Advanced combustion technology wood insert installation and operation (28 pages)
Summary of Contents for Quadra-Fire 43M-ACC-C
Page 1
Hearth and Home Technologies Project # 19-538 Brand: Quadra Fire Model: 43M-ACC-C Additional Models: 43ST-ACC-C, Discovery-III-C, FF-WP-300 Type: Residential Non-catalytic Wood Fired Heater December 19, 2019 Revised Date: February 12, 2025 EPA Test Method 28R for Certification and Auditing of Wood...
Project # 19-538 Model: 43M-ACC-C Revision Summary Date: December 19, 2019 – Original Issue Date: August 5, 2024– The manufacturer changed a k-list component (fuel loading door) and added an additional model name. The new fuel loading door has been reviewed and determined to be only aesthetic changes (door frame shape is now square), glass and gaskets are equivalent to the original door.
Affidavit PFS-TECO was contracted by Hearth & Home Technologies (HHT) to provide testing services for the 43M-ACC-C Non-Catalytic Wood-Fired Room Heater per EPA Method 28R, Certification and Auditing of Wood Heaters. All testing and associated procedures were conducted at HHT’s Colville, WA laboratory beginning on 12/3/2019 and ending on 12/6/2019.
Model: 43M-ACC-C Introduction Hearth and Home Technologies of Halifax, PA, contracted with PFS-TECO to perform EPA certification testing on 43M-ACC-C Non-Catalytic Wood-Fired Room Heater. All testing was performed at HHT’s Colville, WA laboratory. Testing was performed by Mr. Aaron Kravitz.
Project # 19-538 Model: 43M-ACC-C Test Procedures and Equipment All Sampling and analytical procedures were performed by Aaron Kravitz. procedures used are directly from ASTM E2780 and ASTM E2515. See the list below for equipment used. See Appendix C submitted with this report for calibration data.
Model: 43M-ACC-C Results A total of 5 test runs were performed on the 43M-ACC-C. Run #5, a fan confirmation test, was not used in any weighted average results calculations. The weighted average emissions rate for the 4 run test series was measured to be 1.6 g/hr with a Higher Heating Value efficiency of 74.2%.
Project # 19-538 Model: 43M-ACC-C Test Run Narrative Run 1 Run 1 was performed on 12/3/2019 as a category 2 test, per EPA Method 28R. The total test time was 359 minutes. The particulate emissions rate for the test was 1.65 g/hr, the burn rate was 0.95 kg/hr with an HHV efficiency of 75.1%.
Page 11
Project # 19-538 Model: 43M-ACC-C Samples were observed to have negative catch weights for all 5 runs, and these catch values were corrected to zero in the results reported above. If these negative weights are left uncorrected, the results are as follows:...
Project # 19-538 Model: 43M-ACC-C Test Conditions Summary Testing conditions for all runs fell within allowable specifications of ASTM E2780 and ASTM E2515. A summary of facility conditions, fuel burned, and run times is listed below. Average Preburn Ambient (°F)
Model: 43M-ACC-C Appliance Description Model(s): 43M-ACC-C Additional Models Discussion: In addition to the 43M-ACC-C, the manufacturer also offers the models 43ST-ACC-C and Discovery-III-C, which are identical in firebox construction and air intake/control. The difference between the 43M and 43ST models is that the 43ST has a stepped top, which does not affect flue gas passageways or firebox volume.
Project # 19-538 Model: 43M-ACC-C Test Fuel Properties Test fuel used was dimensional Doug fir lumber, air-dried to the specified moisture content range. Typical fuel loads are pictured below: Typical Test Fuel Load Configuration Typical Test Fuel Loaded in Test Stove...
Project # 19-538 Model: 43M-ACC-C Sampling Locations and Descriptions Sample ports are located 16.5 feet downstream from any disturbances and 1 foot upstream from any disturbances. Flow rate traverse data was collected 12 feet downstream from any disturbances and 5.5 feet upstream from any disturbances. (See below).
Project # 19-538 Model: 43M-ACC-C Sampling Methods ASTM E2515 was used in collecting particulate samples. The dilution tunnel is 6 inches in diameter. All sampling conditions per ASTM E2515 were followed. No alternate procedures were used, and no sampling intervals fell outside of proportional rates of +/- 10%.
Project # 19-538 Model: 43M-ACC-C List of Appendices The following appendices have been submitted electronically in conjunction with this report: Appendix A – Test Run Data, Technician Notes, Sample Analysis, and Photos Appendix B – Labels and Manuals Appendix C –Equipment Calibration Records Appendix D –...
Page 22
WOOD STOVE TEST DATA PACKET ASTM E2780/E2515 Run 1 Data Summary Client: Hearth and Home Model: 4300ACC-C Job #: 19-538 Tracking #: 0050 Test Date: 12/3/2019 12/18/2019 Techician Signature Date PFS-TECO Page 1 of 39...
Page 23
Run 1 Emissions TEST RESULTS - ASTM E2780 / ASTM E2515 Client: Hearth and Home Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/3/2019 0.95 Burn Rate (kg/hr): Ambient Sample Sample 1st Hour Filter Sample Train A Train B Total Sample Volume (ft 0.000...
Page 24
Run 1 Emissions B415.1 Efficiency Results Manufacturer: Hearth and Home Model: 4300ACC-C Date: 12/03/19 Run: Control #: 19-538 Test Duration: Output Category: Test Results in Accordance with CSA B415.1-09 HHV Basis LHV Basis Overall Efficiency 75.1% 81.1% Combustion Efficiency 91.9% 91.9% Heat Transfer Efficiency 81.6%...
Page 25
Run 1 Emissions WOODSTOVE FUEL DATA - ASTM E2780 Client: Hearth and Home Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/3/2019 Preburn Fuel Information Moisture Moisture Size Length (in) Content Size Length (in) Content (% DB) (% DB) 8.00 19.9...
Page 26
Run 1 Emissions DILUTION TUNNEL & MISC. DATA - ASTM E2780 / E2515 Client: Hearth and Home Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Test Start Time: 11:25 Date: 12/3/2019 Total Sampling Time (min): Pre-Test Post Test Avg.
Page 27
Run 1 Emissions WOODSTOVE PREBURN DATA - ASTM E2780 Client: Hearth and Home Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/3/2019 Recording Interval (min): Run Time (min): Temperatures (°F) Elapsed Scale Stove Flue Draft Time Reading FB Left FB Right FB Back...
Page 28
Run 1 Emissions WOODSTOVE PREBURN DATA - ASTM E2780 Client: Hearth and Home Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/3/2019 Recording Interval (min): Run Time (min): Temperatures (°F) Elapsed Scale Stove Flue Draft Time Reading FB Left FB Right FB Back...
Page 29
Run 1 Emissions WOODSTOVE PREBURN DATA - ASTM E2780 Client: Hearth and Home Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/3/2019 Recording Interval (min): Run Time (min): Temperatures (°F) Elapsed Scale Stove Flue Draft Time Reading FB Left FB Right FB Back...
Page 30
Run 1 Emissions BOX A TEST DATA - ASTM E2780 / ASTM E2515 Client: Hearth and Home Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/3/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Elapsed Dilution Orifice Meter...
Page 31
Run 1 Emissions BOX A TEST DATA - ASTM E2780 / ASTM E2515 Client: Hearth and Home Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/3/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Elapsed Dilution Orifice Meter...
Page 32
Run 1 Emissions BOX A TEST DATA - ASTM E2780 / ASTM E2515 Client: Hearth and Home Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/3/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Elapsed Dilution Orifice Meter...
Page 33
Run 1 Emissions BOX A TEST DATA - ASTM E2780 / ASTM E2515 Client: Hearth and Home Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/3/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Elapsed Dilution Orifice Meter...
Page 34
Run 1 Emissions BOX A TEST DATA - ASTM E2780 / ASTM E2515 Client: Hearth and Home Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/3/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Elapsed Dilution Orifice Meter...
Page 35
Run 1 Emissions BOX A TEST DATA - ASTM E2780 / ASTM E2515 Client: Hearth and Home Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/3/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Elapsed Dilution Orifice Meter...
