Page 2
Record in the space below, the serial number found on the nameplate, located on the rear panel. Serial No. Date:...
Page 3
Solvent free products to improve Indoor Air Quality. Performance with Productivity The unique technology used in the formulation of the CFR chemical system make it the only line of carpet care chemicals that continue to perform under recycling. CFR chemical products have been specifically designed to enhance the performance of the patented CFR recycling system.
Page 5
Follow the 1, 2. 3. 4 order for safe SECOND , 4-stage CFR spot spotting and destaining! removal process to eliminate soils or stains 2. Pop-Out Designed to aggressively remove...
TABLE OF CONTENTS Unpacking your new Altra Series Cleaning Station ..........1 INTRODUCTION ....................2 SAFETY INSTRUCTIONS..................3 GROUNDING INSTRUCTIONS ................4 SET UP INSTRUCTION ..................4 Filter Installation ..................... 4 OPERATING INSTRUCTIONS................5 Performa......................5 Performa OZ without Ozone................5 Performa Elite....................
Page 8
PERFORMA Operator Manual Performa Elite Base Assembly....................44 Tank Assembly ....................46 Pump Motor Airline 400 HZ ................48 Pump Assembly....................50 Pressure Regulator..................52 Handle Assembly.................... 54 WIRING DIAGRAMS Perform 115 Volt..................... 56 Performa 230 Volt................... 57 Performa without Agitator ................58 Performa OZ 115 Volt..................
PERFORMA Operator Manual Congratulations on your purchase of a CFR Performa Series Cleaning Station. Read this entire manual before operating or servicing the Performa. Unpacking your new Performa Series Cleaning Station The Performa Series Cleaning Station was thoroughly inspected, tested, and packaged to deliver the equipment in good operating condition.
Standard CFR hoses and tools can be connected to the Performa for difficult spots and stains, upholstery, wall panels, and other detailed work. The Performa Series comes in three models: the Performa, the Performa Elite and the Performa...
PERFORMA Operator Manual IMPORTANT SAFETY INSTRUCTIONS The Performa Series is intended for use only as described in this manual with recommended attachments and chemicals. Using the Performa in any manner not described in this manual can void the warranty. Use only manufacturer’s recommended accessories.
Do not modify the plug provided with the appliance – if it will not fit the outlet; have a grounded outlet installed by a qualified electrician. SET UP INSTRUCTION 1. Fill out Warranty Card and return it to CFR. Filter Installation Inlet Basket Install inlet basket assembly into the tank opening.
PERFORMA Operator Manual OPERATING INSTRUCTIONS Performa, Performa OZ (without Ozone) and Performa Elite Check to make sure pump strainers and recycling filters are securely in place. The recycling filter (cage and filter) must be securely seated on the tank bottom. To properly seat the recycling filter, rotate the filter 1/8 turn while pushing down on the filter assembly.
Page 14
EXCESSIVE FOAM TANK IN THE TANK MAY CAUSE VACUUM MOTOR FLOODING AND EQUIPMENT DAMAGE. If excessive foam is noticed in the tank pour 2 ounces of CFR Defoam directly into the tank or into the vacuum hose while the vacuum is running.
EXCESSIVE FOAM TANK IN THE TANK MAY CAUSE VACUUM MOTOR FLOODING AND EQUIPMENT DAMAGE. If excessive foam is noticed in the tank pour 1 ounce of CFR Defoam directly into the tank or into the vacuum hose while the vacuum is running.
PERFORMA Operator Manual TOOL USAGE Hose Assembly Attach hose assembly to machine by attaching vacuum hose to the tank cover and the fluid hose to the quick coupler on the front of the machine.Mote: You will have to disconnect the fluid line that goes to the spray header to allow for installation of the accessory hose.
Remove the filter and rinse with water. Remove any debris from the strainer. Keep o-ring and threads of the plug lubricated. CFR DeFoam is a good lubricant or use a non-petroleum based lubricant. This will ensure a tighter seal.
A convenient method is to insert the nozzle into a garden hose ball valve, tighten the ball valve to a faucet, and turn on the water. (CFR has ball valves available, part #7AX020). Inspect nozzle and repeat cleaning procedure, if necessary.
