Channel Controls - Yamaha 01V96i Reference Manual

Reference manual
Hide thumbs Also See for 01V96i:
Table of Contents

Advertisement

96
Remote Control
Assigning MIDI Messages to

Channel Controls

You can quickly use the MIDI Remote function if you use the
factory presets in the banks. However, you can also assign the
desired MIDI messages to the faders or [ON] buttons.
This section describes how to assign MIDI messages to the
channel controls, using the example of assigning Hold
On/Off messages (Control Change #64; Values 127 & 0) to the
Channel 1 [ON] button.
1.
Connect the 01V96i's MIDI IN port to the
MIDI OUT port of a MIDI keyboard to which
a Hold On/Off controllable foot switch is con-
nected. Enable the MIDI Remote function on
the 01V96i.
MIDI OUT
MIDI IN
CH1-4
CH5-8
1
2
3
4
5
6
7
8
9
10
11
12
PHANTOM +48V
13
15
A
A
A
A
A
A
A
A
A
A
A
A
14
16
B
B
B
B
B
B
B
B
B
B
B
B
IN
OUT
INPUT
(BAL)
2TR
-10dBV
(UNBAL)
INSERT
OUT IN
(UNBAL)
CH15/16
MONITOR
2TR IN
2TR IN
INSERT I/O
INSERT I/O
INSERT I/O
INSERT I/O
INSERT I/O
INSERT I/O
INSERT I/O
INSERT I/O
INSERT I/O
INSERT I/O
INSERT I/O
INSERT I/O
PAD
20dB
20dB
20dB
20dB
20dB
20dB
20dB
20dB
20dB
20dB
20dB
20dB
+4
-26
+4
-26
0
GAIN
GAIN
LEVEL
MONITOR
OUT
-16
-60
-16
-60
-16
-60
-16
-60
-16
-60
-16
-60
-16
-60
-16
-60
-16
-60
-16
-60
-16
-60
-16
-60
+4
-26
+4
-26
GAIN
GAIN
GAIN
GAIN
GAIN
GAIN
GAIN
GAIN
GAIN
GAIN
GAIN
GAIN
GAIN
GAIN
PEAK
PEAK
PEAK
PEAK
PEAK
PEAK
PEAK
PEAK
PEAK
PEAK
PEAK
PEAK
PEAK
PEAK
13
14 15
16
SIGNAL
SIGNAL
SIGNAL
SIGNAL
SIGNAL
SIGNAL
SIGNAL
SIGNAL
SIGNAL
SIGNAL
SIGNAL
SIGNAL
SIGNAL
SIGNAL
DISPLAY ACCESS
SCENE MEMORY
SCENE
DIO/SETUP
MIDI
UTILITY
STORE
RECALL
SOLO
OVER
/ INSERT/
PAN/
PAIR/
PATCH
DELAY
ROUTING
GROUP
0
-3
-6
DEC
INC
-9
DYNAMICS
EQ
EFFECT
VIEW
-12
FADER MODE
-15
-18
-24
-30
AUX
1
AUX
2
AUX
3
AUX
4
-36
HIGH
Q
-48
STEREO
AUX
5
AUX
6
AUX
7
AUX
8
HIGH-MID
FREQUENCY
HOME (METER)
LOW-MID
LAYER
ENTER
LOW
1-16
17-32
MASTER REMOTE
GAIN
ST IN
SEL
SEL
SEL
SEL
SEL
SEL
SEL
SEL
SEL
SEL
SEL
SEL
SEL
SEL
SEL
SEL
SEL
SEL
SOLO
SOLO
SOLO
SOLO
SOLO
SOLO
SOLO
SOLO
SOLO
SOLO
SOLO
SOLO
SOLO
SOLO
SOLO
SOLO
SOLO
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
ST IN 1
+10
0
+10
0
+10
0
+10
0
+10
0
+10
0
+10
0
+10
0
+10
0
+10
0
+10
0
+10
0
+10
0
+10
0
+10
0
+10
0
0
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
USER DEFINED
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
15
30
15
30
15
30
15
30
15
30
15
30
15
30
15
30
15
30
15
30
15
30
15
30
15
30
15
30
15
30
15
30
30
20
40
20
40
20
40
20
40
20
40
20
40
20
40
20
40
20
40
20
40
20
40
20
40
20
40
20
40
20
40
20
40
40
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
40
60
40
60
40
60
40
60
40
60
40
60
40
60
40
60
40
60
40
60
40
60
40
60
40
60
40
60
40
60
40
60
60
70
70
70
70
70
70
70
70
70
70
70
70
70
70
70
70
70
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
8
9
10
11
12
13
14
15
16
1
2
3
4
5
6
7
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
STEREO
AUX
1
AUX
2
AUX
3
AUX
4
AUX
5
AUX
6
AUX
7
AUX
8
BUS
1
BUS
2
BUS
3
BUS
4
BUS
5
BUS
6
BUS
7
BUS
8
2.
Press the DISPLAY ACCESS [DIO/SETUP] but-
ton repeatedly until the DIO/Setup | Remote
page appears, then set the TARGET parame-
ter to USER DEFINED.
You can now use the MIDI Remote function. Refer to the
previous section for more information on using the MIDI
Remote function.
3.
Move the cursor to the desired bank button
(BANK parameter buttons 1–4), then press
[ENTER].
4.
Press the [SEL] buttons for the desired chan-
nels.
Currently-assigned MIDI messages appear in the ON and
FADER sections.
Tip: You can also choose the desired channels using the ID,
SHORT, and LONG parameters.
01V96i—Reference Manual
MIDI OUT
MIDI IN
MIDI keyboard
CH9-12
L
R
PHONES
10
0
10
LEVEL
PHONES
CLEAR
Foot switch
SEL
SOLO
ON
ST IN 2
KEYS
1
2
3
4
5
6
7
8
5.
Move the cursor to the LEARN button in the
ON section, then press [ENTER].
MIDI messages received at the MIDI IN port of the
01V96i will be assigned to the DATA parameter boxes in
the ON section.
6.
Press and hold down the MIDI keyboard foot
switch.
The MIDI Hold On message is assigned in the DATA
parameter box.
MIDI messages are described below:
• 00–7F
MIDI messages are expressed in hexadecimal.
• END
This message indicates the end of MIDI messages. Subse-
quent messages assigned in the DATA parameter boxes
will be ignored.
• –
This message indicates that no messages are assigned to
the DATA parameter boxes.
Tip: When you click the LEARN button to assign MIDI mes-
sages, the 01V96i automatically recognizes the end of the
messages and assigns END and "–. "
7.
While continuing to hold down the foot
switch, turn off the LEARN button.
8.
Move the cursor to the third parameter box
("7F" in this example), then rotate the Param-
eter wheel to change the value to SW.
"SW" is a variable that changes depending on the [ON]
button's on/off status. You can use the following variables
in MIDI messages.
• SW
This variable is selectable only in the DATA parameter
boxes of the ON section. When the [ON] buttons are
turned on, "7F" (127 in decimal) is output. When the
[ON] buttons are turned off, "00" (0 in decimal) is output.
• FAD
This variable is selectable only in the DATA parameter
boxes of the FADER section. When you operate the fad-
ers, continuously changing values in the range of 00 to 7F
(0–127 in decimal) are output.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents