Nprintf; Syslogip - Cisco ATA186-I2 Administrator's Manual

Analog telephone adaptor
Table of Contents

Advertisement

Chapter 5
Parameters and Defaults

NPrintf

Description
Use this parameter to specify the IP address and port of a host to which all Cisco ATA debug messages
are sent. The program prserv.exe, which comes bundled with the Cisco ATA software, is needed to
capture the debug information.
Syntax
<HOST_IP>,<HOST_PORT>
Example
If the program prserv.exe is running on a host with IP address 192.168.2.170 and listening port 9001, set
NPrintf to 192.168.2.170.9001. This causes the Cisco ATA to send all debug traces to that IP address.
Value Type
Extended IP address
Default
0
Voice Configuration Menu Access Code
81

SyslogIP

Description
Use this parameter for diagnostic purposes; specify the IP address and port number to which the
Cisco ATA should send its syslog output information.
The program prserv.exe, which is included in all Cisco ATA software upgrade packages, can be used to
capture syslog information if you do not have a syslog server.
Syntax
<HOST_IPaddress>.<HOST_PORT>
Example
If you want to send syslog information to the host at IP address 192.168.2.170 and port number 514, do
the following:
Value Type
Extended IP address
Default
0.0.0.0.514
OL-4804-01
Configure the value of this parameter as 192.168.2.170.514
On your PC, run the command:
prserv 514
Cisco ATA 186 and Cisco ATA 188 Analog Telephone Adaptor Administrator's Guide for H.323 (version 3.0)
Diagnostic Parameters
5-61

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ata188-i2-aAta 186Ata 188

Table of Contents