Page 36
Run 1 Emissions BOX A TEST DATA - ASTM E2780 / ASTM E2515 Client: Hearth and Home Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/3/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Elapsed Dilution Orifice Meter...
Page 37
Run 1 Emissions BOX A TEST DATA - ASTM E2780 / ASTM E2515 Client: Hearth and Home Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/3/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Elapsed Dilution Orifice Meter...
Page 38
Run 1 Emissions BOX A TEST DATA - ASTM E2780 / ASTM E2515 Client: Hearth and Home Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/3/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Elapsed Dilution Orifice Meter...
Page 39
Run 1 Emissions BOX A TEST DATA - ASTM E2780 / ASTM E2515 Client: Hearth and Home Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/3/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Elapsed Dilution Orifice Meter...
Page 40
Run 1 Emissions BOX A TEST DATA - ASTM E2780 / ASTM E2515 Client: Hearth and Home Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/3/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Elapsed Dilution Orifice Meter...
Page 41
Run 1 Emissions BOX B TEST DATA - ASTM E2780 / ASTM E2515 Client: Hearth and Home Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/3/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample...
Page 42
Run 1 Emissions BOX B TEST DATA - ASTM E2780 / ASTM E2515 Client: Hearth and Home Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/3/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample...
Page 43
Run 1 Emissions BOX B TEST DATA - ASTM E2780 / ASTM E2515 Client: Hearth and Home Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/3/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample...
Page 44
Run 1 Emissions BOX B TEST DATA - ASTM E2780 / ASTM E2515 Client: Hearth and Home Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/3/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample...
Page 45
Run 1 Emissions BOX B TEST DATA - ASTM E2780 / ASTM E2515 Client: Hearth and Home Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/3/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample...
Page 46
Run 1 Emissions BOX B TEST DATA - ASTM E2780 / ASTM E2515 Client: Hearth and Home Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/3/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample...
Page 47
Run 1 Emissions BOX B TEST DATA - ASTM E2780 / ASTM E2515 Client: Hearth and Home Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/3/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample...
Page 48
Run 1 Emissions BOX B TEST DATA - ASTM E2780 / ASTM E2515 Client: Hearth and Home Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/3/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample...
Page 49
Run 1 Emissions BOX B TEST DATA - ASTM E2780 / ASTM E2515 Client: Hearth and Home Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/3/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample...
Page 50
Run 1 Emissions BOX B TEST DATA - ASTM E2780 / ASTM E2515 Client: Hearth and Home Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/3/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample...
Page 51
Run 1 Emissions BOX B TEST DATA - ASTM E2780 / ASTM E2515 Client: Hearth and Home Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/3/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample...
Page 52
Run 1 Emissions WOODSTOVE SURFACE TEMPERATURE DATA Client: Hearth and Home Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/3/2019 Stove Δ Temperature Data (°F) Stove Surface Elapsed Time (min) FB Left FB Right FB Back FB Top FB Bottom Catalyst Exit...
Page 53
Run 1 Emissions WOODSTOVE SURFACE TEMPERATURE DATA Client: Hearth and Home Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/3/2019 Stove Δ Temperature Data (°F) Stove Surface Elapsed Time (min) FB Left FB Right FB Back FB Top FB Bottom Catalyst Exit...
Page 54
Run 1 Emissions WOODSTOVE SURFACE TEMPERATURE DATA Client: Hearth and Home Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/3/2019 Stove Δ Temperature Data (°F) Stove Surface Elapsed Time (min) FB Left FB Right FB Back FB Top FB Bottom Catalyst Exit...
Page 55
Run 1 Emissions WOODSTOVE SURFACE TEMPERATURE DATA Client: Hearth and Home Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/3/2019 Stove Δ Temperature Data (°F) Stove Surface Elapsed Time (min) FB Left FB Right FB Back FB Top FB Bottom Catalyst Exit...
Page 56
Run 1 Emissions WOODSTOVE SURFACE TEMPERATURE DATA Client: Hearth and Home Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/3/2019 Stove Δ Temperature Data (°F) Stove Surface Elapsed Time (min) FB Left FB Right FB Back FB Top FB Bottom Catalyst Exit...
Page 57
Run 1 Emissions WOODSTOVE SURFACE TEMPERATURE DATA Client: Hearth and Home Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/3/2019 Stove Δ Temperature Data (°F) Stove Surface Elapsed Time (min) FB Left FB Right FB Back FB Top FB Bottom Catalyst Exit...
Page 58
Run 1 Emissions WOODSTOVE SURFACE TEMPERATURE DATA Client: Hearth and Home Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/3/2019 Stove Δ Temperature Data (°F) Stove Surface Elapsed Time (min) FB Left FB Right FB Back FB Top FB Bottom Catalyst Exit...
Page 59
Run 1 Emissions WOODSTOVE SURFACE TEMPERATURE DATA Client: Hearth and Home Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/3/2019 Stove Δ Temperature Data (°F) Stove Surface Elapsed Time (min) FB Left FB Right FB Back FB Top FB Bottom Catalyst Exit...
Page 60
Run 1 Emissions.xlsm LAB SAMPLE DATA - ASTM E2515 Client: Hearth and Home Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: AK Date: 12/3/2019 Sample ID Tare, mg Total, mg Final, mg Catch, mg Train A Filters - 3637 124.1 121.6...
Page 61
ASTM E2780 Wood Heater Run Sheets Client: HHT Job Number: 19-538 Tracking #: 0050 Model: 4300ACC-C Run Number: 1 Test Date: 12/3/19 Wood Heater Run Notes Test Control Settings Open 0.443” (~0.05” from fixed stop) Primary Air Setting(s): Targeted Burn Category: Preburn Notes Time Notes...
Page 62
ASTM E2780 Wood Heater Run Sheets Client: HHT Job Number: 19-538 Tracking #: 0050 Model: 4300ACC-C Run Number: 1 Test Date: 12/3/19 Test Fuel Side View Test Fuel Iso View Test Fuel Loaded in Stove Air Setting Technician Signature: Date: 12/18/2019 Page 2 of 2...
Page 63
WOOD STOVE TEST DATA PACKET ASTM E2780/E2515 Run 2 Data Summary Client: Model: 4300ACC-C Job #: 19-538 Tracking #: 0050 Test Date: 12/4/2019 12/18/2019 Techician Signature Date PFS-TECO Page 1 of 35...
Page 64
Run 2 Emissions TEST RESULTS - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/4/2019 1.09 Burn Rate (kg/hr): Ambient Sample Sample 1st Hour Filter Sample Train A Train B Total Sample Volume (ft 0.000 52.694...
Page 65
Run 2 Emissions B415.1 Efficiency Results Manufacturer: HHT Model: 4300ACC-C Date: 12/04/19 Run: Control #: 19-538 Test Duration: Output Category: Test Results in Accordance with CSA B415.1-09 HHV Basis LHV Basis Overall Efficiency 74.7% 80.7% Combustion Efficiency 93.3% 93.3% Heat Transfer Efficiency 80.0% 86.5% Output Rate (kJ/h)
Page 67
Run 2 Emissions DILUTION TUNNEL & MISC. DATA - ASTM E2780 / E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Test Start Time: 11:18 Date: 12/4/2019 Total Sampling Time (min): Pre-Test Post Test Avg. Barometric Pressure (in. Hg) Recording Interval (min): 28.37 28.38...
Page 68
Run 2 Emissions WOODSTOVE PREBURN DATA - ASTM E2780 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/4/2019 Recording Interval (min): Run Time (min): Temperatures (°F) Elapsed Scale Stove Flue Draft Time Reading FB Left FB Right FB Back FB Top FB Bottom Surface...
Page 69
Run 2 Emissions WOODSTOVE PREBURN DATA - ASTM E2780 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/4/2019 Recording Interval (min): Run Time (min): Temperatures (°F) Elapsed Scale Stove Flue Draft Time Reading FB Left FB Right FB Back FB Top FB Bottom Surface...
