Page 1
To those who i nsta I I the unit Method of REMOVE the Transportation fitting plate(s) �CAUTION Check a l I outside the unit. If there is the Transportation fitting plate(s), Loosen screws with a suitable tool. 3 Take off the Transportation fitting plate(s) carefully. DO NOT OPERATE THIS OUTDOOR UNIT 4 After removing t h e Transportat i on fit t i ng pl a t e (s).
PROTECT THE ENVIORNMENT FROM E-WASTE (GUIDELINES) Meaning of E-waste under E-waste (Management) Rules, 2022 (E-waste rules) - Waste, electrical and electronic equipment, whole or in part of reject from their manufacturing and repair process, which are intended to be discarded. Our product is RoHS compliant.
Page 4
Thank you for purchasing this Daikin air conditioner. Carefully read this operation manual before using the air conditioner. It will tell you how to use the unit properly and help you if any trouble occurs. After reading the manual, keep it in your custody for future reference.
Operation manual 1. Definitions Contents 1.1. Meaning of warnings and symbols Page 1. Definitions ..........Warnings in this manual are classified according 1.1. Meaning of warnings and symbols ..to their severity and probability of occurrence. 1.2. Meaning of used terms ......1.3.
Equipment which needs to be installed according with electrical parts. to instructions in this manual, but which are not supplied by Daikin. • Consult your local dealer about installation work. Doing the work yourself may result in water leakage, electric shocks or fire hazards.
Page 7
• Consult your local dealer regarding what to • Be sure to install an earth leakage breaker. Failure to install an earth leakage breaker may do in case of refrigerant leakage. result in electric shocks or fire. When the air conditioner is to be installed in a In order to avoid electric shock or fire, make small room, it is necessary to take proper sure that an earth leak detector is installed.
Page 8
• Be sure to use a dedicated power supply for • Do not place burners or heaters in places the air conditioner. exposed to the air flow from the unit as this The use of any other power supply may cause may impair combustion of the burner or heat generation, fire or product failures.
Page 9
• To avoid injury, do not touch the air inlet or • Do not use the air conditioner for purposes aluminium fins of the unit. other than those for which it is intended. These fins are sharp and could result in cutting Do not use the air conditioner for cooling injuries.
Consult your installer. • Names and functions of parts (Refer to figure 1) 1. Outdoor unit System relocation 2. Indoor unit • Consult your Daikin about remodelling and 3. Remote controller 4. Air inlet relocation. 5. Air outlet...
3. Before operation 6. Operation procedure This operation manual is for the following systems • Operation procedure varies according to the with standard control. Before initiating operation, combination of outdoor unit and user interface. contact your dealer for the operation that corresponds Read the chapter 3 "Before operation"...
ADJUSTMENT Defrost operation For adjustment the desired temperature, fan • In heating operation, freezing of the outdoor unit's speed and air flow direction (only for the air cooled coil increases over time, restricting the remote controller, follow the procedure shown energy transfer to the outdoor unit's coil.
6.3 Adjusting the air flow direction 6.2 Program dry operation • The function of this program is to decrease the humidity in your room with minimal ,,DAIKIN temperature decrease (minimal room cooling). • The microcomputer automatically determines temperature and fan speed (cannot be set by the user interface).
The air flow flap itself adjusts its position. • The air flow direction can be fixed by the user. c:::!:S Automatic or desired position ,,.DAIKIN (ff} NOTICE • The movable limit of the flap is changeable. Contact your dealer for details. (only for double-flow, multiflow, corner, ceiling-suspended and wall-mounted).
• Do not use other heating devices directly INFORMATION beneath the indoor unit. For another user interfaces refer to the Othetwise , the unit might be get deformed by operation manual of the operation procedured the heat. user interface. • Condensation may form if the humidity is 7.
• Immediately after the power is turned on. The 8.2 Maintenance before a long stop period (e.g., at the end of the season) microcomputer is getting ready to operate and is performing a communication check with all indoor • Let the indoor units run in fan only operation units.
• This is to prevent oil and refrigerant from 9.8 Noise of air conditioners remaining in the compressor. The unit will 1.) Indoor unit stop after 5 to 1 O minutes. • A "zeen" sound is heard immediately after the 9.14 The inside of an outdoor unit is warm power supply is turned on.
If the system does not properly operate except • Check if the air flow angle is proper. for the above mentioned cases and none of the If the checking all above items, it is impossible to above mentioned malfunctions is evident, fix the problem your self, contact your installer and investigate the system according to the state the symptoms, the complete model name of...
• Do not remove or reinstall the unit by yourself. • Bumps and vibrations are frequent. • Incorrect installation may cause electrical Dust, salt, harmful gas or oil mist such as shock or fire. sulphurous acid and hydrogen sulfide may be Contact your dealer.
11.4 Malfunction codes Contents In case a malfunction code appears on the indoor unit user interface display, contact your installer Refrigerant overcharge detection and inform the malfunction code, the unit type High pressure switch malfunction and serial number (you can find this information H'-1 Low pressure switch malfunction on the nameplate of the unit).
Page 21
DAIKIN AIRCONDITIONING INDIA PVT. LTD. Head office: 12th Floor, Building No.9,Tower A, DLF Cyber City, DLF Phase-Ill, Gurgaon-122 002, Haryana, India www.daikinindia.com 3P785207-1A...
(C) Where there are obstacles on both suction and 2P565691-1 discharge sides: Where the obstacles on the discharge side is higher than the unit: Installation Manual (2) Pattern 1 (There is no height limit for obstructions on the intake side.) •...
Page 23
Perform wiring connection in accordance with "Electrical Wiring Diagram Label�. • If it is necessary to hang it on the wall, be sure to ask Daikin dealer to perform installa B ! �ure tp !nJtall �he d �...
Page 24
<Manual refrigerant charging> Note • After starting field setting [2-20]=1 , the unit will start manual refrigerant charging. • The refrigerant will be charged about 22kg in one hour at outdoor temperature of 3o•c DB (About 6kg at o·c DB) Refrigerant piping connection) •...
Need help?
Do you have a question about the VRV RXMQ10BRY1 and is the answer not in the manual?
Questions and answers