Concrete pad installation for SW-300..........Concrete pad installation for SW-350..........Operator & Arm Installation..........11, 13&15 Compact Installation for SW-300 & SW-350........Torque limiter and arm adjustment..........Gate travel adjustment..............21 Left hand and right hand opening settings........24& Electrical power connections............
IMPORTANT SAFETY INSTRUCTIONS WARNING To reduce the risk of injury: READ THE FOLLOWING DIRECTIONS. DO NOT EVEN THINK OF STARTING UNTIL YOU HAVE READ AND UNDERSTAND THESE DIRECTIONS. IF THERE IS SOMETHING YOU DO NOT UNDERSTAND CALL US. Never let children operate or play with gate controls. Keep the remote control away from children.
Page 4
INSTALL THE GATE OPERATOR ONLY WHEN YOU HAVE READ THE FOLLOWING: *Confirm that the gate operator being installed is appropriate for the application. *Confirm that the gate is designed and built according to current published industry standards. *Confirm that all appropriate safety features and safety accessory devices are being incorporated, including both primary and secondary entrapment protection devices.
Inherent adjustable clutch or pressure relief valve. Type D: Provision for connection of or provided with and actuation device requiring continuous pressure. Type E: Inherent audio alarm. All of All-O-Matic Inc’s Gate operators conform to the most ridged Class One...
Page 6
CIMIENTO DE CONCRETO PARA EL CONCRETE PAD FOR SW-300 Cubierta plástica del Tornillo de anclaje operador 4 lugares ½”X3 ½” Operator plastic Cover Four red head Bolts ” ” 24” 13 ” Area for Conduit(s) Area para las pipas de conducto Cimiento de concreto Chasis del para el operador...
CIMIENTO DE CONCRETO PARA EL CONCRETE PAD FOR SW-350 Cubierta plástica del operador Operator plastic Tornillo de anclaje Cover 4 lugares ½”X3 ½” Four red head Bolts ” ” Area for Conduit(s) 9” 24” Area para las pipas de conducto...
Page 8
OPERATOR AND ARM DIMENTIONS HINGE CENTER POST OUTSIDE INSIDE Refer to This distance is from the gate in open note 2” position to edge of the below. pad. Refer to note CONCRETE PAD Dimentions Chart Gate Minimum length Distance Less than 12”...
Page 9
OPERATOR AND ARM LAYOUT Hinge point “A” Point Mark ground under Bracket gate bracket with Bracket gate closed. This will be point Point Mark ground under gate bracket with gate open. This will 14” be point Bracket Hinge point Point Bracket Point Draw a line from point...
Page 10
ARM LAYOUT & OPERATOR PLACEMENT CONTINUED Bracket Hinge point Point Bracket Point Measure distance from the point And point Say distance is 60”, divide this number by 2,which =30”. This is the length of primary arm in next drawing. PLEASE BE EXACT!!! Center shaft of Operator This ARM section is half the...
Page 11
SWINGER COMPACT INSTALLATON To use this installation the gate must be 12’ or less. HINGE CENTER 27” OUTSIDE INSIDE 8” 35” 20” Use these measurements, only if the distance between the wall and the gate in the open position is 20” to 34”. If you have more than 34”...
2200 uF 2200 uF 2200 u 2200 u Top view SW-300 SW-350 Use a pad lock or ARM ADJUSTMENT: MASTER a bolt to hold the arm lever in closed position. With the arm lever closed tighten the arm adjusting screw as tight as possible.
GATE TRAVEL ADJUSTMENT Locate limit switch. Step 1: Turn the power off on operator. Step 2: Use an allen wrench to loosen up the limit cams. Turn the limit Cams to desired direction. Step 3: tighten the allen screw. Step 4: Turn the operator back on. Step 5: Run gate operator.
Page 14
LEFT HAND OPENING SETTINGS See chart below for specific operator model wiring direction. Use these wire settings for SW-300 & SW-350 opening direction IMPORTANT: This setting is for Limit wires Motor wires left hand opening. SW-300 SW-300 Be sure to follow the...
Page 15
RIGHT HAND OPENING SETTINGS See chart below for specific operator model wiring direction. Use these wire settings for SW-300 & SW-350 opening direction Limit wires Motor wires IMPORTANT: SW-300 SW-300 This setting is for right hand opening. C-LIMIT = wire...