Page 70
Run 2 Emissions BOX A TEST DATA - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/4/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Elapsed Dilution Orifice Meter Gas Meter Sample Meter...
Page 71
Run 2 Emissions BOX A TEST DATA - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/4/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Elapsed Dilution Orifice Meter Gas Meter Sample Meter...
Page 72
Run 2 Emissions BOX A TEST DATA - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/4/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Elapsed Dilution Orifice Meter Gas Meter Sample Meter...
Page 73
Run 2 Emissions BOX A TEST DATA - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/4/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Elapsed Dilution Orifice Meter Gas Meter Sample Meter...
Page 74
Run 2 Emissions BOX A TEST DATA - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/4/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Elapsed Dilution Orifice Meter Gas Meter Sample Meter...
Page 75
Run 2 Emissions BOX A TEST DATA - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/4/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Elapsed Dilution Orifice Meter Gas Meter Sample Meter...
Page 76
Run 2 Emissions BOX A TEST DATA - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/4/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Elapsed Dilution Orifice Meter Gas Meter Sample Meter...
Page 77
Run 2 Emissions BOX A TEST DATA - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/4/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Elapsed Dilution Orifice Meter Gas Meter Sample Meter...
Page 78
Run 2 Emissions BOX A TEST DATA - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/4/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Elapsed Dilution Orifice Meter Gas Meter Sample Meter...
Page 79
Run 2 Emissions BOX A TEST DATA - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/4/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Elapsed Dilution Orifice Meter Gas Meter Sample Meter...
Page 80
Run 2 Emissions BOX B TEST DATA - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/4/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter...
Page 81
Run 2 Emissions BOX B TEST DATA - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/4/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter...
Page 82
Run 2 Emissions BOX B TEST DATA - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/4/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter...
Page 83
Run 2 Emissions BOX B TEST DATA - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/4/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter...
Page 84
Run 2 Emissions BOX B TEST DATA - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/4/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter...
Page 85
Run 2 Emissions BOX B TEST DATA - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/4/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter...
Page 86
Run 2 Emissions BOX B TEST DATA - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/4/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter...
Page 87
Run 2 Emissions BOX B TEST DATA - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/4/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter...
Page 88
Run 2 Emissions BOX B TEST DATA - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/4/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter...
Page 89
Run 2 Emissions BOX B TEST DATA - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/4/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter...
Page 90
Run 2 Emissions WOODSTOVE SURFACE TEMPERATURE DATA Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/4/2019 Stove Δ Temperature Data (°F) Stove Surface Elapsed Time (min) FB Left FB Right FB Back FB Top FB Bottom Catalyst Exit Average 391.0...
Page 91
Run 2 Emissions WOODSTOVE SURFACE TEMPERATURE DATA Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/4/2019 Stove Δ Temperature Data (°F) Stove Surface Elapsed Time (min) FB Left FB Right FB Back FB Top FB Bottom Catalyst Exit Average 405.8...
Page 92
Run 2 Emissions WOODSTOVE SURFACE TEMPERATURE DATA Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/4/2019 Stove Δ Temperature Data (°F) Stove Surface Elapsed Time (min) FB Left FB Right FB Back FB Top FB Bottom Catalyst Exit Average 371.6...
Page 93
Run 2 Emissions WOODSTOVE SURFACE TEMPERATURE DATA Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/4/2019 Stove Δ Temperature Data (°F) Stove Surface Elapsed Time (min) FB Left FB Right FB Back FB Top FB Bottom Catalyst Exit Average 311.8...
Page 94
Run 2 Emissions WOODSTOVE SURFACE TEMPERATURE DATA Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/4/2019 Stove Δ Temperature Data (°F) Stove Surface Elapsed Time (min) FB Left FB Right FB Back FB Top FB Bottom Catalyst Exit Average 293.4...
Page 95
Run 2 Emissions WOODSTOVE SURFACE TEMPERATURE DATA Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/4/2019 Stove Δ Temperature Data (°F) Stove Surface Elapsed Time (min) FB Left FB Right FB Back FB Top FB Bottom Catalyst Exit Average 292.4...
Page 96
Run 2 Emissions WOODSTOVE SURFACE TEMPERATURE DATA Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/4/2019 Stove Δ Temperature Data (°F) Stove Surface Elapsed Time (min) FB Left FB Right FB Back FB Top FB Bottom Catalyst Exit Average 310.4...
Page 97
Run 2 Emissions.xlsm LAB SAMPLE DATA - ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: AK Date: 12/4/2019 Sample ID Tare, mg Total, mg Final, mg Catch, mg Train A Filters - 3643 124.9 123.2 123.2 First Hour...
Page 98
ASTM E2780 Wood Heater Run Sheets Client: HHT Job Number: 19-538 Tracking #: 0050 Model: 4300ACC-C Run Number: 2 Test Date: 12/4/19 Wood Heater Run Notes Test Control Settings Primary Air Setting(s): Open 0.75” Targeted Burn Category: Preburn Notes Time Notes 10:00 Added final preburn fuel...
Page 99
ASTM E2780 Wood Heater Run Sheets Client: HHT Job Number: 19-538 Tracking #: 0050 Model: 4300ACC-C Run Number: 2 Test Date: 12/4/19 Test Fuel Side View Test Fuel Iso View Test Fuel Loaded in Stove Air Setting Technician Signature: Date: 12/18/2019 Page 2 of 2...
Page 100
WOOD STOVE TEST DATA PACKET ASTM E2780/E2515 Run 3 Data Summary Client: Model: 4300ACC-C Job #: 19-538 Tracking #: 0050 Test Date: 12/5/2019 12/18/2019 Techician Signature Date PFS-TECO Page 1 of 24...
Page 101
Run 3 Emissions TEST RESULTS - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/5/2019 1.74 Burn Rate (kg/hr): Ambient Sample Sample 1st Hour Filter Sample Train A Train B Total Sample Volume (ft 0.000 32.015...
Page 102
Run 3 Emissions B415.1 Efficiency Results Manufacturer: HHT Model: 4300ACC-C Date: 12/05/19 Run: Control #: 19-538 Test Duration: Output Category: Test Results in Accordance with CSA B415.1-09 HHV Basis LHV Basis Overall Efficiency 73.8% 79.7% Combustion Efficiency 96.3% 96.3% Heat Transfer Efficiency 76.6% 82.7% Output Rate (kJ/h)
Page 104
Run 3 Emissions DILUTION TUNNEL & MISC. DATA - ASTM E2780 / E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Test Start Time: 14:20 Date: 12/5/2019 Total Sampling Time (min): Pre-Test Post Test Avg. Barometric Pressure (in. Hg) Recording Interval (min): 28.37 28.56...
Page 105
Run 3 Emissions WOODSTOVE PREBURN DATA - ASTM E2780 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/5/2019 Recording Interval (min): Run Time (min): Temperatures (°F) Elapsed Scale Stove Flue Draft Time Reading FB Left FB Right FB Back FB Top FB Bottom Surface...
Page 106
Run 3 Emissions WOODSTOVE PREBURN DATA - ASTM E2780 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/5/2019 Recording Interval (min): Run Time (min): Temperatures (°F) Elapsed Scale Stove Flue Draft Time Reading FB Left FB Right FB Back FB Top FB Bottom Surface...
Page 107
Run 3 Emissions BOX A TEST DATA - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/5/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Elapsed Dilution Orifice Meter Gas Meter Sample Meter...
Page 108
Run 3 Emissions BOX A TEST DATA - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/5/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Elapsed Dilution Orifice Meter Gas Meter Sample Meter...
Page 109
Run 3 Emissions BOX A TEST DATA - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/5/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Elapsed Dilution Orifice Meter Gas Meter Sample Meter...
Page 110
Run 3 Emissions BOX A TEST DATA - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/5/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Elapsed Dilution Orifice Meter Gas Meter Sample Meter...
Page 111
Run 3 Emissions BOX A TEST DATA - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/5/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Elapsed Dilution Orifice Meter Gas Meter Sample Meter...
