  • Page 1 Installation manual Washer — Super Dry WSD780 Compass Pro Type EXSM.X. 438917626/US 2025.02.12 Wascomat Commercial Laundry Equipment 516-371-4400 www.wascomat.com...
  • Page 2: Tech Support

    WARRANTY CLAIMS Wascomat’s Technical Support Staff will honor valid manufacturer’s parts warranty claims providing your Wascomat machines are registered for warranty coverage upon installation. If they are not registered, you can validate your warranty claim by providing information about when and where you purchased the Wascomat machine(s), the model and serial number(s).
  • Page 3 Safety WARNING: ALL OPERATING AND MAINTENANCE PROCEDURES SHOWN ON THE NEXT PAGE OF THIS MANUAL MUST BE FOLLOWED DAILY FOR PROPER OPERATION OF YOUR MACHINE. MAKE CERTAIN TO KEEP THIS MANUAL IN A SECURE PLACE FOR FUTURE REFERENCE. PLEASE ENTER THE FOLLOWING INFORMATION AS IT APPEARS ON THE MACHINE(S) DATA PLATE(S).
  • Page 4: Important Safety Instructions

    Safety IMPORTANT SAFETY INSTRUCTIONS WARNING - To reduce the risk of fire, electric shock, or injury to persons when using your appliance, including the following: 1. Read all instructions before using the appliance. 2. This machine must be securely bolted to an uncovered concrete floor. 3.
  • Page 5 Safety NOTICE TO: OWNERS, OPERATORS AND DEALERS IMPROPER INSTALLATION AND INADEQUATE MAINTENANCE, POOR HOUSEKEEPING AND WILLFUL NEGLECT OR BYPASSING OF SAFETY DEVICES MAY RESULT IN SERIOUS ACCIDENTS OR INJURY. TO ASSURE THE SAFETY OF CUSTOMERS AND/OR OPERATORS OF YOUR MACHINE, THE FOLLOWING MAINTENANCE CHECKS MUST BE PERFORMED ON A DAILY BASIS. Prior to operation of the machine, check to make certain that all operating instructions and warning signs are affixed to the machine and legible.
  • Page 6: Notice To Installer

    Improper fastening of this machine to its foundation, inferior foundation materials, an undersized foundation, the use of fabricated steel bases not provided by Wascomat or its approved supplier(s), the use of an improper type, number, or size of mounting bolts, or failure to use proper hardware on mounting bolts may result in damage to the machine that will not be covered by the manufacturer's warranty.
  • Page 7: Table Of Contents

    Contents Contents 1 Safety Precautions ..........................9 General safety information......................9 Commercial use only........................9 Copyright ..........................9 Symbols..........................10 2 Technical data........................... 11 Drawing ..........................11 Technical data .........................12 Connections ..........................12 3 Setup ...............................13 Unpacking ..........................13 Recycling instruction for packaging ...................14 Siting ............................15 Mechanical installation ......................16 3.4.1 Foundation requirement....................16 3.4.2 Measurements for foundation ..................16 3.4.3 Casting a plinth ......................17...
  • Page 9: Safety Precautions

    The machine/machines covered by this manual is/are made for commercial and industrial use only. 1.3 Copyright This manual is intended solely for consultation by the operator and can only be given to third parties with the permis- sion of Wascomat company.
  • Page 10: Symbols

    Installation manual 1.4 Symbols Caution Caution, high voltage Read the instructions before using the machine...
  • Page 11: Technical Data

    Installation manual 2 Technical data 2.1 Drawing B(a) B(b) fig.X02368 Operating panel Door opening, ⌀ 535 mm / ⌀ 21 1/16 inch Detergent container Cold/Hot water (Detergent container) Cold water Hot water Cold/Hot water or Re-used water with network pressure (option) Drain valve Liquid detergent supply Electrical connection...
  • Page 12: Technical Data

