Advertisement

Quick Links

WPC-3000, WPC-4000, WPC-5000
Owner's Manual
Please read and save these instructions. Read carefully before attempting to assemble,
install, operate, or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with
instructions could result in personal injury and / or property damage! Retain instructions
for future reference.
Portable Air Conditioners
Descripti on
Thank you for selecti ng this Koldwave Portable Air Conditi oner.
Please read this manual before installing the 7KK14, 7KK17, or
7KK21 unit as it provides important informati on that should be
followed during installati on and maintenance. This will allow you
to correctly set up your system for maximum safety and perfor-
mance.
These units uti lize a dedicated spot cooling thermostat that will
provide you with spot cooling for large areas where cooling of
an enti re area is not practi cal or possible. These air conditi on-
ers can also be used in smaller areas for room cooling. Suitable
applicati ons include: a factory or workplace, industrial kitchen,
computer room, emergency cooling, outdoor events, etc. A con-
trol panel with display provides ease of use and contains a self-
diagnosti c functi on. The display shows operati ng modes, room
and set temperatures, and faults. If abnormal operati on occurs,
a visual display of the fault is shown. Caster wheels are included
for easy portability.
If you experience a problem with your unit, please refer to the troubleshooti ng secti on
of this manual to correct the problem (see page XX). If the problem is not corrected,
please collect informati on so that the Technical Support personal can more eff ecti vely
assist you. Technical Service can be reached by calling (413)564-5530 or emailing tech-
nicalservice@koldwave.com.
1
Owner's Manual
7KK14/7KK17/7KK21
7KK14/7KK17/7KK21
7KK14/7KK17/7KK21
Figure 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 7KK14 and is the answer not in the manual?

Questions and answers

Summary of Contents for Koldwave 7KK14

  • Page 1 Portable Air Conditioners Descripti on Thank you for selecti ng this Koldwave Portable Air Conditi oner. Please read this manual before installing the 7KK14, 7KK17, or 7KK21 unit as it provides important informati on that should be followed during installati on and maintenance.
  • Page 2: Table Of Contents

    Specifications · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · Wiring Diagram (7KK14, 7KK21) · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · ·...
  • Page 3: Specifications

    Owner’s Manual 7KK14/7KK17/7KK21 Specifications Specifications Unit 7KK14 7KK17 7KK21 Power Supply V/Ph/Hz 115/1/60 230/1/60 Cooling Capacity BTU/hr 13,200 16,800 21,200 Power Consumption 1058 1740 2200 Rated Current 15.8 10.9 Nema Plug 5-15P 5-20P 6-15P Power Cord Guage Power Cord Length...
  • Page 4: Wiring Diagram (7Kk14, 7Kk21)

    COMP' N - 1 N - 2 Spark Arrestor Figure 1 - Circuit Wiring Diagram (7KK14, 7KK21) 1. 재질 : 은무데드롱 25미크론 2. 인쇄방법: 씨링인쇄 3. 인쇄색상: 흑색 1도 4. 표면처리: 라미네이팅(OPP코팅) 5. 인쇄기준 : 도면 및 설계 제공 필름...
  • Page 5: Wiring Diagram (7Kk17)

    Owner’s Manual 7KK14/7KK17/7KK21 Wiring Diagram WPC-4MP FC-S2.0 Power Remote FLOAT Control (Option) SWITCH DRAIN PUMP (Option) HIGH PRESSURE SWITCH PRESSURE TIMER DOWN (Option) SWITCH BLOWER COOL POWER (HP) (LP) OUT_TEMP SENSOR ICE_TEMP SENSOR IN_TEMP SENSOR (FUSE) MOTOR T (AC) S...
  • Page 6: General Safety Information

    Owner’s Manual 7KK14/7KK17/7KK21 General Safety Information Please read this manual carefully for instructions on correct installation and usage. Please read all safeguards. 1. Transport and store the unit in an upright position only. Leave unit in an upright position for at least 3 hours before first use.
  • Page 7 Owner’s Manual 7KK14/7KK17/7KK21 18. DO NOT unplug the unit by pulling on the electrical cord. Keep electrical cord away from heat sources and always completely unroll the cord to avoid overheating. If the power cord becomes damaged, contact a qualified repair technician or a qualified electrician to perform replacement or repair of the power cord, plug, or prongs.
  • Page 8: Unpacking

    Owner’s Manual 7KK14/7KK17/7KK21 31. Instructi ons and other text required by this standard shall be writt en in an offi cial language of the country in which the appliance is to be sold. 32. The dimensions of the space necessary for correct installati on of the appliance including the minimum permissible distances to adjacent structures 33.
  • Page 9: Assembly