Page 112
Run 3 Emissions BOX A TEST DATA - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/5/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Elapsed Dilution Orifice Meter Gas Meter Sample Meter...
Page 113
Run 3 Emissions BOX B TEST DATA - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/5/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter...
Page 114
Run 3 Emissions BOX B TEST DATA - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/5/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter...
Page 115
Run 3 Emissions BOX B TEST DATA - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/5/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter...
Page 116
Run 3 Emissions BOX B TEST DATA - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/5/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter...
Page 117
Run 3 Emissions BOX B TEST DATA - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/5/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter...
Page 118
Run 3 Emissions BOX B TEST DATA - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/5/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter...
Page 119
Run 3 Emissions WOODSTOVE SURFACE TEMPERATURE DATA Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/5/2019 Stove Δ Temperature Data (°F) Stove Surface Elapsed Time (min) FB Left FB Right FB Back FB Top FB Bottom Catalyst Exit Average 426.0...
Page 120
Run 3 Emissions WOODSTOVE SURFACE TEMPERATURE DATA Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/5/2019 Stove Δ Temperature Data (°F) Stove Surface Elapsed Time (min) FB Left FB Right FB Back FB Top FB Bottom Catalyst Exit Average 462.0...
Page 121
Run 3 Emissions WOODSTOVE SURFACE TEMPERATURE DATA Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/5/2019 Stove Δ Temperature Data (°F) Stove Surface Elapsed Time (min) FB Left FB Right FB Back FB Top FB Bottom Catalyst Exit Average 430.6...
Page 122
Run 3 Emissions WOODSTOVE SURFACE TEMPERATURE DATA Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/5/2019 Stove Δ Temperature Data (°F) Stove Surface Elapsed Time (min) FB Left FB Right FB Back FB Top FB Bottom Catalyst Exit Average 383.0...
Page 123
Run 3 Emissions.xlsm LAB SAMPLE DATA - ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: AK Date: 12/5/2019 Sample ID Tare, mg Total, mg Final, mg Catch, mg Train A Filters - 3648 123.5 121.9 121.9 First Hour...
Page 124
ASTM E2780 Wood Heater Run Sheets Client: HHT Job Number: 19-538 Tracking #: 0050 Model: 4300ACC-C Run Number: 3 Test Date: 12/5/19 Wood Heater Run Notes Test Control Settings Primary Air Setting(s): Fully open, rear air fully closed Targeted Burn Category: Preburn Notes Time Notes...
Page 125
ASTM E2780 Wood Heater Run Sheets Client: HHT Job Number: 19-538 Tracking #: 0050 Model: 4300ACC-C Run Number: 3 Test Date: 12/5/19 Test Fuel Side View Test Fuel Iso View Test Fuel Loaded in Stove Air Setting Technician Signature: Date: 12/18/2019 Page 2 of 2...
Page 126
WOOD STOVE TEST DATA PACKET ASTM E2780/E2515 Run 4 Data Summary Client: Model: 4300ACC-C Job #: 19-538 Tracking #: 0050 Test Date: 12/5/2019 12/18/2019 Techician Signature Date PFS-TECO Page 1 of 21...
Page 127
Run 4 Emissions TEST RESULTS - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/5/2019 2.79 Burn Rate (kg/hr): Ambient Sample Sample 1st Hour Filter Sample Train A Train B Total Sample Volume (ft 0.000 19.953...
Page 128
Run 4 Emissions B415.1 Efficiency Results Manufacturer: HHT Model: 4300ACC-C Date: 12/05/19 Run: Control #: 19-538 Test Duration: Output Category: Test Results in Accordance with CSA B415.1-09 HHV Basis LHV Basis Overall Efficiency 71.2% 76.9% Combustion Efficiency 95.9% 95.9% Heat Transfer Efficiency 74.2% 80.2% Output Rate (kJ/h)
Page 130
Run 4 Emissions Quality Checks Requirement Observed Result Fuel Density 25 - 36 (lbs/ft , DB) 29.6 Loading Density 6.3 - 7.7 (lbs/ft , WB) #DIV/0! #DIV/0! 2x4 Fuel Mix 35 - 65 % of total weight PFS-TECO Page 5 of 21...
Page 131
Run 4 Emissions DILUTION TUNNEL & MISC. DATA - ASTM E2780 / E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Test Start Time: 14:20 Date: 12/5/2019 Total Sampling Time (min): Pre-Test Post Test Avg. Barometric Pressure (in. Hg) Recording Interval (min): 28.37 28.38...
Page 132
Run 4 Emissions WOODSTOVE PREBURN DATA - ASTM E2780 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/5/2019 Recording Interval (min): Run Time (min): Temperatures (°F) Elapsed Scale Stove Flue Draft Time Reading FB Left FB Right FB Back FB Top FB Bottom Surface...
Page 133
Run 4 Emissions WOODSTOVE PREBURN DATA - ASTM E2780 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/5/2019 Recording Interval (min): Run Time (min): Temperatures (°F) Elapsed Scale Stove Flue Draft Time Reading FB Left FB Right FB Back FB Top FB Bottom Surface...
Page 134
Run 4 Emissions WOODSTOVE PREBURN DATA - ASTM E2780 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/5/2019 Recording Interval (min): Run Time (min): Temperatures (°F) Elapsed Scale Stove Flue Draft Time Reading FB Left FB Right FB Back FB Top FB Bottom Surface...
Page 135
Run 4 Emissions BOX A TEST DATA - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/5/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Elapsed Dilution Orifice Meter Gas Meter Sample Meter...
Page 136
Run 4 Emissions BOX A TEST DATA - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/5/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Elapsed Dilution Orifice Meter Gas Meter Sample Meter...
Page 137
Run 4 Emissions BOX A TEST DATA - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/5/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Elapsed Dilution Orifice Meter Gas Meter Sample Meter...
Page 138
Run 4 Emissions BOX A TEST DATA - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/5/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Elapsed Dilution Orifice Meter Gas Meter Sample Meter...
Page 139
Run 4 Emissions BOX B TEST DATA - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/5/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter...
Page 140
Run 4 Emissions BOX B TEST DATA - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/5/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter...
Page 141
Run 4 Emissions BOX B TEST DATA - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/5/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter...
Page 142
Run 4 Emissions BOX B TEST DATA - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/5/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter...
Page 143
Run 4 Emissions WOODSTOVE SURFACE TEMPERATURE DATA Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/5/2019 Stove Δ Temperature Data (°F) Stove Surface Elapsed Time (min) FB Left FB Right FB Back FB Top FB Bottom Catalyst Exit Average 532.0...
Page 144
Run 4 Emissions WOODSTOVE SURFACE TEMPERATURE DATA Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/5/2019 Stove Δ Temperature Data (°F) Stove Surface Elapsed Time (min) FB Left FB Right FB Back FB Top FB Bottom Catalyst Exit Average 561.8...
Page 145
Run 4 Emissions WOODSTOVE SURFACE TEMPERATURE DATA Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/5/2019 Stove Δ Temperature Data (°F) Stove Surface Elapsed Time (min) FB Left FB Right FB Back FB Top FB Bottom Catalyst Exit Average 512.4...
Page 146
Run 4 Emissions.xlsm LAB SAMPLE DATA - ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: AK Date: 12/5/2019 Sample ID Tare, mg Total, mg Final, mg Catch, mg Train A Filters - 3653 122.8 118.6 118.6 First Hour...
Page 147
ASTM E2780 Wood Heater Run Sheets Client: HHT Job Number: 19-538 Tracking #: 0050 Model: 4300ACC-C Run Number: 4 Test Date: 12/5/19 Wood Heater Run Notes Test Control Settings Primary Air Setting(s): Fully open, rear air fully open Targeted Burn Category: Preburn Notes Time Notes...
Page 148
ASTM E2780 Wood Heater Run Sheets Client: HHT Job Number: 19-538 Tracking #: 0050 Model: 4300ACC-C Run Number: 4 Test Date: 12/5/19 Test Fuel Side View Test Fuel Iso View Test Fuel Loaded in Stove Air Setting Technician Signature: Date: 12/18/2019 Page 2 of 2...