    Installation manual 2.2 Technical data Weight, net 1234 Drum volume litres 12.4 Drum diameter inch 36 1/4 Drum speed during wash Drum speed during extraction G-factor, max. Heating: Electricity Heating: Steam Heating: Hot water Frequency of the dynamic force 10.8 Floor load at max extraction 6.9±10.7 lbs force...
  • Page 13: Setup

    Installation manual 3 Setup 3.1 Unpacking Note! Two persons are recommended for the unpacking. Remove the bolts between the machine and pallet. There are two bolts in the front of the machine and two bolts in the back of the machine. fig.7675 Remove the machine from the pallet.
  • Page 14: Recycling Instruction For Packaging

    Installation manual 3.2 Recycling instruction for packaging fig.X02395 Fig. Description Code Type Wrapping film LDPE 4 Plastics Corner protection PS 6 Plastics Cardboard packaging PAP 20 Paper Pallet FOR 50 Wood Screw FE 40 Steel FE 40 Steel Plastic bag PET 1 Plastics...
  • Page 15: Siting

    Installation manual 3.3 Siting Install the machine close to a floor drain or open drain. The machine should be positioned so that there is plenty of room for working, both for the user and service personnel. The figure shows minimum distance to a wall and/or other machines. fig.X00959 50 mm / 1 15/16 inch 400 mm / 15 3/4 inch...
  • Page 16: Mechanical Installation

    Installation manual 3.4 Mechanical installation 3.4.1 Foundation requirement In this type of machine, the drum is attached directly to the frame. As a result the floor under the machine must be stable enough to absorb the dynamic forces generated during spin cycles. For that reason, the mounting bolts must be cast into the floor material itself.
  • Page 17: Casting A Plinth

    Installation manual 3.4.3 Casting a plinth A plinth should be used where the existing floor is less than 200 mm / 7 7/8 inch thick or in order to ensure that the machine is above the level of any water leakages. The plinth should be approximately 150 - 200 mm / 5 7/8 —...
  • Page 18: Chemical Bolts / Chemical Anchors

    Installation manual 3.4.4 Chemical bolts / chemical anchors 3.4.5 Fastening the machine Place wide steel shims (A) on the concrete foundation over the bolts. fig.7666 Position the machine on the foundation. Check that the machine is in level and stand firmly on all supporting points. Spacing washers must be mounted if one or more of these points is not resting against the foundation.
  • Page 19 Installation manual Tighten the 10 nuts. Check and tighten the nuts every week for the first month. Final tightening torque as recommended spec is M16 (5/8 inch) = 150 Nm / 110.6 lb-ft. fig.7670 It is of the upmost importance that the machine is placed in level, from side to side as well as front to rear. Check that the machine is in level and tighten all nuts every week for the first month.
  • Page 20: Water Connection

    Installation manual 4 Water connection All water intake connections to the machine should be fitted with manual shut-off valves and filters, to facilitate instal- lation and servicing. In certain cases non-return valves will need to be fitted before the machine to comply with local plumbing regulations.
  • Page 21: Connection Of External Dosing Systems

    Installation manual 5 Connection of external dosing systems 5.1 Connection of the hoses The machine is prepared for connection of external dosing systems or water re-use systems etc. The connections are closed at delivery. Open any of the connections that shall be used by drilling a hole where the hoses shall be connected.
  • Page 22: Machine Without Connectors

    Installation manual 5.2.1 Machine without connectors Connect the external dosing system to the I/O board, which is located to the right of the incoming power supply. The I/O board has edge connectors for connecting external dosing systems. Edge connectors on the I/O board can be loosened for connecting cables. fig.6572 11 = N 18 = Program run...
  • Page 23: Outputs

    Installation manual 5.2.2 Outputs Connect the power supply (e.g. 24V DC) for the external liquid supplies to 9 and 10. If an internal power supply (from the machine) is being used, it can be taken from 1 (N) and connected to 9 and from 2 (L) and connected to 10. Max load on the outputs 0.5 A.
  • Page 24: Inputs