    Owner’s Manual 7KK14/7KK17/7KK21 Assembly (7KK14, 7KK17, 7KK21) Cool air outlet hose Top fan exhaust fl ange Display / Control board Evaporater / fi lter Condenser / fi lter tank Guide bar for condensate water Electrical access panel Condensate water tank (Water level is...
  • Page 10: Installation

    Make sure the AC outlet is free of dirt, dust, oil, water, or any other foreign NOTE: material. The unit is equipped with an approved NEMA plug configuration. (7KK14: 5-15P, 7KK17: 5-20P, 7KK21: 6-15P) The appropriate outlet must be used for each plug type.
  • Page 11: Operation

    Owner’s Manual 7KK14/7KK17/7KK21 Operation CONTROL PANEL Figure 9 · Press the power button for 2 seconds to activate the product. · Press the power button for 2 seconds while driving to stop the product. · Self-diagnosis will be performed to test for abnormalities, after marking “VER”...
  • Page 12 Owner’s Manual 7KK14/7KK17/7KK21 1) Cooling mode · The basic operation is based on “out” control. (discharge temperature TH1) · On/off the operation of the compressor. (COOL ↔ BLOWER) · The set temperature cannot be changed and it operates which is set to 0 degrees Celsius.
  • Page 13 Owner’s Manual 7KK14/7KK17/7KK21 1) It is a mode that prevents the operation of the rest of the buttons except for power. · It can be operated and released by pressing for 2 seconds. ← ← Example of Example releasing it.
  • Page 14: Maintenance

    Owner’s Manual 7KK14/7KK17/7KK21 Maintenance FILTER CLEANING (See Figures 10 and 11) There are two filters in the unit. The evaporator filter is located at the front of the unit. The condenser filter is located at the side of the unit.
  • Page 15: Maintenance (Continued)

    Owner’s Manual 7KK14/7KK17/7KK21 Maintenance (Continued) – For your convenience, record the complete model number and product name (located on the Product Identification Plate), the purchase date, purchase location, serial number, and warranty period in the table below. – Also, attach your purchase receipt as proof of purchase to this instruction manual for future reference.
  • Page 16: Self-Diagnostic Alarm Codes

    Owner’s Manual 7KK14/7KK17/7KK21 SELF-DIAGNOSTIC ALARM CODES Alarm Display Problem Cause Corrective Action • Do not use the air • Ambient temperature conditioner if ambient is too high temperature is higher Compressor • Unstable voltage than 113°F overloaded supply • Contact a qualified •...
  • Page 17 Owner’s Manual 7KK14/7KK17/7KK21 SELF-DIAGNOSTIC ALARM CODES Alarm Display Problem Cause Corrective Action TH1(Outlet) Abnormal tempera- temperature sensor Contact a qualified service ture sensor value has a loose or broken agent connection TH2(Inlet) Abnormal tempera- temperature sensor Contact a qualified service...
  • Page 18: Troubleshooting Chart

    Owner’s Manual 7KK14/7KK17/7KK21 Troubleshooting chart Symptom Possible Cause(s) Corrective Action High water level in con- 1. Remove blockage from drain densate tank hose Water leakage 2. Remove any object stuck underneath the black panel underneath the water tank 1. Check the power supply 1.
  • Page 19: Shipping List

    Where and when the unit was purchased. Portable Air Conditioner d. All of the model information about your Koldwave e. Any information on the failure, including LED’s that may or may not be illuminated. f. A description of the protected equipment, including model numbers if possible.
  • Page 20: Limited Product Warranty

    Koldwave’s examination at its factory, are shown to be defective or at Koldwave’s option, the return of the purchase price to the purchaser. Correction of such defects by repair or replacement, or, at Koldwave’s option, the return of the purchase price shall constitute fulfillment of warranty obligations to the purchaser.
  • Page 21 Owner’s Manual 7KK14/7KK17/7KK21...
  • Page 22 Owner’s Manual 7KK14/7KK17/7KK21...
  • Page 23 Owner’s Manual 7KK14/7KK17/7KK21...
  • Page 24 Owner’s Manual 7KK14/7KK17/7KK21 For Koldwave warranty please visit http://koldwave.com/html/literature.asp KOLDWAVE 260 North Elm St. Westfield, Ma 01085, USA PH: 413-564-5530 Fax: 252-753-1953 www.koldwave.com 1D M Koldwave2303140301...

This manual is also suitable for:

7kk177kk21

Table of Contents