Page 149
WOOD STOVE TEST DATA PACKET ASTM E2780/E2515 Run 5 Data Summary Client: Model: 4300ACC-C Job #: 19-538 Tracking #: 0050 Test Date: 12/6/2019 12/18/2019 Techician Signature Date PFS-TECO Page 1 of 36...
Page 150
Run 5 Emissions TEST RESULTS - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/6/2019 1.07 Burn Rate (kg/hr): Ambient Sample Sample 1st Hour Filter Sample Train A Train B Total Sample Volume (ft 0.000 52.782...
Page 151
Run 5 Emissions B415.1 Efficiency Results Manufacturer: HHT Model: 4300ACC-C Date: 12/06/19 Run: Control #: 19-538 Test Duration: Output Category: Test Results in Accordance with CSA B415.1-09 HHV Basis LHV Basis Overall Efficiency 74.8% 80.8% Combustion Efficiency 93.3% 93.3% Heat Transfer Efficiency 80.1% 86.6% Output Rate (kJ/h)
Page 153
Run 5 Emissions DILUTION TUNNEL & MISC. DATA - ASTM E2780 / E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Test Start Time: 10:48 Date: 12/6/2019 Total Sampling Time (min): Pre-Test Post Test Avg. Barometric Pressure (in. Hg) Recording Interval (min): 28.44 28.44...
Page 154
Run 5 Emissions WOODSTOVE PREBURN DATA - ASTM E2780 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/6/2019 Recording Interval (min): Run Time (min): Temperatures (°F) Elapsed Scale Stove Flue Draft Time Reading FB Left FB Right FB Back FB Top FB Bottom Surface...
Page 155
Run 5 Emissions WOODSTOVE PREBURN DATA - ASTM E2780 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/6/2019 Recording Interval (min): Run Time (min): Temperatures (°F) Elapsed Scale Stove Flue Draft Time Reading FB Left FB Right FB Back FB Top FB Bottom Surface...
Page 156
Run 5 Emissions WOODSTOVE PREBURN DATA - ASTM E2780 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/6/2019 Recording Interval (min): Run Time (min): Temperatures (°F) Elapsed Scale Stove Flue Draft Time Reading FB Left FB Right FB Back FB Top FB Bottom Surface...
Page 157
Run 5 Emissions BOX A TEST DATA - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/6/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Elapsed Dilution Orifice Meter Gas Meter Sample Meter...
Page 158
Run 5 Emissions BOX A TEST DATA - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/6/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Elapsed Dilution Orifice Meter Gas Meter Sample Meter...
Page 159
Run 5 Emissions BOX A TEST DATA - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/6/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Elapsed Dilution Orifice Meter Gas Meter Sample Meter...
Page 160
Run 5 Emissions BOX A TEST DATA - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/6/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Elapsed Dilution Orifice Meter Gas Meter Sample Meter...
Page 161
Run 5 Emissions BOX A TEST DATA - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/6/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Elapsed Dilution Orifice Meter Gas Meter Sample Meter...
Page 162
Run 5 Emissions BOX A TEST DATA - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/6/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Elapsed Dilution Orifice Meter Gas Meter Sample Meter...
Page 163
Run 5 Emissions BOX A TEST DATA - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/6/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Elapsed Dilution Orifice Meter Gas Meter Sample Meter...
Page 164
Run 5 Emissions BOX A TEST DATA - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/6/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Elapsed Dilution Orifice Meter Gas Meter Sample Meter...
Page 165
Run 5 Emissions BOX A TEST DATA - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/6/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Elapsed Dilution Orifice Meter Gas Meter Sample Meter...
Page 166
Run 5 Emissions BOX A TEST DATA - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/6/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Elapsed Dilution Orifice Meter Gas Meter Sample Meter...
Page 167
Run 5 Emissions WOODSTOVE SURFACE TEMPERATURE DATA Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/6/2019 Stove Δ Temperature Data (°F) Stove Surface Elapsed Time (min) FB Left FB Right FB Back FB Top FB Bottom Catalyst Exit Average 404.0...
Page 168
Run 5 Emissions WOODSTOVE SURFACE TEMPERATURE DATA Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/6/2019 Stove Δ Temperature Data (°F) Stove Surface Elapsed Time (min) FB Left FB Right FB Back FB Top FB Bottom Catalyst Exit Average 400.2...
Page 169
Run 5 Emissions WOODSTOVE SURFACE TEMPERATURE DATA Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/6/2019 Stove Δ Temperature Data (°F) Stove Surface Elapsed Time (min) FB Left FB Right FB Back FB Top FB Bottom Catalyst Exit Average 386.6...
Page 170
Run 5 Emissions WOODSTOVE SURFACE TEMPERATURE DATA Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/6/2019 Stove Δ Temperature Data (°F) Stove Surface Elapsed Time (min) FB Left FB Right FB Back FB Top FB Bottom Catalyst Exit Average 339.4...
Page 171
Run 5 Emissions WOODSTOVE SURFACE TEMPERATURE DATA Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/6/2019 Stove Δ Temperature Data (°F) Stove Surface Elapsed Time (min) FB Left FB Right FB Back FB Top FB Bottom Catalyst Exit Average 319.2...
Page 172
Run 5 Emissions WOODSTOVE SURFACE TEMPERATURE DATA Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/6/2019 Stove Δ Temperature Data (°F) Stove Surface Elapsed Time (min) FB Left FB Right FB Back FB Top FB Bottom Catalyst Exit Average 314.4...
Page 173
Run 5 Emissions WOODSTOVE SURFACE TEMPERATURE DATA Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/6/2019 Stove Δ Temperature Data (°F) Stove Surface Elapsed Time (min) FB Left FB Right FB Back FB Top FB Bottom Catalyst Exit Average 329.0...
Page 174
Run 5 Emissions BOX B TEST DATA - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/6/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter...
Page 175
Run 5 Emissions BOX B TEST DATA - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/6/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter...
Page 176
Run 5 Emissions BOX B TEST DATA - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/6/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter...
Page 177
Run 5 Emissions BOX B TEST DATA - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/6/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter...
Page 178
Run 5 Emissions BOX B TEST DATA - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/6/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter...
Page 179
Run 5 Emissions BOX B TEST DATA - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/6/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter...
Page 180
Run 5 Emissions BOX B TEST DATA - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/6/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter...
Page 181
Run 5 Emissions BOX B TEST DATA - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/6/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter...
Page 182
Run 5 Emissions BOX B TEST DATA - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/6/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter...
Page 183
Run 5 Emissions BOX B TEST DATA - ASTM E2780 / ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: Date: 12/6/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter...
Page 184
Run 5 Emissions.xlsm LAB SAMPLE DATA - ASTM E2515 Client: Job #: 19-538 Model: 4300ACC-C Tracking #: 0050 Run #: Technician: AK Date: 12/6/2019 Sample ID Tare, mg Total, mg Final, mg Catch, mg Train A Filters - 3658 123.4 120.6 120.6 First Hour...
Page 185
ASTM E2780 Wood Heater Run Sheets Client: HHT Job Number: 19-538 Tracking #: 0050 Model: 4300ACC-C Run Number: 5 Test Date: 12/5/19 Wood Heater Run Notes Test Control Settings Open 0.75”, rear air full closed Primary Air Setting(s): II – Fan confirmation Targeted Burn Category: Preburn Notes Time...
Page 186
ASTM E2780 Wood Heater Run Sheets Client: HHT Job Number: 19-538 Tracking #: 0050 Model: 4300ACC-C Run Number: 5 Test Date: 12/5/19 Test Fuel Side View Test Fuel Iso View Test Fuel Loaded in Stove Air Settings Technician Signature: Date: 12/18/2019 Page 2 of 2...
Page 187
Manufacturer: Hearth and Home Moisture Content M Model: 4300ACC-C 16.3833 Date: 12/03/19 Overall Heating Efficiency: 75.07% 29.69 Run: Combustion Efficiency: 91.95% 485.64 Combustion Efficiency: 91.95% Moisture of Wood (wet basis): 16.3833 Dry kg : 5.61 Control #: 19-538 Heat Transfer Efficiency: 81.65% 13.91 1.32...
