7368 ISAM ONT G-120W-F Product Guide
R05.06.01 | June 2017 | Edition 01
7368 Intelligent Services Access
Manager ONT
7368 ISAM ONT G-120W-F Product Guide
3FE-46922-AAAA-TCZZA
Issue: 01
Nokia — Proprietary and confidential
Use pursuant to applicable agreements

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 7368 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Nokia 7368

  • Page 1 7368 ISAM ONT G-120W-F Product Guide R05.06.01 | June 2017 | Edition 01 7368 Intelligent Services Access Manager ONT 7368 ISAM ONT G-120W-F Product Guide 3FE-46922-AAAA-TCZZA Issue: 01 Nokia — Proprietary and confidential Use pursuant to applicable agreements...
  • Page 2 © 2017 Nokia. Contains proprietary/trade secret information which is the property of Nokia and must not be made available to, or copied or used by anyone outside Nokia without its written authorization. Not to be used or disclosed except in accordance with applicable agreements.
  • Page 3: Preface

    The expansions and optional descriptions of most acronyms and initialisms appear in the glossary. 1.5 Assistance and ordering phone numbers Nokia provides global technical support through regional call centers. Phone numbers for the regional call centers are available at the following URL: http://support.alcatel-lucent.com.
  • Page 4: Nokia Quality Processes

    To download a ZIP file package of the customer documentation Navigate to http://support.alcatel-lucent.com and enter your user name and password. If you are a new user and require access to this service, please contact your Nokia sales representative. From the Technical Content for drop-down menu, choose the product.
  • Page 5: Special Information

    Individual PDFs of customer documents are also accessible through the Nokia Customer Support website. Navigate to http://support.alcatel-lucent.com and enter your user name and password. If you are a new user and require access to this service, please contact your Nokia sales representative. From the Technical Content for drop-down menu, choose the product.
  • Page 6: Procedures With Options Or Substeps

    R05.06.01 | June 2017 | Edition 01 Preface 7368 ISAM ONT G-120W-F Product Guide 1.9.1 Procedures with options or substeps When there are options in a procedure, they are identified by letters. When there are required substeps in a procedure, they are identified by roman numerals.
  • Page 7: Multiple Pdf Document Search

    R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide Preface 1.10 Multiple PDF document search You can use Adobe Reader Release 6.0 and later to search multiple PDF files for a common term. Adobe Reader displays the results in a single display panel. The results are grouped by PDF file, and you can expand the entry for each file.
  • Page 8 R05.06.01 | June 2017 | Edition 01 Preface 7368 ISAM ONT G-120W-F Product Guide 3FE-46922-AAAA-TCZZA Issue: 01...
  • Page 9: Table Of Contents

    R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide Table of contents Preface.....................3 Scope ......................3 Audience......................3 Required knowledge..................3 Acronyms and initialisms ................3 Assistance and ordering phone numbers ............3 Nokia quality processes................4 Safety information..................4 Documents ....................4 Special information ..................5 1.9.1...
  • Page 10 R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide 3.3.1 ONT environmental requirements .............30 3.3.2 Storage ......................30 3.3.3 Transportation ...................30 3.3.4 Stationary use....................30 3.3.5 Thermal limitations ..................30 3.3.6 Material content compliance..............31 3.3.7 End-of-life collection and treatment ............31 ANSI ONT safety guidelines ............33...
  • Page 11 R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide 5.10 G-120W-F standards compliance..............61 5.10.1 Energy-related products standby and off modes compliance....62 5.11 G-120W-F special considerations .............62 5.11.1 Wi-Fi service....................62 5.11.1.1 Wi-Fi physical features ................63 5.11.1.2 Wi-Fi standards and certifications .............63 5.11.1.3...
  • Page 12 R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide 3FE-46922-AAAA-TCZZA Issue: 01...
  • Page 13: List Of Figures

    R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide List of figures ETSI ONT safety guidelines ............17 Figure 1 PSE certification ..................19 Figure 2 Laser product label ..................22 Figure 3 Laser classification label................23 Figure 4 Laser warning labels..................24 ETSI environmental and CRoHS guidelines.......27...
  • Page 14 R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide Figure 35 WAN network window................96 Figure 36 WAN DHCP window ..................97 Figure 37 Wireless 2.4GHz network window .............99 Figure 38 Wireless Schedule window..............101 Figure 39 IP Routing network window ..............102 Figure 40 DNS network window ................104...
  • Page 15: List Of Tables

    R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide List of tables ETSI ONT safety guidelines ............17 Table 1 Safety labels ....................18 ANSI ONT safety guidelines ............33 Table 2 Safety labels ....................34 G-120W-F unit data sheet.............45 Table 3 Identification of G-120W-F indoor ONTs ...........46...
  • Page 16 R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide Table 38 Access control parameters ..............116 Table 39 Port forwarding parameters ..............118 Table 40 Port triggering parameters...............119 Table 41 DDNS parameters ...................121 Table 42 Voice setting parameters.................124 Table 43 Password parameters................125...
  • Page 17: Etsi Ont Safety Guidelines

    R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide ETSI ONT safety guidelines 2 ETSI ONT safety guidelines This chapter provides information about the mandatory regulations that govern the installation and operation of the optical network terminals (ONTs).
  • Page 18: Etsi Ont Safety Guidelines

    R05.06.01 | June 2017 | Edition 01 ETSI ONT safety guidelines 7368 ISAM ONT G-120W-F Product Guide The following is an example of the Caution box. Possibility of service interruption. Caution 1 — Service interruption. Caution 2 — The Caution box indicates that the described activity or situation may, or will, cause service interruption.
  • Page 19: Safety Standards Compliance

    R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide ETSI ONT safety guidelines Figure 1 PSE certification This is a Class B product based on the standard of the Voluntary Control Council for Interference from Information Technology Equipment (VCCI). If this is used near a radio or television receiver in a domestic environment, it may cause radio interference.
  • Page 20: Environmental Standard Compliance