    Installation manual 5.2.3 Inputs The signal level can be 5-24V DC/AC or 100- 240V AC. For 5-24V, the signal reference is connected to 3 and for 100-240V to 4. Potentials on the inputs cannot be mixed. Note! The I/O board will be damaged if the voltage on connection 3 is too high > 24V. Connection 8 may be connected if the program is to pause, e.g.
  • Page 25: Drain Connection

    Installation manual 6 Drain connection Connect a 75 mm / 3 inch flexible hose to the drain outlet of the machine. The drain hose must not have any sharp bends and must slope from the machine to assure proper drainage. The outlet must open freely to the main drains. Note! Do not reduce the size of the drain connection from the machine to the main drain.
  • Page 26: Electrical Connection

    Installation manual 7 Electrical connection 7.1 Electrical installation The electrical installation may only be carried out by qualified personnel. Machines with frequency-controlled motors can be incompatible with certain types of earth leakage circuit break- er. It is important to know that the machines are designed to provide a high level of personal safety, which is why items of external equipment such as earth leakage circuit breakers are not necessary but is recommended.
  • Page 27: Machine Connection

    Installation manual 7.3 Machine connection 7.3.1 Single-phase connection Connect the earth and other two wires as shown. 1NAC L1 L2...
  • Page 28: Three-Phase Connection

    Installation manual 7.3.2 Three-phase connection Connect the earth, neutral and phase wires as shown. L1 L2 L3 3N AC 3N AC...
  • Page 29: Functions For I/O-Cards

    Installation manual 7.4 Functions for I/O-cards The electrical schematic can be one of the following: 7.4.1 External coin meter/Central payment (2A) The signal received from external coin meters must be a pulse between 300–3000 ms (500 ms is recommended) with a minimum pause of 300 ms (500 ms is recommended) between two pulses. fig.6606A...
  • Page 30: Central Payment (2B)

    Installation manual 7.4.2 Central payment (2B) To start the machine from a central payment system, the payment system must transmit a start pulse to the machine. The start pulse can be either 230V or 24V. In order to receive a feedback signal once the machine has started, 230V or 24V must be connected to connection 19.
  • Page 31: Outputs For Detergent Signals And Inputs For Pause Signals, "Empty" Signal And Price Reduction (2D)

    Installation manual 7.4.3 Outputs for detergent signals and inputs for pause signals, "empty" signal and price reduction (2D) The figure shows standard function addressing for machines with the coin program package. By maintaining an active (high) signal on connection 5 ("Price red"), the price of the program can be reduced. This function has a number of uses, including providing reductions during a specific period of the day.
  • Page 32: Machines With I/O Module Type 3

    Installation manual 7.4.4 Machines with I/O module type 3 By maintaining an active (high) signal on connection 3 "Price reduction”, the price of the program can be reduced. This function has a number of uses, including providing reductions during a specific period of the day. Whilst the sig- nal remains active (high), the price of the program is reduced by the percentage entered in the price programming menu.
  • Page 33: Steam Connection

    Installation manual 8 Steam connection Inlet pipes connected to the machine must be equipped with a manual shut-off valve to facilitate installation and servicing. Attach the filter supplied with the machine to the manual shut-off valve. Connection hoses should be of the quality required according to regulations in the country of use. Connection size at filter: DN 15 (BSP 1/2").
  • Page 34: At First Power Up

    Installation manual 9 At first power up When the installation is complete and the power is connected for the first time you will be forced to make the following settings. When one setting is ready you will automatically enter the next one. •...
  • Page 35: Function Check

    Installation manual 10 Function check May only be carried out by qualified personnel. A function check must be made when the installation is finished and before the machine can be ready to be used. Open the manual water valves. Start a program. •...
  • Page 36: Disposal Information

    Installation manual 11 Disposal information 11.1 Disposal of appliance at end of life Before disposing of the machine, make sure to carefully check its physical condition, and in particular any parts of the structure that can give or break during scrapping. The machine’s parts must be disposed of in a differentiated way, according to their different characteristics (e.g.
  • Page 38 www.wascomat.com...