Page 196
Test Instruction Recommendations: 4300 Created on/by: 12/2/2019; Joshua Chambers – HHT Design Engineer Purpose: To create repeatability in test protocol for coal bed establishment and loading of the stove. Coal Bed establishment (Low, Medium Low) Wood Load: 2 loads of 2x4’s. Each load will consist of 5 pieces at 11.5” and 4 pieces at 15”. The second wood load should be loaded when the first load has burnt down to around 2 pounds.
Page 197
Fan Settings: Unit fan should be on high for the duration of pre-burn. Coal Bed Break Down: Coal Bed should be broken down at 55 minutes into pre-burn. Rake coals forward to create a slight slope parallel to the unit’s baffle. Clear out coals directly in front of the primary air outlet.
Page 198
the 2x4 on it’s side. Make sure the 2x4 on its side is not touching the bricks. If necessary, move coals that are blocking the primary air outlet. Air Controls: Before opening the door to load, open primary air control and ACC. At 5 minutes, activate ACC and leave primary air control open.
Page 199
Copy of Conditioning Data.xlsm Conditioning Data Client: Job #: 19-538 Model: 43M-ACC-C Tracking #: 0050 Date(s): Technician: All conditioning was conducted with douglas fir of moisture content 19-25% DB. Air setting used was medium (open 0.75") Average: 315.2 74.4 Catalyst Exit...
Page 200
Run 2 Emissions Sample Calculations – ASTM E2780 & E2515 Client: Model: 4300ACC-C Run: Equations used to calculate the parameters listed below are described in this appendix. Sample calculations are provided for each equation. The raw data and printout results from a sample run are also provided for comparison to the sample calculations.
Page 201
Run 2 Emissions – Weight of test fuel spacers, dry basis, kg ASTM E2780 equation (1) = (M )(100/(100 + FM Where, average fuel moisture of test fuel spacers, % dry basis weight of test fuel spacers, wet basis, kg Sample Calculation: 10.0 % 2.1 lbs...
Page 202
Run 2 Emissions – Weight of test fuel crib, excluding nails and spacers, dry basis, kg ASTM E2780 equation (2) = Σ[(M )(100/(100 + FM CPnwb Where, weight of each test fuel piece n in fuel crib, excluding nails and spacers, wet basis, kg CPnwb Average fuel moisture of test fuel n in fuel crib, % dry basis Sample Calculation (test fuel piece 1):...
Page 203
Run 2 Emissions - Density of fuel crib, excluding spacers and nails, dry basis, lbs/ft ASTM E2780 equation (3) Where, = Volume of fuel crib, ft Sample calculation: 623.9 1728 = conversion from in to ft 10.72 / 623.9 * 1728 lbs/ft 29.7 PFS-TECO...
Page 204
Run 2 Emissions - Total weight of fuel crib excluding nails, dry basis, kg FTAdb ASTM E2780 equation (4) FTAdb Sample calculation: = 0.87 + 4.86 FTAdb 5.73 kg PFS-TECO Page 5 of 15...
Page 205
Run 2 Emissions BR – dry burn rate, kg/hr ASTM E2780 equation (5) 60 M FTAdb θ Where, θ = Total length of test run, min Sample Calculation: = 5.73 θ = 316 60 x 5.73 1.09 kg/hr PFS-TECO Page 6 of 15...
Page 206
Run 2 Emissions – Average gas velocity in the dilution tunnel, ft/sec ASTM E2515 equations (9) Where: strav Adjustment factor for pitot tube center point reading = , ASTM E2515 Equation (1) scent Dilution tunnel velocity calculated after the multi-point pitot traverse at the center, ft/sec scent Dilution tunnel velocity calculated after the multi-point pitot traverse, ft/sec strav...
Page 207
Run 2 Emissions – Average gas flow rate in dilution tunnel, dscf/hr ASTM E2515 equation (3) Where: 3600 Conversion from seconds to hours (ASTM method uses 60 to convert in minutes) Water vapor in gas stream, proportion by volume; assume 2% Cross sectional area of dilution tunnel, ft Standard absolute temperature, 528 °R Absolute average gas static pressure in dilution tunnel, = P...
Page 208
Run 2 Emissions – Volume of Gas Sampled Corrected to Dry Standard Conditions, dscf m(std) ASTM E2515 equation (6) Where: 17.64 °R/in. Hg Volume of gas sample measured at the dry gas meter, dcf Dry gas meter calibration factor, dimensionless Barometric pressure at the testing site, in.
Page 209
Run 2 Emissions – Total Particulate Matter Collected, mg ASTM E2515 Equation (12) Where: mass of particulate matter from probe, mg mass of particulate matter from filters, mg mass of particulate matter from filter seals, mg Sample Calculation: Using equation for Train A (first hour): Using equation for Train A (post-first hour): Train A aggregate: Using equation for Train B:...
Page 210
Run 2 Emissions - Concentration of particulate matter in tunnel gas, dry basis, corrected to STP, g/dscf ASTM E2515 equation (13) Where: Constant, 0.001 g/mg Total mass of particulate matter collected in the sampling train, mg Volume of gas sampled corrected to dry standard conditions, dscf m(std) Sample calculation: For Train 1:...
Page 211
Run 2 Emissions – Total Particulate Emissions, g ASTM E2515 equation (15) Where: Concentration of particulate matter in tunnel gas, g/dscf Concentration particulate matter room air, g/dscf Average dilution tunnel gas flow rate, dscf/hr θ Total time of test run, minutes Sample calculation: For Train 1 = ( 0.000103 - 0...
Page 212
Run 2 Emissions PR - Proportional Rate Variation ASTM E2515 equation (16) Where: θ = Total sampling time, min θ = Length of recording interval, min = Volume of gas sample measured by the dry gas meter during the “ith” time interval, dcf = Volume of gas sample as measured by dry gas meter, dcf = Average gas velocity in the dilution tunnel during the "ith"...
Page 213
Run 2 Emissions – Particulate emissions for test run, g/hr ASTM E2780 equation (6) = 60 (E /θ) Where, = Total particulate emissions, grams θ = Total length of full integrated test run, min Sample Calculation: (Dual train average) = 6.41 g θ...
Page 214
Run 2 Emissions – Particulate emission factor for test run, g/dry kg of fuel burned ASTM E2780 equation (7) FTAdb Sample Calculation: (Dual train average) = 6.41 g 5.73 kg 6.41 / 5.73 1.12 g/kg PFS-TECO Page 15 of 15...
Page 219
28R Weighted Average EPA Method 28R Weighted Average Emissions Client: Stove Model: 4300 Test Dates: 12/2/19-12/5/19 Job Number: 19-538 Signature/Date: Weighted Average Particulate Emissions (g/hr): 1.60 Weighted Average HHV Efficiency (%): 74.2% Weighted Average LHV Efficiency (%): 80.2% Average CO Emissions (g/min): Individual Run Summaries Run Number: Run Number:...
Page 230
RELEASED ITEM PART NUMBER PART NAME 8390-079 SERIAL RATING PLATE HOT WHILE IN OPERATION DO NOT TOUCH, KEEP CHILDREN AND CLOTHING AWAY. CONTACT MAY CAUSE SKIN BURNS. KEEP FURNISHINGS AND OTHER CAUTION COMBUSTIBLE MATERIAL FAR AWAY FROM THE APPLIANCE. SEE NAMEPLATE AND INSTRUCTIONS. CHAUD LORS DE L'OPÉRATION.
Page 231
HOT WHILE IN OPERATION DO NOT TOUCH, KEEP CHILDREN AND CLOTHING AWAY. CONTACT MAY CAUSE SKIN BURNS. KEEP FURNISHINGS AND OTHER CAUTION COMBUSTIBLE MATERIAL FAR AWAY FROM THE APPLIANCE. SEE NAMEPLATE AND INSTRUCTIONS. CHAUD LORS DE L' O PÉRATION. NE PAS TOUCHER. GARDEZ LES ENFANTS ET LES VÊTEMENTS LOIN DE L' E SPACE DÉSIGNÉ DE L' I NSTALLATION. LE CONTACT PEUT CAUSER DES ATTENTION: BRÛLURES À...