ELECTRICAL CONNECTION OPERATORS BE PROPERLY GROUNDED! MUST Power switch and electrical connection box. For power wires enclosure use UL listed conduits. Connect black wire to 115 volts AC = Hot. For power, a minimum of a 20-Amp dedicated Connect white wire to AC = Neutral. circuit breaker is needed.
PER FOOT Exit loop Exit loop WHEN USED This is a normal loop layout. Remember when connecting to an All-O-Matic circuit board you use the normally closed for your safety loop detector and contacts normally from the exit loop. You must twist your...
ACCESSORY CONNECTIONS The circuit board 24-VAC output provides up to 700 mAmps of power for accessories. More than two or three accessories will require a separate power supply. Remove black jumper from SAFETY when a safety device is Power Detect installed.
Page 19
MULTIPLE SAFETY DEVICES CONNECTIONS Multiple SAFETY devices installed together must be connected “ in series ” Locate the normally closed (N.C.) dry contact from each accessory relay. Also, b efore installing the accessory devices, remove the black wire jumper from the SAFETY terminal position on the terminal strip of the control board.
LEADING EDGE CONNECTION PHILIPS PHILIPS PHILIPS Connect one of the wires from leading edge to connector on control board. Connect the other wire from leading edge to EDGE connector control board LEADING EDGE SENSOR...
Page 21
PRE-WIRED LOOP INSTALLATION SW-350 Model SW-350 provides three pre-wired loop harnesses one for SAFETY LOOP one for PHANTOM and one for EXIT LOOP. Loop detectors must be 120 VAC. To install loop detectors make sure power is off in main power source then...
EMERGENCY RELEASE SW-350 Procedures to release gate: 1. Turn power OFF. 2. Push pedal down & move pedal lightly to the right to hold pedal down in position 3. Push gate open. EXIT ® 115VAC SAFETY...
Page 23
THREE BUTTON STATION SYSTEM See push button connections below. Terminal strip Connect the COMMON from all the push buttons to 24V- COM on the PED-SW terminal strip. Jumper OPEN N.O. Connect OPEN push button N.O. contact to EXIT LOOP on the terminal strip.
MASTER/SLAVE CONNECTION Before connecting master/slave gate operators together, test and adjust limit switches and the ERDs for each operator as “ stand alone ” machines. All accessories must be installed on the master board, no exception. See page 53 for dip switch settings. Use a two wire and run it through a UL listed conduit for shielded cable...
MAGNETIC/SOLENOID LOCK CONNECTIONS Magnetic lock installation requires a step down transformer with appropriate voltage for the specific lock accessory. AC-N LOCK from terminal strip supply 110 volts to power the transformer and control the locks’. Connect low voltage wires from transformer directly to the lock as shown below.
RADIO RECEIVER CONNECTIONS 3 wire receiver mounts on receiver strip outside control box as shown below. 4 wire receiver :connect the two grey wires to & terminals on receiver strip outside control box. Connect black wire to 24 V-COM and red wire 24VAC on main control...
Pin # SL-100 The gate operator ERDs must be SW-300 adjusted so that the gate provides OH-200 regular, reliable and safe cycles. SL-150 3/4 & 1 SL-150 ERD must be checked every six SL-150 months. ½ SW-350 3/4 & 1 SW-350...
TIMER ADJUSTMENT TIMER ON: Timer to close, can be set from 1 to 60 seconds. TIMER OFF: Gate operation is push button to open, push button to close. OVERRIDE THE TIMER: Turn the RADIO switch to the “ON” position. This will allow the radio receiver to close the gate before the timer. TIMER adjustment Turn potentiometer counter clockwise for more time.
DIP SWITCH FUNCTIONS TIMER switch “ ” activates the TIMER. See page TIMER TIMER for details. RADIO RADIO switch “ ” allows the radio receiver RADIO to override the timer. See page for details. LOCK 1-PASS SLAVE switch “ ” allows the radio receiver to top and reverse the gate n any direction.
SWINGER ARM PARTS 3 SET SCREWS PIPE KNUCKLES QUICK RELEASE ARM PIPE ARM 3 SET SCREWS GATE BRACKET PRIMARY FLAT BAR ®...
Page 31
The SW-350 is our highest duty rated operator and the most powerful continuous duty operator available in the market today. The SW-350 has a foot pedal release in the event of a power failure. The SW-300 is our most popular gate operator. It is continuos duty for light commercial and residential use.