Check fluid level – must have at least 4 gallons in tank. • Water dripping from bottom Check machine for excess foaming. Add CFR Defoam to tool hose of machine exhaust. and tank. Open machine top cover and let vacuum run for 10 minutes to dry out vacuum motor, then close lid and resume cleaning.
Page 20
Check CFR chemical usage instructions for proper application. • Multiple cleanings may be needed to clean deeply imbedded dirt that is pulled to the surface by CFR’s deep cleaning technology. Offset cleaning passes by 6 inches. • No fluid from cleaning head Check that prime switch is in off position.
PERFORMA Operator Manual SPECIFICATIONS – Performa One 50’ (15.24m) cord, 14 ga, 3 wire, molded end plug Power Cord 115 volts AC, 60 Hz – 230 Volts AC, 50 Hz Voltage 15 amps with brush/ 13.8 without brush Amps Volume 8 gallons (30.28 liters) Tank Fill to red indicator line on recycling filter Fill Level...
PERFORMA Operator Manual SPECIFICATIONS – Performa OZ One 50’ (15.24m) cord, 14 ga, 3 wire, molded end plug Power Cord 115 volts AC, 60 Hz Voltage 15 amps with ozone/ 14 amps without ozone Amps Volume 8 gallons (30.28 liters) Tank Fill to red indicator line on recycling filter Fill Level...
PERFORMA Operator Manual SPECIFICATIONS – Performa OZ 230 Volts One 50’ (15.24m) cord, 14 ga, 3 wire, molded end plug Power Cord 115 volts AC, 60 Hz Voltage 8 amps with ozone/ 7.5 amps without ozone Amps Volume 8 gallons (30.28 liters) Tank Fill to red indicator line on recycling filter Fill Level...
PERFORMA Operator Manual SPECIFICATIONS – Performa Elite 115 V 60 HZ One 50’ (15.24m) cord, 14 ga, 3 wire, molded end plug Power Cord 115 volts AC, 60 Hz Voltage 14 amps Amps Volume 8 gallons (30.28 liters) Tank Rotationally molded polyethylene (LLPE) Fill to red indicator line on recycling filter Fill Level 3 stage with 135 inches of water lift...
PERFORMA Operator Manual SPECIFICATIONS – Performa Elite 115 V 400 HZ One 50’ (15.24m) cord, 14 ga, 3 wire, molded end plug Power Cord 115 volts AC, 400 Hz Voltage 14 amps Amps Volume 8 gallons (30.28 liters) Tank Rotationally molded polyethylene (LLPE) Fill to red indicator line on recycling filter Fill Level 3 stage with 135 inches of water lift...
PERFORMA Operator Manual Performa (115V & 230V) Pressure Regulator Assembly 72045A Part # Description Regulator Body O-Ring Seat Quad Ring Piston Thrust Plate Spring Handle Item #’s 2,3,4,5 are contained in the Rebuild Kit #10370A...
PERFORMA Operator Manual Performa OZ Pressure Regulator Assembly 72045A Part # Description Regulator Body O-Ring Seat Quad Ring Piston Thrust Plate Spring Handle Item #’s 2,3,4,5 are contained in the Rebuild Kit #10370A...
PERFORMA Operator Manual Performa Elite Pressure Regulator Assembly 72045A Part # Description Regulator Body O-Ring Seat Quad Ring Piston Thrust Plate Spring Handle Item #’s 2,3,4,5 are contained in the Rebuild Kit #10370A...
CFR, a Tacony company, warrants new products manufactured and sold under the name CFR to be free from defects in materials and workmanship under normal use and service. CFR’s obligation under this warranty is limited to repairing or replacing, at our...
Page 74
PERFORMA Operator Manual For more information about top quality CFR products please see your local CFR distributor or visit us at www.CFRcorp.com Thank you for purchasing CFR Environmental Cleaning Systems. CFR Environmental Cleaning Systems 3101 Wichita Court Fort Worth, Texas 76140 817.551.0700...
Need help?
Do you have a question about the PERFORMA Series and is the answer not in the manual?
Questions and answers