4.9.3.
Use the test leads to measure the capacitance of the capacitor being tested and read the measurement value from the LCD display.
NOTE: When measuring large capacitances, stabilizing the reading takes some time and when measuring polarized capacitors, pay
attention to the corresponding polarity to avoid damaging the meter.
4.10.
FREQUENCY MEASUREMENT
4.10.1.
After powering on, the meter will automatically switch to "Auto" automatic measurement mode. Press the SEL button to switch to Hz
measurement mode.
4.10.2.
Connect the black test lead and the red test lead to the COM input jack and the VRHZ-II- input jack, respectively.
4.10.3.
Use the test leads to measure and read the measurement value from the LCD display.
4.11.
TEMPERATURE MEASUREMENT
4.11.1.
After powering on, the meter will automatically switch to "Auto" automatic measurement mode. Press the SEL button to switch to
temperature measurement mode.
4.11.2.
Connect the thermocouple's black input end and the red test lead to the COM input jack and the VRHZ-II- input jack, respectively. The
display will show the temperature value along with the Fahrenheit symbol.
4.11.3.
Read the measurement value from the LCD display.
4.12.
AC/DC CURRENT MEASUREMENT
4.12.1.
After powering on, the meter will automatically switch to "Auto" automatic measurement mode. Press the SEL button to switch to the
measurement mode, press again in the current mode to switch to AC current.
4.12.2.
Connect the black input end and the red test lead to the COM input jack and the mA input jack, respectively, for measurement in series
with the circuit.
4.12.3.
Read the measurement value from the LCD display. When measuring DC current, the display will also show the current polarity
connected to the red probe.
5. MAINTENANCE
NOTE: The meter contains NO serviceable parts. DO NOT remove rear cover.
5.1.
If any abnormality is observed with the meter and the test leads, it should be discontinued from use immediately and sent for repair.
5.2.
Ensure it is not used until it has been checked and found to be safe.
5.3.
When servicing the meter test leads, use only specified replacement parts.
To avoid electric shock or damage to the meter or user, DO NOT get the inside of the meter wet. Before cleaning or storing the meter
5.4.
disconnect the test leads and any other connections.
5.5.
Regularly clean the meter's case using a damp cloth and mild detergent. Avoid using abrasives or solvents. If the input jacks are dirty
or moist, they may impact readings.
5.6.
To clean the input jacks, turn off the meter and unplug all test leads from the input jacks. Remove any dirt from the jacks.
5.7.
Use a fresh cotton ball dampened with cleaner or lubricant to clean each jack. The lubricant prevents moisture-related contamination
of the jacks.
6. END OF LIFE
6.1.
When disposing of this item ensure you operate in accordance with local and national regulations. Also see and understand Footer
information below.
WEEE REGULATIONS
Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment
(WEEE). When the product is no longer required, it must be disposed of in an environmentally protective way. Contact your local solid
waste authority for recycling information.
ENVIRONMENT PROTECTION
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids
according to local regulations.
Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts
without prior notice.
Important: No Liability is accepted for incorrect use of this product.
Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim.
Sealey Group
Jack Sealey (EU) Ltd t/a Sealey Group, Farney Street, Carrickmacross, Co. Monaghan, A81 PK68 Ireland
Jack Sealey Ltd t/a Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk, IP32 7AR UK
01284 757500
sales@sealey.co.uk
© Jack Sealey Limited
www.sealey.co.uk
Original Language Version
REGISTER YOUR
PURCHASE HERE
MM03
Issue 2 (3)
06/05/25
Need help?
Do you have a question about the MM03 and is the answer not in the manual?