    R05.06.01 | June 2017 | Edition 01 ETSI ONT safety guidelines 7368 ISAM ONT G-120W-F Product Guide 2.2.3 Environmental standard compliance The ONT equipment complies with the EN 300 019 European environmental standards. 2.2.4 Laser product standard compliance For most ONTs, the ONT equipment complies with EN 60825-1 and IEC 60825-2 for laser products.
  • Page 21: Power Supplies

    The use of any non-Nokia approved power supplies or power adapters is not supported or endorsed by Nokia. Such use will void any warranty or support contract with Nokia. Such use greatly increases the danger of damage to equipment or property.
  • Page 22: Laser Classification

    R05.06.01 | June 2017 | Edition 01 ETSI ONT safety guidelines 7368 ISAM ONT G-120W-F Product Guide Only qualified service personnel who are extremely familiar with laser radiation hazards should install or remove the fiber optic cables and units in this system.
  • Page 23: Figure 3 Laser Classification Label

    R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide ETSI ONT safety guidelines Figure 3 Laser classification label CLASS 1 LASER PRODUCT PRODUCTO LASER CLASE 1 CLASE 1 DEL LASER LASER CLASSE 1 18992 Figure shows a laser warning label and an explanatory label for laser products.
  • Page 24: Transmit Optical Output

    R05.06.01 | June 2017 | Edition 01 ETSI ONT safety guidelines 7368 ISAM ONT G-120W-F Product Guide Figure 4 Laser warning labels INVISIBLE LASER RADIATION DO NOT STARE INTO BEAM OR VIEW DIRECTLY WITH OPTICAL INSTRUMENTS Wavelength(s): xxxx nm Normal output power: xx m W...
  • Page 25: Location Class

    R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide ETSI ONT safety guidelines 2.5.4 Location class Use cable supports and guides to protect the receptacles from strain. 2.6 Environmental requirements See the ONT technical specification documentation for more information about temperature ranges.
  • Page 26 R05.06.01 | June 2017 | Edition 01 ETSI ONT safety guidelines 7368 ISAM ONT G-120W-F Product Guide 3FE-46922-AAAA-TCZZA Issue: 01...
  • Page 27: Etsi Environmental And Crohs Guidelines

    R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide ETSI environmental and CRoHS guidelines 3 ETSI environmental and CRoHS guidelines This chapter provides information about the ETSI environmental China Restriction of Hazardous Substances (CRoHS) regulations that govern the installation and operation of the optical line termination (OLT) and optical network termination (ONT) systems.
  • Page 28: Products Containing Hazardous Substances Above Maximum Concentration Value (Mcv) Label

    R05.06.01 | June 2017 | Edition 01 ETSI environmental and CRoHS guidelines 7368 ISAM ONT G-120W-F Product Guide Figure 5 Products below MCV value label 18986 3.1.2.2 Products containing hazardous substances above Maximum Concentration Value (MCV) label Figure shows the label that indicates a product is above the maximum...
  • Page 29: Hazardous Substances Table (Hst)

    OLT and ONT documentation. In accordance with the People’s Republic of China Electronic Industry Standard Marking for the Control of Pollution Caused by Electronic Information Products (SJ/T11364-2006), customers may access the Nokia Hazardous Substance Table, in Chinese, from the following location: •...
  • Page 30: Other Environmental Requirements

    R05.06.01 | June 2017 | Edition 01 ETSI environmental and CRoHS guidelines 7368 ISAM ONT G-120W-F Product Guide 3.3 Other environmental requirements Observe the following environmental requirements when handling the P-OLT or ONT equipment. 3.3.1 ONT environmental requirements See the ONT technical specification documentation for more information about temperature ranges.
  • Page 31: Material Content Compliance

    This Directive applies to electrical and electronic products placed on the EU market after 1 July 2006, with various exemptions, including an exemption for lead solder in network infrastructure equipment. Nokia products shipped to the EU after 1 July 2006 comply with the EU RoHS Directive.
  • Page 32 European Union. In compliance with legal requirements and contractual agreements, where applicable, Nokia will offer to provide for the collection and treatment of Nokia products bearing the logo shown in Figure at the end of their useful life, or products displaced by Nokia equipment offers.
  • Page 33: Ansi Ont Safety Guidelines

    R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide ANSI ONT safety guidelines 4 ANSI ONT safety guidelines This chapter provides information about the mandatory regulations that govern the installation and operation of the optical network terminals or units (ONTs or ONUs) in the North American or ANSI market.
  • Page 34: Safety-Related Labels

    R05.06.01 | June 2017 | Edition 01 ANSI ONT safety guidelines 7368 ISAM ONT G-120W-F Product Guide The following is an example of the Caution box. Possibility of service interruption. Caution 1 — Service interruption. Caution 2 — The Caution box indicates that the described activity or situation may, or will, cause service interruption.
  • Page 35: Safety Standards Compliance

    R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide ANSI ONT safety guidelines Description Label text Operation conditions This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 36: Emc, Emi, And Esd Standards Compliance

    R05.06.01 | June 2017 | Edition 01 ANSI ONT safety guidelines 7368 ISAM ONT G-120W-F Product Guide 4.2.1 EMC, EMI, and ESD standards compliance The ONT equipment complies with the following requirements: • Federal Communications Commission (FCC) CFR 47, Part 15, Subpart B, Class A requirements for OLT equipment •...
  • Page 37: Environmental Standards Compliance

    Per CDRH 21 CFR 10.40.10 (h) (1) (iv) distributors of Class 1 laser products, such as Nokia ONTs shall leave the following Laser Safety cautions with the end user. a) “Class 1 Laser Product” b) “Caution – Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure.”...
  • Page 38: Resistibility Requirements Compliance

    Per CDRH 21 CFR 10.40.10 (h) (1) (iv) distributors of Class 1 laser products, such as Nokia ONTs shall leave the following Laser Safety cautions with the end user. a) “Class 1 Laser Product” b) “Caution – Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure.”...
  • Page 39: Figure 10 Laser Product Label

    R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide ANSI ONT safety guidelines Figure 10 Laser product label 18455 Figure shows a laser classification label. Laser classification labels may be provided in other languages. Figure 11...
  • Page 40: Laser Classification