Owner’s Manual Operation & Care INSTALLER: Leave this manual with party responsible for use and operation. OWNER: Retain this manual for future reference. Contact your dealer with questions on installation, operation, or service. NOTICE: DO NOT DISCARD THIS MANUAL WARNING If the information in these instructions is not followed exactly, a fire could result causing property damage, personal injury,...
Page 233
Welcome to the Quadra-Fire Family NOTE: Clearances may only be reduced by means approved by the regulatory authority having jurisdiction A. Sample of Serial Number / Safety Label LOCATION: Back of appliance CAUTION HOT WHILE IN OPERATION DO NOT TOUCH, KEEP CHILDREN AND CLOTHING AWAY. CONTACT MAY CAUSE SKIN BURNS. KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIAL FAR AWAY FROM THE APPLIANCE.
Page 234
Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury. • WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury. • CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. •...
B. Warranty Policy Hearth & Home Technologies LLC LIMITED WARRANTY Hearth & Home Technologies LLC (“HHT”) extends the following warranty for HHT gas, wood, pellet and electric hearth appliances (each a “Product” and collectively, the “Product(s)”) and certain component parts set forth in the table below (“Component Part(s)”) that are purchased from a HHT authorized dealer or distributor.
WARRANTY CONDITIONS: • Because HHT cannot control the quality of any Products sold by unauthorized sellers, this Warranty only covers Products that are purchased through an HHT authorized dealer or distributor unless otherwise prohibited by law; a list of HHT authorized dealers is available on the HHT branded websites.
C. Quick Start Guide NOTE: These are generic drawings and may not represent your specifi c model. 10 Pieces of Newspaper, 10-20 Pieces of Dry ITEMS NEEDED FOR FIRST FIRE: Kindling and Few Pieces of Dry Split Wood. OPEN AIR CONTROLS LOAD WOOD ADD NEWSPAPER...
D. Glass Specifications WARNING This appliance is equipped with 5mm ceramic glass. Replace glass only with 5mm ceramic glass. Please contact Fire Risk. your dealer for replacement glass. Hearth & Home Technologies disclaims any E. Mobile Home Approved responsibility for, and the warranty will be voided by, the following actions: •...
Operating Instructions A. Over-Firing Your Appliance Splitting wood before it is stored reduces drying time. Wood should be stacked so that both ends of each piece are exposed to air, since more drying occurs through the WARNING cut ends than the sides. This is true even with wood that has been split.
It is very important to reload your appliance while 2. Medium low burn setting: enough lively hot coals remain in order to provide the - Burn Rate Air Control spring handle up to high position amount of heat needed to dry and rekindle the next load for 5 minutes.
Page 242
WARNING CAUTION Risk of Fire. When set on High Burn Rate and over-riding Injury Risk. the Automatic Combustion Control system an • Gloves recommended over fire situation can occur and may result in a chimney fire. Over firing will void the appliance warranty. Manual Timer Over-Ride: If you need to shut the ACC system off before it goes through the cycle of shutting itself off;...
E. Building A Fire NOTE: Before lighting your first fire in the appliance: • Build fire on brick firebox floor. • Do NOT use grates, andirons or other methods to NOTE: The special high temperature paint that your support fuel. It will adversely affect emissions. appliance is finished with will cure as your appliance heats.
F. Opacity (Smoke) G. Clear Space This is the measure of how cleanly your appliance is burning. NOTE: Do NOT place combustible objects within Opacity is measured in percent; 100% opacity is when an 4 ft (1.2m) of the front of appliance (Figure 13.1). object is totally obscured by the smoke column from a chimney, and 0% opacity means that no smoke column can •...
H. Negative Pressure I. Frequently Asked Questions ISSUES SOLUTIONS WARNING When first operated, this appliance Asphyxiation Risk. may release an odor for the first • Negative pressure can cause spillage several hours. This is caused by Odor from appliance combustion fumes, soot the curing of the paint and the...
Maintenance and Service A. Quick Reference Maintenance Guide CAUTION When properly maintained, your fireplace will give you many years of trouble-free service. Contact your dealer to answer Allow the appliance to completely cool down before questions regarding proper operation, troubleshooting and performing any cleaning or maintenance.
B. General Maintenance 2. Disposal of Ashes • Frequency: When ash is within 1-3/4 in. (44mm) of firebox 1. Creosote (Chimney) Cleaning • Frequency: Every 2 months during heating season or • By: Homeowner as recommended by a certified chimney sweep; more frequently if chimney exceeds or is under 14-16 ft.
Page 248
4. Glass Cleaning 6. Inspect Firebrick • Frequency: As desired • Frequency: After each ash removal • By: Homeowner • By: Homeowner Replace the firebrick if they become crumbly and/or if there CAUTION is a 1/4 inch (6.35mm) gap between the bricks. The firebox is lined with firebrick, which has exceptional Handle glass assembly with care.
C. Correct Baffle & Blanket Placement INCORRECT POSITIONS WARNING Fire Risk. Firebox damage due to improper baffle placement is not covered by warranty. Operate the wood burning appliance with the baffle in the correct position only. Not doing so could result in: •...
Troubleshooting Guide With proper installation, operation, and maintenance your wood appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist you or a qualified service person in the diagnosis of a problem and the corrective action to be taken.
Service Parts Replacement A. Glass CAUTION NOTE: Replace with 5mm ceramic glass only. Service Part: 7000-012 Handle glass assembly with care. Glass Assembly When cleaning glass: 1. Ensure that the fire is out and the appliance is cool to the touch.
B. Firebrick C. Door Handle Assembly Replace the firebrick if they become crumbly and/or if there NOTE: DO NOT over tighten locking nut; door handle is a 1/4 inch (6.35mm) gap between the bricks. needs to move smoothly! Inspect the firebrick after each ash removal. 1.
D. Baffle Baffle Board even with front tube & resting on all tubes Service Part: SRV7037-112 1. Remove all ash from the firebox, and extinguish all hot embers before disposal into a metal container. 2. The baffle board has 2 pieces. With the ceramic blanket still in place, slide one baffle piece over the top of other Burn Rate Air one and pull out top piece through the door opening and...
E. Tube Channel Assembly NOTE: Service Space Service Part: SRV7033-023 In order to replace the tube channel assembly a clearance Removing Tube Channel Assembly of 19 inches (483mm) is required on the right side of appliance in order to remove the tubes with the appliance 1.
B. Service Parts List 43M-ACC-C Service Parts Wood Stove Beginning Manufacturing Date: Jan 2020 Ending Manufacturing Date: Active Part number list on following page. 04/24 8390-077A 08/24...
43M-ACC-C Service Parts Beginning Manufacturing Date: Jan 2020 Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor. Hearth and Home Technologies does not sell directly to consumers. Stocked Provide model number and serial number when requesting service parts from your dealer at Depot or distributor.
Page 258
832-0990 13.5 Cam Latch SRV430-1141 13.6 Nut, Locking Door Handle Pkg of 24 226-0100/24 Component Pack: (Spring Handles(1) 1/2” & (2) 1/4”, 2 Nickel 436-5360 Hinge Pins, & Quadra-Fire Logo) Additional service part numbers appear on following page. 8390-077A 08/24...
Page 259
43M-ACC-C Service Parts Beginning Manufacturing Date: Jan 2020 Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION . Parts must be ordered from a dealer or Stocked Hearth and Home Technologies does not sell directly to consumers distributor. . Provide model number and serial number when requesting service parts from your dealer or distributor.
Page 260
43M-ACC-C Service Parts Beginning Manufacturing Date: Jan 2020 Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION . Parts must be ordered from a dealer or Stocked Hearth and Home Technologies does not sell directly to consumers distributor. . Provide model number and serial number when requesting service parts from your dealer or distributor.
