Advertisement

Quick Links

Network
Camera
Installation Manual
DC-D4831HRX
Powered by

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DC-D4831HRX-W and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Idis DC-D4831HRX-W

  • Page 1 Network Camera Installation Manual DC-D4831HRX Powered by...
  • Page 2: Before Reading This Manual

    Before reading this manual This is a basic installation manual for use of an IDIS network camera. Users who are using this product for the first time, as well as users with experience using comparable products, must read this operation manual carefully before use and heed to the warnings and precautions contained herein while using the product.
  • Page 3: Safety Precautions

    Before reading this manual Safety Precautions WARNING RISK OF ELECTRIC SHOCK DO NOT OPEN WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. Important Safeguards 1.
  • Page 4: Fcc Compliance Statement

    IDIS Co., Ltd. reserves all rights concerning this operation manual. Use or duplication of this operation manual in part or whole without the prior consent of IDIS Co., Ltd. is strictly prohibited. Contents of this operation manual are subject to change without prior notice for reasons such as functionality enhancements.
  • Page 5: Table Of Contents

    Table of Contents Part 1 – Introduction ......... 6 Product Features .
  • Page 6: Part 1 - Introduction

    Ethernet. • Two-way audio communication support for remote You can use the IDIS Discovery program to change audio dialog network camera settings or the IDIS Solution Suite • Video stream buffering to counter pre-/post-event...
  • Page 7 • Redundant firmware and auto recovery features for Remote monitoring and recording via multi streaming improved system stability are available using the IDIS Solution Suite Compact • Network-based integrated management of multiple program. For more information on using IDIS Solution Suite Compact, refer to its operation manual.
  • Page 8: Accessories

    Part 1 – Introduction Accessories Upon purchasing the product, check inside the box to make sure all the following accessories are included. Network Camera Terminal Blocks (2 ea.) Desiccant (3 ea.), double-sided tape (3 ea.) Allen Wrench Quick Guide Screws (3 ea.) Protect Connector Guide Pattern...
  • Page 9: Overview

    Part 1 – Introduction Overview Body Dome Cover IR LED Lens Factory Reset Button Wall/Ceiling Installation Hole Power Dome Cover Assembly Part Network Port Cable Rubber SD Memory Card Slot ➓ Alarm I/O, Audio I/O...
  • Page 10 When connecting the device which For more information on network connection setup, exceeds the specification limit, refer to the picture refer to the IDIS Discovery operation manual. (circuit) below. If used with an external inductive load(e.g. relay), The table below shows the network cable a diode must be connected in parallel with the specifications.
  • Page 11 Part 1 – Introduction input from an electrical switch, the signal must be I/O Connector higher than 4.3V from an NC switch or less than 0.3V from an NO switch and must last for longer than 0.5 seconds. • Audio - O (Out): Connect an amplifier to this port (line out).
  • Page 12: Factory Reset

    For more information on other devices comprising the releasing the reset button while the camera is turned overall system, refer to their respective installation on or using the IDIS Discovery program from a remote manuals. location. A factory reset will reboot the system. For more...
  • Page 13: Inserting A Sd Memory Card

    Part 1 – Introduction Installation Remove the dome cover. • Check the wall or ceiling to see if it needs to be reinforced. The camera may fall off if the wall or ceiling is not strong enough to support its weight. •...
  • Page 14 Part 1 – Introduction Pull the cable slightly and arrange the rubber as Attach the enclosed desiccant in the bottom to shown below. prevent moisture. Desiccant To pass through a thin cable or more than two cables, it is advised to finish it using silicon to make sure waterproofed perfectly.
  • Page 15: Angle Adjustment

    Part 1 – Introduction Angle Adjustment Closing the Dome Cover The lens can be rotated along three axes. Attach the double-sided tape to the desiccant first, and attach it to the specified position inside the dome cover as shown below. Check the location of drain hole and wall/ceiling installation hole.
  • Page 16: Dimension

    Part 1 – Introduction Dimension Fasten the screws for the dome cover clockwise using the Allen wrench provided with the camera. Ø 100mm Ø 155mm Remove the protective film inside and outside.
  • Page 17: Part 2 - Camera Connection

    Part 2 - Camera Connection Use the camera by connecting to DirectIP™ NVR or non DirectIP™ NVR, VMS such as IDIS Solution Suite Compact. With DirectIP™ NVR-based Layout Audio In Audio Out Alarm Out Power Sensor In Network Camera Monitor Out...
  • Page 18: With Non Directip™ Nvr-Based Layout

    Ideal for using the camera over the network from a remote location. The contents in the camera operation manual are only for users using the camera with non DirectIP™ NVR connection or VMS connection such as IDIS Solution Suite Compact.
  • Page 19: Part 3 - Appendix

    ID and password as a safety precaution. camera. Unable to launch IDIS Web. If the IDIS Web login screen is not loading, check which version of Microsoft Internet Explorer you are using. IDIS Web may not launch properly on versions 8.0 or below.
  • Page 20: Specifications

    Part 3 - Appendix Specifications These product specifications may change without prior notice. Video Image Sensor 1/2.8" CMOS Max. Resolution 3840 x 2160 Scanning Mode Progressive Scan Lens type Motorized Vari-focal Focal Length f=2.7-13.5mm Aperture F=1.8-F3.32 Iris Control DC Iris Angular Field of View Wide : 134.1°(D), 110.6°(H), 57.3°(V) Tele : 37.4°(D), 32.6°(H), 18.3°(V)
  • Page 21: Audio In/Out

    Part 3 - Appendix Audio In/Out Line-in 1ea / Line-out 1ea Alarm In 1 TTL, NC/NO Programmable, 4.3V(NC) or 0.3V(NO) threshold, 5V DC Alarm Out 1 TTL open collector, Max. load: 30mA, Max. voltage: 5VDC General Operating Temperature -40°C ~ +55°C (-104°F ~ +131°F) Boot Up Temperature -20°C ~ +55°C (-4°F ~ +131°F) Operating Humidity...
  • Page 22 IDIS Co., Ltd. For more information, please visit at www.idisglobal.com...

This manual is also suitable for:

Dc-d4831hrx

Table of Contents