    R05.06.01 | June 2017 | Edition 01 ANSI ONT safety guidelines 7368 ISAM ONT G-120W-F Product Guide Figure 12 Laser warning labels INVISIBLE LASER RADIATION DO NOT STARE INTO BEAM OR VIEW DIRECTLY WITH OPTICAL INSTRUMENTS Wavelength(s): xxxx nm Normal output power: xx m W...
  • Page 41: Transmit Optical Output

    R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide ANSI ONT safety guidelines Figure 13 Sample laser product safety label on the ONT equipment Model: 3FE55851ABAA MFG: MONTH: XX YEAR: XXXX MAC:XXXXXXXXXXXX ICS: XX MRev: XX SN:ALCLXXXXXXXX I.T.E...
  • Page 42: Electrical Safety Guidelines

    The use of any non-Nokia approved power supplies or power adapters is not supported or endorsed by Nokia. Such use will void any warranty or support contract with Nokia. Such use greatly increases the danger of damage to equipment or property.
  • Page 43: Environmental Requirements

    During installation and maintenance, service personnel must wear wrist straps to prevent damage caused by ESD. Nokia recommends that you prepare the site before you install the ONT equipment. In addition, you must control relative humidity, use static dissipating material for furniture or flooring, and restrict the use of air conditioning.
  • Page 44 R05.06.01 | June 2017 | Edition 01 ANSI ONT safety guidelines 7368 ISAM ONT G-120W-F Product Guide 3FE-46922-AAAA-TCZZA Issue: 01...
  • Page 45: 120W-F Unit Data Sheet

    R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide G-120W-F unit data sheet 5 G-120W-F unit data sheet 5.1 G-120W-F part numbers and identification 5.2 G-120W-F general description 5.3 G-120W-F software and installation feature support 5.4 G-120W-F interfaces and interface capacity 5.5 G-120W-F LEDs...
  • Page 46: G-120W-F Part Numbers And Identification

    R05.06.01 | June 2017 | Edition 01 G-120W-F unit data sheet 7368 ISAM ONT G-120W-F Product Guide 5.1 G-120W-F part numbers and identification Table provides part numbers and identification information for the G-120W-F indoor ONT. Table 3 Identification of G-120W-F indoor ONTs...
  • Page 47: G-120W-F General Description

    R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide G-120W-F unit data sheet For the G-120W-F indoor ONT power supply information, contact your Nokia technical support representative. 5.2 G-120W-F general description G-120W-F indoor ONTs provide the subscriber interface for the network by terminating the PON interface and converting it to user interfaces that directly connect to subscriber devices.
  • Page 48: Support

    R05.06.01 | June 2017 | Edition 01 G-120W-F unit data sheet 7368 ISAM ONT G-120W-F Product Guide 5.2.1 TR-069 support The ONT supports the reading of optical parameters via TR-069: • laser bias current • voltage • temperature • received signal levels •...
  • Page 49: Mobile Offload Support

    R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide G-120W-F unit data sheet The following TR-181 Wi-Fi objects (and sub-objects) adapted in TR-098 are supported in this release: • Device.WiFi • Device.WiFi.Radio.{i}. • Device.WiFi.Radio.{i}.Stats. • Device.WiFi.SSID.{i}.
  • Page 50: Bridged Residential Gateway (Brg) Support

    This section describes the support for soft GRE tunnels for integration with the 7750 Service Router WLAN gateway. The Nokia 7750 Service Router WLAN GW can accept soft GRE tunnels from any IP Source Address, in a preconfigured Subnet or Access Control List, or MPLS label.
  • Page 51: Soft Gre

    IPTV Network 25265 For more information about soft GRE architecture and configuration procedures, see the 7368 Configuration, Management, and Troubleshooting guide, which contains the vCPE User Guide. While the vCPE forwards all traffic over the GRE Note — tunnel, the soft GRE architecture for the G-120W-F enables the operator to restrict the traffic over the GRE tunnel bases on SSIDs or LAN ports.
  • Page 52: G-120W-F Software And Installation Feature Support

    For information on installing or replacing the G-120W-F see: • Install a G-120W-F indoor ONT • Replace a G-120W-F indoor ONT For information on the following topics, see the 7368 ISAM ONT Product Overview Guide: • ONT and MDU general descriptions of features and functions •...
  • Page 53: Figure 15 G-120W-F Indoor Ont Physical Connections

    R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide G-120W-F unit data sheet Figure 15 G-120W-F indoor ONT physical connections Antenna Antenna GPON LAN2 LAN1 POWER RESET WLAN ON/OFF Fiber POTS Ethernet Power Reset Wireless LEDs...
  • Page 54: G-120W-F Leds

    R05.06.01 | June 2017 | Edition 01 G-120W-F unit data sheet 7368 ISAM ONT G-120W-F Product Guide 5.5 G-120W-F LEDs Figure shows the G-120W-F indoor ONT LEDs. Figure 16 G-120W-F indoor ONT LEDs POWER LINK AUTH LAN1 LAN2 VOIP WLAN INTERNET...
  • Page 55: G-120W-F Detailed Specifications

    R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide G-120W-F unit data sheet Indicator LED color and LED behavior description behavior Green solid WiFi protected setup link is up (negotiation and auto-configuration successful) Green flashing WiFi protected setup link activity (negotiation and auto-configuration ongoing)
  • Page 56: G-120W-F Gem Ports And T-Conts

    PONONTTC aggregate type counters If you have trouble accessing G-120W-F ONTs Note — performance monitoring statistics using TL1, please contact your Nokia support representative for more information about how to access and retrieve performance monitoring type counters. 3FE-46922-AAAA-TCZZA...
  • Page 57: Table 11 Package S Onts Ontenet Performance Monitoring Statistics

    R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide G-120W-F unit data sheet Table 11 Package S ONTs ONTENET performance monitoring statistics ONTENET statistics ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓...
  • Page 58: G-120W-F Functional Blocks

