord or with Ground Cable. For detailed lightning protection measures, refer to the Lightning Protection Guide from the Related Documents: https://www.tp-link.com/us/configuration-guides/lightning_protection_guide/. Power Socket Connect the female connector of the power cord here, and the male connector to the AC power outlet.
Omada Pro Stackable L3 Managed Switch Chapter 2 Installation Package Contents Make sure that the package contains the following items. Please contact your distributor, if any of the listed items is damaged or missing. The figures are for demonstration only. The actual items may differ in appearance and quantity from the depicted.
Page 15
Omada Pro Stackable L3 Managed Switch Temperature/Humidity Keep the equipment room at an appropriate level of temperature and humidity. Too much or too little humidity may lead to bad insulation, leakage of electricity, mechanical property changes, and corrosion. High temperatures may accelerate aging of the insulation materials, significantly shortening the service life of the device.
■ Note: For detailed lightning protection measures, refer to the Lightning Protection Guide from the Related Documents: https://www.tp-link.com/us/configuration-guides/lightning_protection_guide/. Installation Site When installing the device on a rack or a flat workbench, attach much importance to the following items: Install the device with its bottom surface facing down only.
Omada Pro Stackable L3 Managed Switch Phillips screwdriver ■ ESD-preventive wrist wrap ■ Cables ■ Note: These tools are not included with our product. If needed, you can purchase them separately. Product Installation The switch is designed with front-to-back heat dissipation feature. When it works, the air circulates as shown below.
Page 18
Omada Pro Stackable L3 Managed Switch Figure 2-3 Mounting Brackets Screw Hole Group 2 Bracket A Screw Hole Group 1 Bracket B Screw Hole Group 3 Bracket C Bracket D Before installing the device in an EIA standard-sized, 19-inch rack, please check the efficiency of the grounding system and the stability of the rack, then wear an ESD-preventive wrist strap, and make sure that it has good skin contact and is well grounded.
Page 19
Omada Pro Stackable L3 Managed Switch Front: Bracket D Rear: 357-410mm 397-450mm 437-490mm Bracket A (Screw Hole Group 3) + Bracket C (Ear towards back) Front: Bracket D Rear: 282-410mm 322-450mm 362-490mm Bracket A (Screw Hole Group 2) + Bracket B (Ear towards back) To install the device, follow the instructions described below: 1.
Page 20
Omada Pro Stackable L3 Managed Switch Figure 2-6 Installing Brackets on Switch 4. After the brackets are attached to the device, hold the switch with attached brackets up until it aligns with the brackets on the racks, and gently push the switch backwards until it is in place, then secure the device on the racks with M6 screws and fix brackets B/C to brackets A with M4 screws on both sides.
Omada Pro Stackable L3 Managed Switch Power Supply Module Installation ■ S6500-24GP4XF is shipped with a PSM500-AC power supply module installed, S6500-48GP6XF/ S6500-24MPP4Y/S6500-48MPP6Y is shipped with a PSM900-AC power supply module installed, and S7500-26XF6Y/S7500-24Y4C is shipped with a PSM550-AC power supply module installed. They look like below, and the images may differ from your actual product.
Omada Pro Stackable L3 Managed Switch 3. Press the extraction handle of the module with one hand, and pull the extraction handle using your other hand, until the module completely comes out of the chassis. Caution: Unplug the power cord first, then remove the power supply module. ■...
Page 23
Omada Pro Stackable L3 Managed Switch 4. Release the extraction handle to fix the power supply module in place. Caution: Sharp edges on the fan module may cause injury, so please operate with caution. ■ Make sure the damaged fan module is in place before you are going to replace it. DO NOT ■...
Omada Pro Stackable L3 Managed Switch Chapter 3 Connection Ethernet Port Connect an Ethernet port of the switch to the computer by RJ45 cable as the following figure shows. Figure 3-1 Connecting the RJ45 Port RJ45 Port RJ45 Cable 10G SFP+/25G SFP28/100G QSFP28 Slot The following figure demonstrates the connection of 10G SFP+/25G SFP28/100G QSFP28 slot to an optical module.
Omada Pro Stackable L3 Managed Switch Figure 3-3 Connecting the Console (RJ45) Port Connect the Type-C console port of the device with your computer by the Type-C cable (not provided) as the following figure shows. Figure 3-4 Connecting the Console (USB) Port Note: RJ45 console port and Type-C console port cannot be used concurrently.
Omada Pro Stackable L3 Managed Switch Power On Plug the female connector of the provided power cord into the power socket of the device and plug the positive connector into a power outlet as the following figure shows. Make sure that the voltage of the power supply meets the requirement of the input voltage (100-240 V~ 50/60 Hz).
Page 27
Omada Pro Stackable L3 Managed Switch 2-12 (max 12 in standalone mode, S6500-24MPP4Y S6500-24MPP4Y, S6500-48MPP6Y max 4 in controller mode) 2-12 (max 12 in standalone mode, S6500-48MPP6Y S6500-24MPP4Y, S6500-48MPP6Y max 4 in controller mode) 2-12 (max 12 in standalone mode, S7500-26XF6Y S7500-26XF6Y max 4 in controller mode)
Page 28
Omada Pro Stackable L3 Managed Switch Figure 3-8 Star Topology Stacking Port Group 2 Stacking Port Group 3 Stacking Port Group 1 Note: • Stacking port is not allowed to connect to non-stacking port, as it may affect the operation of the device.
