Operating instructions

1. SAFETY REGULATIONS AND INFORMATION

Read these operating instructions carefully before starting work on the
device. Observe the following warnings to prevent malfunctions or
danger to persons.
These operating instructions are to be regarded as part of the device.
The device is only to be sold or passed on together with the operating
instructions.
These operating instructions may be duplicated and distributed to inform
about potential dangers and their prevention.
1

1.1 Hazard levels for warnings

1
1
These operating instructions use the following hazard levels to indicate
1
potentially hazardous situations and important safety regulations:
1
2
2
2
2
2
2
2
3
4
4
6
6
6
6
6

1.2 Staff qualifications

7
The device may only be transported, unpacked, installed, operated,
7
maintained and otherwise used by suitably qualified, trained and
7
authorized technical staff.
8
Only authorized specialists are permitted to install the device, to carry
9
out a test run and to perform work on the electrical installation.
10
10

1.3 Basic safety rules

10
The safety hazards associated with the device must be assessed again
10
following installation in the final product.
The locally applicable industrial safety regulations are always to be
10
observed when working on the device.
Keep the workplace clean and tidy. Untidiness in the work area
11
increases the risk of accidents.
11
Note the following when working on the device:
11
; Do not perform any modifications, additions or conversions on the
device without the approval of ebm-papst.

1.4 Voltage

; Check the device's electrical equipment at regular intervals; see
Chapter 6.2 Safety inspection.
; Replace loose connections and defective cables immediately.
DANGER
Indicates an imminently hazardous situation which will result in
death or serious injury if the specified actions are not taken.
Compliance with the instructions is imperative.
WARNING
Indicates a potentially hazardous situation which can result in
death or serious injury if the specified actions are not taken.
Exercise extreme caution while working.
CAUTION
Indicates a potentially hazardous situation which can result in
minor or moderate injury or damage to property if the specified
actions are not taken.
NOTE
A potentially harmful situation can occur and, if not avoided, can
lead to property damage.
DANGER
Electrically charged device
Risk of electric shock
→ When working on an electrically charged device, stand on a
rubber mat.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the R3G190-RB01-08 and is the answer not in the manual?

Questions and answers

Summary of Contents for ebm-papst R3G190-RB01-08

  • Page 1: Table Of Contents

    Note the following when working on the device: 6.3 Disposal ; Do not perform any modifications, additions or conversions on the device without the approval of ebm-papst. 1.4 Voltage ; Check the device's electrical equipment at regular intervals; see Chapter 6.2 Safety inspection.
  • Page 2: Safety And Protective Features

    Operating instructions R3G190-RB01-08 WARNING WARNING Live terminals and connections even with device Rotating device switched off Long hair and dangling items of clothing, jewelry and the like Electric shock can become entangled and be pulled into the device. Injuries can result.
  • Page 3: Intended Use

    Operating instructions R3G190-RB01-08 2. INTENDED USE The device is exclusively designed as a built-in device for conveying air according to its technical data. Any other usage above and beyond this does not conform with the intended purpose and constitutes misuse of the device.
  • Page 4: Technical Data

    Operating instructions R3G190-RB01-08 3. TECHNICAL DATA 3.1 Product drawing All dimensions in mm. Accessory part: Inlet ring 09576-2-4013, not included in scope of delivery Max. clearance for screw 5 mm Cable PVC AWG20, 1x 4-pole connector housing tyco 0-925075-0, 4x plug pin tyco 163555-6...
  • Page 5 Operating instructions R3G190-RB01-08 All dimensions in mm. Accessory part: inlet ring 09576-2-4013 not included in scope of delivery...
  • Page 6: Nominal Data

    Operating instructions R3G190-RB01-08 3.2 Nominal data Approval CSA C22.2 No. 77 + CAN/CSA- E60730-1; CCC; UL 1004-7 + 60730-1 Motor M3G055-BD ; Use the device in accordance with its degree of protection. Phase Information on surface quality Nominal voltage / VAC...
  • Page 7: Connection And Startup

    Operating instructions R3G190-RB01-08 4. CONNECTION AND STARTUP CAUTION Voltage The fan is a built-in component and has no disconnecting switch. 4.1 Mechanical connection → Only connect the fan to circuits that can be switched off with CAUTION an all-pole disconnection switch.
  • Page 8: Plug Connection

    Operating instructions R3G190-RB01-08 breakers (RCCB) with a trip threshold of 300 mA and delayed tripping (super-resistant, characteristic K). 4.2.4 Locked-rotor protection Due to the locked-rotor protection, the starting current (LRA) is equal to or less than the nominal current (FLA).
  • Page 9: Connection Diagram

    Operating instructions R3G190-RB01-08 4.4 Connection diagram Drawing preliminary! Conn. Designation Color Function/assignment CON 10 L black Power supply 230 VAC, 50 - 60 Hz, see nameplate for voltage range CON 11 N blue Neutral conductor CON 12 PE green/ Protective earth...
  • Page 10: Checking Connections

    Operating instructions R3G190-RB01-08 4.5 Checking connections 5. INTEGRATED PROTECTIVE FEATURES ; Ensure isolation from supply (all phases). The integrated protective functions cause the motor to switch off automatically in the event of the faults described in the table. ; Make sure a restart is impossible ;...
  • Page 11: Cleaning

    Visual inspection At least every Repair or cool down. protection 6 months replacement of cover for device In the event of further malfunctions, contact ebm-papst. intactness or damage Device for Visual inspection At least every Replacement of 6.1 Cleaning damage to...
  • Page 12 Miscellaneous insulators used in the terminal box ● Power cables ● Cables for internal wiring ● Electrolytic capacitors ● Dispose of electronic components employing the proper procedures for electronic scrap. → Please contact ebm-papst for any other questions on disposal.