    R05.06.01 | June 2017 | Edition 01 G-120W-F unit data sheet 7368 ISAM ONT G-120W-F Product Guide Table 14 Package S ONTs PONONTTC aggregate performance monitor- ing statistics PONONTTC (aggregate) statistics G-120W-F ✓ ✓ ✓ ✓ ✓ Note A 5 second polling window limitation exists on the ONT, therefore the margin of error for each 15-min window is 5 seconds 5.9 G-120W-F functional blocks...
  • Page 59: Figure 17 Single-Residence Wi-Fi Ont With Gigabit Ethernet And Pots And Without Rf Video

    R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide G-120W-F unit data sheet Figure 17 Single-residence Wi-Fi ONT with Gigabit Ethernet and POTS and without RF video WIFI PCI-E Transformer 1GE+1*100M 1000 RJ45 + 100M RJ45...
  • Page 60: Figure 18 G-120W-F Ont Hardware Block

    R05.06.01 | June 2017 | Edition 01 G-120W-F unit data sheet 7368 ISAM ONT G-120W-F Product Guide Figure 18 G-120W-F ONT hardware block POTS ports Control processor SoC Bridge Ethernet GPON MACs Ethernet ports GPON 19421 ONT SoC technology consists of five key elements: •...
  • Page 61: G-120W-F Standards Compliance

    R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide G-120W-F unit data sheet These ONTs can also interact with additional hardware components to support functionality not provided by the SoC technology. 5.10 G-120W-F standards compliance G-120W-F indoor ONTs are compliant with the following standards: •...
  • Page 62: Energy-Related Products Standby And Off Modes Compliance

    5.10.1 Energy-related products standby and off modes compliance Hereby, Nokia declares that the G-120W-F ONTs are in compliance with the essential requirements and other relevant provisions of Directive 2009/125/EC together with Commission Regulation (EC) No 1275/2008 and Commission Regulation (EC) No 801/2013.
  • Page 63: Wi-Fi Physical Features

    R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide G-120W-F unit data sheet 5.11.1.1 Wi-Fi physical features G-120W-F indoor ONTs have the following physical features that assist in providing Wi-Fi service: • WLAN button for enabling and disabling Wi-Fi service •...
  • Page 64 R05.06.01 | June 2017 | Edition 01 G-120W-F unit data sheet 7368 ISAM ONT G-120W-F Product Guide Considerations and limitations The following voice features / GSIP parameters are configurable on a per-Client/ per-ONT basis (not per-Subscriber): • Enable Caller ID and Enable Caller Name ID •...
  • Page 65: Install A G-120W-F Indoor Ont

    R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide Install a G-120W-F indoor ONT 6 Install a G-120W-F indoor ONT 6.1 Purpose 6.2 General 6.3 Prerequisites 6.4 Recommended tools 6.5 Safety information 6.6 Procedure 6.1 Purpose This chapter provides the steps to install a G-120W-F indoor ONT.
  • Page 66: Safety Information

    R05.06.01 | June 2017 | Edition 01 Install a G-120W-F indoor ONT 7368 ISAM ONT G-120W-F Product Guide • drill and drill bits • paper clip 6.5 Safety information Read the following safety information before installing the unit. Hazardous electrical voltages and currents can Danger 1 —...
  • Page 67: Procedure

    R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide Install a G-120W-F indoor ONT 6.6 Procedure Use this procedure to install a G-120W-F indoor ONT. Place the indoor ONT unit: On the flat surface, such as a desk or shelf; go to step 3.
  • Page 68: Figure 22 G-120W-F Indoor Ont Connections

    R05.06.01 | June 2017 | Edition 01 Install a G-120W-F indoor ONT 7368 ISAM ONT G-120W-F Product Guide The recommended length of mounting screw is 1.15 in. (3.8 cm). Do not drive the screw into the wall completely. Leave approximately 1/8 in. (6 mm) between the screw head and the wall surface.
  • Page 69 If used, enable the Wi-Fi service by pressing the WLAN button. If used, enable the WPS by pressing the WPS button. Verify the ONT LEDs, voltage status, and optical signal levels; see the 7368 Hardware and Cabling Installation Guide. Activate and test the services; see the 7368 Hardware and Cabling Installation Guide.
  • Page 70 R05.06.01 | June 2017 | Edition 01 Install a G-120W-F indoor ONT 7368 ISAM ONT G-120W-F Product Guide 3FE-46922-AAAA-TCZZA Issue: 01...
  • Page 71: Replace A G-120W-F Indoor Ont

    R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide Replace a G-120W-F indoor ONT 7 Replace a G-120W-F indoor ONT 7.1 Purpose 7.2 General 7.3 Prerequisites 7.4 Recommended tools 7.5 Safety information 7.6 Procedure 7.1 Purpose This chapter provides the steps to replace G-120W-F indoor ONTs.
  • Page 72: Safety Information

    R05.06.01 | June 2017 | Edition 01 Replace a G-120W-F indoor ONT 7368 ISAM ONT G-120W-F Product Guide • optical power meter • drill and drill bits 7.5 Safety information Read the following safety information before replacing the unit. Hazardous electrical voltages and currents can Danger 1 —...
  • Page 73: Procedure

    R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide Replace a G-120W-F indoor ONT 7.6 Procedure Use this procedure to replace a G-120W-F indoor ONT. Deactivate the ONT services at the P-OLT. If you are using the SLID feature, this step is not required. The ONT and the services can remain in service (IS).
  • Page 74 Connect the POTS cables directly to the RJ-11 ports as per local practices. If required, have approved service personnel who are trained to work with optic fiber clean the fiber optic connection. See the 7368 ISAM ONT Configuration, Management, and Troubleshooting Guide for more information about fiber optic handling, inspection, and cleaning.
  • Page 75 P-OLT; see the operations and maintenance documentation for the OLT for more details. Verify the ONT LEDs, voltage status, and optical signal levels; see the 7368 Hardware and Cabling Installation Guide. Activate and test the services; see the 7368 Hardware and Cabling Installation Guide.
  • Page 76 R05.06.01 | June 2017 | Edition 01 Replace a G-120W-F indoor ONT 7368 ISAM ONT G-120W-F Product Guide 3FE-46922-AAAA-TCZZA Issue: 01...
  • Page 77: Configure A G-120W-F Indoor Ont

    Please refer to the configuration information provided with your OLT for the software configuration procedure for a G-120W-F ONT. For HTTP configuration procedures, please refer to the 7368 ISAM ONT Configuration, Management, and Troubleshooting Guide. 8.2 HGU mode GUI configuration Use the procedures below to use the web-based GUI for the G-120W-F in HGU mode.
  • Page 78: Device And Connection Status

    R05.06.01 | June 2017 | Edition 01 Configure a G-120W-F indoor ONT 7368 ISAM ONT G-120W-F Product Guide The default gateway IP address is http://192.168.1.254. You can connect to this IP address using your web browser after connecting your PC to one of Ethernet ports of the ONT. The static IP address of your PC must be in the same subnet as the ONT.
  • Page 79: Figure 25 Device Information Window

    R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide Configure a G-120W-F indoor ONT • optics module status • statistics • voice information Procedure 7 Device information retrieval Select Status > Device Information from the top-level menu in the GPON Home Gateway window, as shown in Figure 25.
  • Page 80 R05.06.01 | June 2017 | Edition 01 Configure a G-120W-F indoor ONT 7368 ISAM ONT G-120W-F Product Guide Field Description Device Running Time Amount of time the device has run since last reset in hours, minutes, and seconds (2 of 2) Click Refresh to update the displayed information.
  • Page 81: Figure 26 Lan Status Window

    R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide Configure a G-120W-F indoor ONT Procedure 8 LAN status retrieval Select Status > LAN Status from the top-level menu in the GPON Home Gateway window, as shown in Figure 26.
  • Page 82: Table 17 Lan Status Parameters

    R05.06.01 | June 2017 | Edition 01 Configure a G-120W-F indoor ONT 7368 ISAM ONT G-120W-F Product Guide Table 17 LAN status parameters Field Description Wireless Information Wireless Status Indicates whether the wireless is on or off Wireless Channel Wireless channel number...
  • Page 83: Figure 27 Wan Status Window

    R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide Configure a G-120W-F indoor ONT Click Refresh to update the displayed information. STOP. This procedure is complete. Procedure 9 WAN status retrieval Select Status > WAN Status from the top-level menu in the GPON Home Gateway window, as shown in Figure 27.
  • Page 84 R05.06.01 | June 2017 | Edition 01 Configure a G-120W-F indoor ONT 7368 ISAM ONT G-120W-F Product Guide Field Description WAN Link Status Whether the WAN link is up or down Pon Link Status Whether the PON link is up or down...
  • Page 85: Figure 28 Wan Status Ipv6 Window

    R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide Configure a G-120W-F indoor ONT Procedure 10 WAN status IPv6 retrieval Select Status > WAN Status IPv6 from the top-level menu in the GPON Home Gateway window, as shown in Figure 28.
  • Page 86 R05.06.01 | June 2017 | Edition 01 Configure a G-120W-F indoor ONT 7368 ISAM ONT G-120W-F Product Guide Field Description IPv6 Gateway IPv6 gateway address Primary DNS Primary Domain Name Server Second DNS Secondary Domain Name Server Pon Link Status...
  • Page 87: Figure 29 Home Networking Information Window

    R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide Configure a G-120W-F indoor ONT Procedure 11 Home networking information retrieval Select Status > Home Networking from the top-level menu in the GPON Home Gateway window, as shown in Figure 29.
  • Page 88: Figure 30 Optics Module Status Window

    R05.06.01 | June 2017 | Edition 01 Configure a G-120W-F indoor ONT 7368 ISAM ONT G-120W-F Product Guide Click Refresh to update the displayed information. STOP. This procedure is complete. Procedure 12 Optics module status retrieval Select Status > Optics Module Status from the top-level menu in the GPON Home Gateway window, as shown in Figure 30.
  • Page 89: Figure 31 Lan Ports Statistics Window

    R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide Configure a G-120W-F indoor ONT Field Description Tx Optics Signal Level at 1310 nm (ONT Transmitted optics signal level at 1310 nm, ANI-ONT-Side Optical Measurements) measured in dBm...
  • Page 90: Figure 32 Voice Information Window

    R05.06.01 | June 2017 | Edition 01 Configure a G-120W-F indoor ONT 7368 ISAM ONT G-120W-F Product Guide If there are no WAN connections to display, the system displays a message to indicate that. STOP. This procedure is complete. Procedure 14 Voice information retrieval Select Status >...
  • Page 91: Network Configuration

    R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide Configure a G-120W-F indoor ONT Field Description Register Error Reason Error reason for the unregistered POTS port User Agent IP IP address of the user agent (2 of 2) Note This field is only visible at the adminGPON level;...
  • Page 92: Figure 33 Lan Network Window

    R05.06.01 | June 2017 | Edition 01 Configure a G-120W-F indoor ONT 7368 ISAM ONT G-120W-F Product Guide Procedure 15 LAN networking configuration Select Network > LAN from the top-level menu in the GPON Home Gateway window, as shown in Figure 33.
  • Page 93 R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide Configure a G-120W-F indoor ONT Field Description Port Mode: Port 1 - 4 Drop-down port mode for each port: Route mode or Bridge mode IPv4 Address IP Address of the ONT...
  • Page 94: Figure 34 Lan Ipv6 Network Window

    R05.06.01 | June 2017 | Edition 01 Configure a G-120W-F indoor ONT 7368 ISAM ONT G-120W-F Product Guide Procedure 16 LAN IPv6 networking configuration Select Network > LAN_IPv6 from the top-level menu in the GPON Home Gateway window, as shown in Figure 34.
  • Page 95 R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide Configure a G-120W-F indoor ONT Field Description Whether other info Select this checkbox to enable retrieval of other information through DHCP. obtained through DHCP Maximum interval for...
  • Page 96: Figure 35 Wan Network Window