3. After a successful login, the main page will appear. You can click the menus on the top side and left side to configure the corresponding functions. For the detailed configurations, refer to the User Guide and CLI Guide. The guides can be found on the download center of our official website: https://www.tp-link.com/support/download/?type=smb. Using the CLI ■...
None For the detailed configurations, refer to the User Guide and CLI Guide. The guides can be found on the download center of our official website: https://www.tp-link.com/support/download/?type=smb Note: For certain devices, you may need to change the password the first time you log in, which will better protect your network and devices.
Page 31
Launch a web browser and enter https://omada.tplinkcloud.com in the address bar. Enter your TP-Link ID and password to log in. Click + Add Controller and choose Hardware Controller to add your controller. Then you can further configure the controller.
Page 32
2) Launch a web browser and enter https://omada.tplinkcloud.com in the address bar. Log in with your TP-Link ID. A list of controllers that have been bound with your TP-Link ID will appear. Then you can launch the controller to adopt and manage devices.
Page 33
With the Omada app, you can also manage your controller at a local site or a remote site via your mobile device. For the detailed configurations, refer to the User Guide of the controller. The guide can be found on the download center of our of ficial website: https://w w w.tp-link.com/support / download/?type=smb. Configuration...
Appendix A Troubleshooting Q1. What could I do if I forgot the username and password of the switch? Connect the console port of the PC to the console port of the switch and open a terminal emulation program. Power off and restart the switch. Perform the action indicated by the terminal emulation program to reach the bootUtil menu.
Appendix B Specifications Specifications for Switches with RJ45 Ports and 10G SFP+/25G SFP28 Slots Item Content IEEE 802.3, IEEE 802.3i, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3z, IEEE 802.3ae, IEEE 802.3x Standards IEEE 802.3af/at (For S6500-24GP4XF, S6500-48GP6XF) IEEE 802.3af/at /bt, IEEE 802.3by, IEEE 802.3cc (For S6500-24MPP4Y, S6500-48MPP6Y) 10BASE-T: 2-pair UTP/STP of Cat. 3,4,5 (maximum 100 m) 100BASE-TX: 2-pair UTP/STP of Cat.
Page 36
For S6500-24GP4XF: 402W (with 1*PSM500-AC, by default) 720W (with 1*PSM900-AC) 720W (with 2*PSM500-AC) 720W (with 2*PSM900-AC) 720W (with 1*PSM500-AC and 1*PSM900-AC) For S6500-48GP6XF 384W (with 1*PSM500-AC) 764W (with 1*PSM900-AC, by default) 812W (with 2*PSM500-AC) 1440W (with 2*PSM900-AC) 1176W (with 1*PSM500-AC and 1*PSM900-AC) PoE Budget For S6500-24MPP4Y: 378W (with 1*PSM500-AC)
Page 37
Operating Humidity 10% to 90% RH Non-condensing Storage Humidity 5% to 90% RH Non-condensing △ The supported altitude is sea level to 3000 m. It should be noted that when the altitude is above 2000 m, for every 220 meters of altitude increase, the maximum operating temperature will drop by 1°C (1.8°F). Specifications for Switches with Full 10G SFP+/25G SFP28/100G QSFP28 Slots (S7500-26XF6Y, S7500-24Y4C) Item...
Page 38
Specifications for Power Supply Modules PSM500-AC PSM900-AC PSM550-AC (For S6500-24GP4XF (For S6500-24GP4XF & S6500-48GP6XF & S6500-48GP6XF (For S7500-26XF6Y & & S6500-24MPP4Y & & S6500-24MPP4Y & S7500-24Y4C) S6500-48MPP6Y) S6500-48MPP6Y) 100-120V (included)~ 50/60Hz 12A (for locations using low voltage, see 100 V–240 V~ 50/60 Hz specifications for 100 V–240 V~ 50/60 Hz Power Input...
EU Declaration of Conformity TP-Link hereby declares that the device is in compliance with the essential requirements and other relevant provisions of directives 2014/30/EU, 2014/35/EU, 2011/65/EU and (EU)2015/863. The original EU Declaration of Conformity may be found at https://www.tp-link.com/en/support/ce/...
Page 40
Please use this product with care and operate at your own risk. To ask questions, find answers, and communicate with TP-Link users or engineers, please visit https://community.tp-link.com/business to join TP-Link Community.
This manual is also suitable for:
Omada pro s6500-24gp4xfOmada pro s6500-48g6xfOmada pro s6500-48gp6xfOmada pro s6500-24mpp4yOmada pro s6500-48mpp6yOmada pro s7500-26xf6y...
Show all
Need help?
Do you have a question about the Omada Pro S6500-24G4XF and is the answer not in the manual?
Questions and answers