Storage; Drain The Fuel - Yamaha EF2000iS - Inverter Generator Owner's Manual

Owners manual
Hide thumbs Also See for EF2000iS - Inverter Generator:
Table of Contents

Advertisement

1
1
1
1
AE00601

STORAGE

Long term storage of your machine will require some
preventive procedures to guard against deterioration.
AE01056

Drain the fuel

1. Turn the engine switch to "STOP" 1.
2. Remove the fuel tank cap. Extract the fuel from the
fuel tank into an approved gasoline container using
a commercially available handsiphon. Then, install
the fuel tank cap.
7DK-044
WARNING
Fuel is highly flammable and poisonous. Check
"SAFETY INFORMATION" (See page 1) carefully.
NOTICE
7DK-025
Immediately wipe off spilled fuel with a clean, dry,
soft cloth, since fuel may deteriorate painted sur-
faces or plastic parts.
3. Turn the engine switch to "ON" 1.
7DK-039
4. Turn the fuel tank cap air vent knob and fuel cock
knob to "ON" 1.
5. Start the engine and leave it run until it stops.
7DK-035
The engine stops in approx. 20 mins. time by run-
ning out of fuel.
TIP
9 Do not connect with any electrical devices.
(unloaded operation)
9 Duration of the running engine depends on the
amount of the fuel left in the tank.
7DK-038
– 30 –