    R05.06.01 | June 2017 | Edition 01 Configure a G-120W-F indoor ONT 7368 ISAM ONT G-120W-F Product Guide Procedure 17 WAN networking configuration Select Network > WAN from the top-level menu in the GPON Home Gateway window, as shown in Figure 35.
  • Page 97: Figure 36 Wan Dhcp Window

    R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide Configure a G-120W-F indoor ONT Field Description Manual DNS Enter a manual DNS (2 of 2) Configure a specific WAN connection. Click Save. STOP. This procedure is complete.
  • Page 98: Table 26 Wan Dhcp Parameters

    R05.06.01 | June 2017 | Edition 01 Configure a G-120W-F indoor ONT 7368 ISAM ONT G-120W-F Product Guide Table 26 WAN DHCP parameters Field Description WAN Connection List Choose a WAN connection from the drop-down menu DHCP Option 50 persistent...
  • Page 99: Figure 37 Wireless 2.4Ghz Network Window

    R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide Configure a G-120W-F indoor ONT Procedure 19 Wireless 2.4GHz networking configuration Select Network > Wireless 2.4GHz from the top-level menu in the GPON Home Gateway window, as shown in Figure 37.
  • Page 100 R05.06.01 | June 2017 | Edition 01 Configure a G-120W-F indoor ONT 7368 ISAM ONT G-120W-F Product Guide Field Description Mode Choose a Wi-Fi mode from the drop-down menu: • auto (b/g/n) • • • • Bandwidth Choose from: •...
  • Page 101: Wireless Scheduling

    R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide Configure a G-120W-F indoor ONT When Encryption Mode is set to “WPA/WPA2 Enterprise”, the following options become available: Primary RADIUS server, port and password; Secondary RADIUS server, port, and password; RADIUS accounting port.
  • Page 102: Ip Routing Configuration

    R05.06.01 | June 2017 | Edition 01 Configure a G-120W-F indoor ONT 7368 ISAM ONT G-120W-F Product Guide Enter a start time and end time for the period in which you want the wireless signal off. Choose Everyday or Individual Days from the drop-down menu.
  • Page 103: Table 28 Ip Routing Network Parameters

    R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide Configure a G-120W-F indoor ONT Table 28 IP Routing network parameters Field Description Enable Routing Select this checkbox to enable routing Destination IP Address Enter the destination IP address...
  • Page 104: Figure 40 Dns Network Window

    R05.06.01 | June 2017 | Edition 01 Configure a G-120W-F indoor ONT 7368 ISAM ONT G-120W-F Product Guide Procedure 22 DNS configuration Select Network > DNS from the top-level menu in the Home Gateway window, as shown in Figure 40.
  • Page 105: Figure 41 Tr-069 Network Window

    R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide Configure a G-120W-F indoor ONT If required, associate an original domain with a new domain, click Add. STOP. This procedure is complete. Procedure 23 TR-069 configuration Select Network > TR-069 from the top-level menu in the GPON Home Gateway window, as shown in Figure 41.
  • Page 106: Qos Configuration

    R05.06.01 | June 2017 | Edition 01 Configure a G-120W-F indoor ONT 7368 ISAM ONT G-120W-F Product Guide Field Description Connect Request Password Password used to log in to the auto-configuration server (2 of 2) Configure TR-069 by entering the required information.
  • Page 107: Security Configuration

    R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide Configure a G-120W-F indoor ONT Table 31 QoS Config parameters Field Description Type Choose a QoS service layer type from the drop-down menu L2 or L3. Source MAC Enter the source MAC.
  • Page 108: Figure 43 Firewall Window

    R05.06.01 | June 2017 | Edition 01 Configure a G-120W-F indoor ONT 7368 ISAM ONT G-120W-F Product Guide • parental control • DMZ and ALG • access control Procedure 25 Firewall configuration Select Security > Firewall from the top-level menu in the GPON Home Gateway window, as shown in Figure 43.
  • Page 109: Table 32 Firewall Parameters

    R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide Configure a G-120W-F indoor ONT Table 32 Firewall parameters Field Description Security level Choose the security level from the drop-down menu: low, medium, or high Attack Protect...
  • Page 110: Figure 45 Ip Filter Window

    R05.06.01 | June 2017 | Edition 01 Configure a G-120W-F indoor ONT 7368 ISAM ONT G-120W-F Product Guide Table 33 MAC filter parameters Field Description Enable MAC filter Select this checkbox to enable the MAC filter Mac Address Select a MAC address from the drop-down menu or enter the address in the text field...
  • Page 111: Table 34 Ip Filter Parameters

    R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide Configure a G-120W-F indoor ONT Table 34 IP filter parameters Field Description Enable IP Filter Select this checkbox to enable an IP filter Mode Choose an IP filter mode from the drop-down menu: •...
  • Page 112: Figure 46 Url Filter Window

    R05.06.01 | June 2017 | Edition 01 Configure a G-120W-F indoor ONT 7368 ISAM ONT G-120W-F Product Guide Procedure 28 URL filter configuration Select Security > URL Filter from the top-level menu in the GPON Home Gateway window, as shown in Figure 46.
  • Page 113: Figure 47 Parental Control Window

    R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide Configure a G-120W-F indoor ONT You can configure up to 100 URL filters. STOP. This procedure is complete. Procedure 29 Parental control Select Security > Parent Control from the top-level menu in the EPON Home Gateway window, as shown in Figure 47.
  • Page 114: Figure 48 Dmz And Alg Window

    R05.06.01 | June 2017 | Edition 01 Configure a G-120W-F indoor ONT 7368 ISAM ONT G-120W-F Product Guide Select the Access Control checkbox. Click the plus sign (+) to add a policy. A separate panel displays for configuring the policy name, IP address of the device, and dates and times for the policy.
  • Page 115: Table 37 Dmz And Alg Parameters

    R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide Configure a G-120W-F indoor ONT Table 37 DMZ and ALG parameters Field Description ALG Config Select the checkboxes to enable the protocols to be supported by the ALG: FTP,...
  • Page 116: Access Control Configuration

    R05.06.01 | June 2017 | Edition 01 Configure a G-120W-F indoor ONT 7368 ISAM ONT G-120W-F Product Guide Procedure 31 Access control configuration This procedure describes how to configure the access control level (ACL). Note 1 — ACL takes precedence over the firewall policy.
  • Page 117: Application Configuration

    R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide Configure a G-120W-F indoor ONT Field Description Source IP End Enter an end IP address for the new subnet trusted network (2 of 2) Select a WAN connection from the drop-down menu.
  • Page 118: Port Forwarding Configuration

    R05.06.01 | June 2017 | Edition 01 Configure a G-120W-F indoor ONT 7368 ISAM ONT G-120W-F Product Guide Procedure 32 Port forwarding configuration Select Application > Port forwarding from the top-level menu in the GPON Home Gateway window, as shown in Figure 50.
  • Page 119: Figure 51 Port Triggering Window

    R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide Configure a G-120W-F indoor ONT Click Add. STOP. This procedure is complete. Procedure 33 Port triggering Select Application > Port Triggering from the top-level menu in the GPON Gateway window, as shown in Figure 51.
  • Page 120: Ddns Configuration

    R05.06.01 | June 2017 | Edition 01 Configure a G-120W-F indoor ONT 7368 ISAM ONT G-120W-F Product Guide Field Description Open Protocol Choose the open port protocol from the drop-down menu: • • • TCP/UDP Trigger Protocol Choose the triggering port protocol from the drop-down menu: •...
  • Page 121: Ntp Configuration

    R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide Configure a G-120W-F indoor ONT Table describes the fields in the DDNS window. Table 41 DDNS parameters Field Description WAN Connection List Choose a WAN connection from the drop-down menu...
  • Page 122: Figure 54 Upnp And Dlna Window

    R05.06.01 | June 2017 | Edition 01 Configure a G-120W-F indoor ONT 7368 ISAM ONT G-120W-F Product Guide Select the Enable NTP Service checkbox to enable NTP service. Click Save. STOP. This procedure is complete. Procedure 36 UPnP and DLNA configuration Select Application >...
  • Page 123: Figure 55 Voice Setting Window

    R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide Configure a G-120W-F indoor ONT Procedure 37 Voice setting Select Application > Voice Setting from the top-level menu in the EPON Home Gateway window, as shown in Figure 55.
  • Page 124: Maintenance

    R05.06.01 | June 2017 | Edition 01 Configure a G-120W-F indoor ONT 7368 ISAM ONT G-120W-F Product Guide Table describes the fields in the Voice Setting window. Table 42 Voice setting parameters Field Description Outbound Proxy Enter the SIP outbound proxy...
  • Page 125: Figure 56 Password Window

    R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide Configure a G-120W-F indoor ONT • backup and restore • upgrade firmware • reboot device • restore factory defaults • diagnose WAN connections • Procedure 38 Password configuration Select Maintenance >...
  • Page 126: Figure 57 Speed Test Window

    R05.06.01 | June 2017 | Edition 01 Configure a G-120W-F indoor ONT 7368 ISAM ONT G-120W-F Product Guide Click Save. STOP. This procedure is complete. Procedure 39 WAN speed test Select Maintenance > Speed Test from the top-level menu in the GPON Home Gateway window, as shown in Figure 57.
  • Page 127: Figure 58 Loid Config Window

    R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide Configure a G-120W-F indoor ONT Procedure 40 LOID configuration Select Maintenance > LOID Config from the top-level menu in the GPON Home Gateway window, as shown in Figure 58.
  • Page 128: Figure 59 Slid Configuration Window

    R05.06.01 | June 2017 | Edition 01 Configure a G-120W-F indoor ONT 7368 ISAM ONT G-120W-F Product Guide Procedure 41 SLID configuration Select Maintenance > SLID Configuration from the top-level menu in the GPON Home Gateway window, as shown in Figure 59.
  • Page 129: Figure 60 Device Management Window

    R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide Configure a G-120W-F indoor ONT Click Save. STOP. This procedure is complete. Procedure 42 Device management Select Maintenance > Device Management from the top-level menu in the GPON Home Gateway window, as shown in Figure 60.
  • Page 130: Figure 61 Backup And Restore Window

    R05.06.01 | June 2017 | Edition 01 Configure a G-120W-F indoor ONT 7368 ISAM ONT G-120W-F Product Guide Click Add. STOP. This procedure is complete. Procedure 43 Backup and restore Select Maintenance > Backup and Restore from the top-level menu in the GPON Home Gateway window, as shown in Figure 61.
  • Page 131: Figure 62 Firmware Upgrade Window

    R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide Configure a G-120W-F indoor ONT Procedure 44 Upgrade firmware Select Maintenance> Firmware Upgrade from the top-level menu in the GPON Home Gateway window, as shown in Figure 62.
  • Page 132: Figure 63 Reboot Window

    R05.06.01 | June 2017 | Edition 01 Configure a G-120W-F indoor ONT 7368 ISAM ONT G-120W-F Product Guide Procedure 45 Reboot ONT Select Maintenance > Reboot Device from the top-level menu in the GPON Home Gateway window, as shown in Figure 63.
  • Page 133: Figure 64 Factory Default Window

    R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide Configure a G-120W-F indoor ONT Procedure 46 Restore factory defaults Select Maintenance > Factory Default from the top-level menu in the GPON Home Gateway window, as shown in Figure 64.
  • Page 134: Figure 65 Diagnostics Window

    R05.06.01 | June 2017 | Edition 01 Configure a G-120W-F indoor ONT 7368 ISAM ONT G-120W-F Product Guide Procedure 47 Diagnose WAN connections Select Maintenance > Diagnostics from the top-level menu in the GPON Home Gateway window, as shown in Figure 65.
  • Page 135: View Log Files

    R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide Configure a G-120W-F indoor ONT Click Cancel to cancel the test. STOP. This procedure is complete. Procedure 48 View log files Select Maintenance > Log from the top-level menu in the GPON Home Gateway window, as shown in Figure 66.
  • Page 136: Rg Troubleshooting Counters

    R05.06.01 | June 2017 | Edition 01 Configure a G-120W-F indoor ONT 7368 ISAM ONT G-120W-F Product Guide Choose a reading level from the drop-down menu to determine which types of events to display from the log file: • Emergency •...
  • Page 137: Figure 67 Rg Troubleshooting Counters Window

    R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide Configure a G-120W-F indoor ONT Figure 67 RG Troubleshooting Counters window Table describes the fields in the RG Troubleshooting Counters window. Table 47 RG Troubleshooting Counters parameters...
  • Page 138: Sfu Mode Gui Configuration

    R05.06.01 | June 2017 | Edition 01 Configure a G-120W-F indoor ONT 7368 ISAM ONT G-120W-F Product Guide Field Description Latency Click Latency Test to specify the time for the test The default is weekly, performed at idle to a public server...
  • Page 139: Device And Connection Status

    R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide Configure a G-120W-F indoor ONT Enter your username and password in the Log in window, as shown in Figure 68. The default username is adminadmin. The default password is ALC#FGU.
  • Page 140: Figure 69 Device Information Window

    R05.06.01 | June 2017 | Edition 01 Configure a G-120W-F indoor ONT 7368 ISAM ONT G-120W-F Product Guide Procedure 51 Device information retrieval Select Status > Device Information from the top-level menu in the SFU GPON Home Gateway window, as shown in Figure 69.
  • Page 141: Figure 70 Optics Module Status Window

    R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide Configure a G-120W-F indoor ONT Click Refresh to update the displayed information. STOP. This procedure is complete. Procedure 52 Optics module status retrieval Select Status > Optics Module Status from the top-level menu in the SFU GPON Home Gateway window, as shown in Figure 70.
  • Page 142: Network Configuration

    R05.06.01 | June 2017 | Edition 01 Configure a G-120W-F indoor ONT 7368 ISAM ONT G-120W-F Product Guide Field Description Lower (ONT ANI-ONT-Side Optical Lower optical threshold, measured in dBm Measurements-Optical Threshold) Upper (ONT ANI-ONT-Side Optical Lower optical threshold, measured in dBm...
  • Page 143: Maintenance

    R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide Configure a G-120W-F indoor ONT Click the plus sign (+) to add a scheduling rule. A separate panel displays for configuring wireless schedule rules. Enter a start time and end time for the period in which you want the wireless signal off.
  • Page 144: Figure 72 Password Window

    R05.06.01 | June 2017 | Edition 01 Configure a G-120W-F indoor ONT 7368 ISAM ONT G-120W-F Product Guide Procedure 54 Password configuration Select Maintenance > Password from the top-level menu in the SFU GPON Home Gateway window, as shown in Figure 72.
  • Page 145: Figure 73 Loid Authentication Window

    R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide Configure a G-120W-F indoor ONT Procedure 55 LOID configuration Select Maintenance> LOID Config from the top-level menu in the SFU GPON Home Gateway window, as shown in Figure 73.
  • Page 146: Operator Id

    R05.06.01 | June 2017 | Edition 01 Configure a G-120W-F indoor ONT 7368 ISAM ONT G-120W-F Product Guide Procedure 56 SLID configuration Select Maintenance > SLID Configuration from the top-level menu in the SFU GPON Home Gateway window, as shown in Figure 74.
  • Page 147 R05.06.01 | June 2017 | Edition 01 7368 ISAM ONT G-120W-F Product Guide Configure a G-120W-F indoor ONT Procedure 57 Modifying the operator ID Register the ONT with the OLT. Check the original OPID. Update the OntConfig.xml file by adding-the following content: <OperatorObject version=”1.0”>...
  • Page 148 R05.06.01 | June 2017 | Edition 01 Configure a G-120W-F indoor ONT 7368 ISAM ONT G-120W-F Product Guide 3FE-46922-AAAA-TCZZA Issue: 01...
  • Page 149: Ont Configuration File Over Omci

    This feature is supported for use with the 7360 ISAM Note — FX and the 7342 ISAM FTTU. 9.2 Supported configuration file types Table describes the configuration file types that are supported from 7368 ISAM ONT R05.02.00 and later. Issue: 01 3FE-46922-AAAA-TCZZA...
  • Page 150: Table 53 Supported Configuration Files

    Note: the pre-configuration file does not work with SFU ONTs; therefore, this feature applies only to Residential Gateway ONTs. The pre-configuration file can be used as is, but Nokia provides its customers with the flexibility to customize the pre-configuration file.
  • Page 151: Filename Conventions

    9.2.1 Filename conventions Nokia provides the raw configuration files, which must be saved by the operator in a TAR file to be uploaded. TAR file names must be unique. The filenames of the raw configuration files may not adhere to the naming conventions outlined below.
  • Page 152 Configuring an ONT using a configuration file via OMCI Generate the TAR file to be uploaded to the OLT. Using the raw configuration file(s) provided by Nokia, generate the TAR file as follows: On a Linux platform, rename the raw configuration file to adhere to the naming convention, as described in section 9.2.
  • Page 153 XMLXXXXXX1 Configure equipment interface … pland-cfgfile2=XMLXXXXXX2 and dnload-cfgfile2 XMLXXXXXX2 Although the OLT permits the above two steps without reporting an error, Nokia does not recommend executing them, because the ONT may exhibit unexpected behavior. If pland-cfgfileX=Auto and dnload-cfgfileX= Auto The OLT will download the XML file from "sw-ctr-list"...
  • Page 154 R05.06.01 | June 2017 | Edition 01 ONT configuration file over OMCI 7368 ISAM ONT G-120W-F Product Guide 3FE-46922-AAAA-TCZZA Issue: 01...
  • Page 155: Customer Document And Product Support

    R05.06.01 | June 2017 | Edition 01 Customer document and product support Customer documentation Customer Documentation Welcome Page Technical Support Customer Documentation Technical Support Documentation feedback Customer Documentation Feedback...
  • Page 156 R05.06.01 | June 2017 | Edition 01 Copyright 2017 Nokia. 3FE-46922-AAAA-TCZZA...

This manual is also suitable for:

7368 isam ont g-120w-f

Table of Contents