CONTACT INFORMATION Hearth & Home Technologies 352 Mountain House Road Halifax, PA 17032 Division of HNI INDUSTRIES Please contact your Forge & Flame dealer with any questions or concerns. For the number of your nearest Forge & Flame dealer log onto www.forgenfl ame.com CAUTION DO NOT DISCARD THIS MANUAL •...
Installation Manual Installation & Appliance Set-Up INSTALLER: Leave this manual with party responsible for use and operation. OWNER: Retain this manual for future reference. NOTICE: DO NOT DISCARD THIS MANUAL WARNING If the information in these instructions is not followed exactly, a fire could result causing property damage, personal injury, WOOD PRO 300 or death.
Page 263
Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury. • WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury. • CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. •...
D. Mobile Home Approved I. California - Prop65 • This appliance is approved for mobile home installations; WARNING when not installed in a sleeping room and when an outside combustion air inlet is provided. This product and the fuels used to operate this product (wood), and the products of combustion of such fuels, can expose you to chemicals •...
Getting Started A. Design and Installation Considerations B. Fire Safety Consideration must be given to: To provide reasonable fire safety, the following should be given serious consideration: • Safety 1. Install at least one smoke detector on each floor of your •...
E. Inspection of Appliance and Components To minimize the effects of negative air pressure: • Install optional outside air kit with the intake facing • Remove appliance and components from packaging and prevailing winds during the heating season inspect for damage. •...
G. Install Checklist ATTENTION INSTALLER: Follow this Standard Work Checklist This standard work checklist is to be used by the installer in conjuction with, not instead of, the instructions contained in this installation manual. _________________________________________________________________________________ Customer: ______________________________________________________________________________ Date Installed: ______________________________________________________________________________ Lot / Address: ________________________________________________________________________ Location of Appliance:...
B. Hearth Protection Requirements CAUTION EMBER PROTECTION: Ember protection shall be either a Type 1 floor protector or made of non-combustible material to Hearth and Home Technologies does not recommend adhesive the requirements below. based vinyl flooring due to thermal expansion. Floating-style flooring (LVP - luxury vinyl plank or LVT –...
C. Clearances to Combustibles Note: If mantle clearance specifications are not listed or to reduce mantle clearances you can follow NFPA211 regulations to assure safe installation of this product. Please consult with your local building inspector before attempting any clearance reductions.
Chimney Systems A. Locating Your Appliance & Chimney • Consider the appliance location in order to avoid floor and ceiling attic joists and rafters. Location of the appliance and chimney will affect • Locate termination cap away from trees, adjacent performance.
B. Chimney Termination Requirements NOTICE: Locating the appliance in a basement or in a location of considerable air movement can cause Follow manufacturer’s instructions for clearance, securing intermittent smoke spillage from appliance. Do not locate flashing and terminating the chimney (Figure 12.1 and appliance near Figure 12.2).
D. Chimney Height / Rise and Run Chimney: The chimney can be new or existing, masonry or This product was designed for and tested on a 6 inch prefabricated and must meet the following minimum (152mm) chimney, 14 to 16 feet (420-480cm) high, requirements and as specified in Chimney Systems.
Page 275
Thimble Listed Termination Cap Site constructed for masonry chimney installation: Components Storm Collar A minimum length of 12 inches [305mm] (longer for thicker Flashing walls) of solid insulated factory-built chimney length constructed to UL 103 Type HT 6 inch (152mm) inside diameter.
G. Installing Chimney Components Solid Pack Chimney with Metal Supports as a Thimble Chimney Connector Single wall connector or appliance pipe. This must be at least 24 gauge mild steel or 26 gauge blue Fire Clay Flue steel. The sections must be attached to the appliance and Liner with Airspace to each other with the crimped (male) end pointing toward the appliance.
Appliance Set-Up A. Outside Air Kit Installation WARNING A source of air (oxygen) is necessary in order for combustion to take place. Whatever combustion air is consumed by the Asphyxiation Risk. fire must be replaced. Air is replaced via air leakage around Outside air inlet must be located to prevent windows and under doors.
Mobile Home Installation You must use a Outside Air Kit Part OAK-ACC; and CAUTION (depending on floor installation), Part SRV7033-041 for installation in a mobile home. THE STRUCTURAL INTEGRITY OF THE MOBILE 1. An outside air inlet must be provided for combustion HOME FLOOR, WALL AND CEILING/ROOF MUST (See page 16...
CONTACT INFORMATION Hearth & Home Technologies 352 Mountain House Road Halifax, PA 17032 Division of HNI INDUSTRIES Please contact your Forge & Flame dealer with any questions or concerns. For the number of your nearest Forge & Flame dealer log onto www.forgenfl ame.com CAUTION DO NOT DISCARD THIS MANUAL •...
Page 282
ITEM PART NUMBER PART NAME 7037-800 SERIAL RATING PLATE HOT WHILE IN OPERATION DO NOT TOUCH, KEEP CHILDREN AND CLOTHING AWAY. CONTACT MAY CAUSE SKIN BURNS. KEEP FURNISHINGS AND OTHER CAUTION COMBUSTIBLE MATERIAL FAR AWAY FROM THE APPLIANCE. SEE NAMEPLATE AND INSTRUCTIONS. CHAUD LORS DE L' O PÉRATION.
Page 283
HOT WHILE IN OPERATION DO NOT TOUCH, KEEP CHILDREN AND CLOTHING AWAY. CONTACT MAY CAUSE SKIN BURNS. KEEP FURNISHINGS AND OTHER CAUTION COMBUSTIBLE MATERIAL FAR AWAY FROM THE APPLIANCE. SEE NAMEPLATE AND INSTRUCTIONS. CHAUD LORS DE L' O PÉRATION. NE PAS TOUCHER. GARDEZ LES ENFANTS ET LES VÊTEMENTS LOIN DE L' E SPACE DÉSIGNÉ DE L' I NSTALLATION. LE CONTACT PEUT CAUSER DES ATTENTION: BRÛLURES À...
Page 284
CONTROL (ACC) • vapors and liquids in the vicinity of this or any other appliance. MODELS: • - If appliance or chimney connector 43M-ACC-C your warranty. 43ST-ACC-C • WARNING HOT SURFACES! Glass and other surfaces are hot during operation AND cool down.
Page 285
B. 4300 Millennium Accessories ....30 C. 4300 Step Top Accessories ....31 Quadra-Fire is a registered trademark of Hearth & Home Technologies. 7037-801A...
4300 Wood Appliance Series ACC C. Mobile Home Approved WARNING • installations; when not installed in a sleeping room and Fire Risk • Hearth & Home Technologies disclaims any • • • Installation and use of any damaged appliance. • •...
4300 Wood Appliance Series ACC Install Guide Getting Started A. Design and Installation Considerations B. Fire Safety • Safety • Convenience • • Chimney and chimney connector required located away from the heating appliance and close to the sleeping areas. Follow the smoke detector It is a good idea to plan your installation on paper, using manufacturer’s placement and installation instructions, through the ceiling and roof.
4300 Wood Appliance Series ACC To minimize the effects of negative air pressure: E. Inspection of Appliance and Components • Install optional outside air kit with the intake facing • Remove appliance and components from packaging prevailing winds during the heating season and inspect for damage.
4300 Wood Appliance Series ACC F. Removal of Appliance from Shipping Step Top: Materials not to damage product. 2. Using 7/16 inch socket or wrench, remove and discard WARNING each side, that is attaching the appliance to the pallet Fire Risk. (Figure 7.2).
4300 Wood Appliance Series ACC G. Install Checklist ATTENTION INSTALLER: Follow this Standard Work Checklist This standard work checklist is to be used by the installer in conjuction with, not instead of, the instructions contained in this installation manual. _________________________________________________________________________________ Customer: ______________________________________________________________________________ Date Installed:...
4300 Wood Appliance Series ACC Dimensions and Clearances A. Appliance Dimensions NOTE: 4300 MILLENNIUM PEDESTAL MODEL 26-1/4 in [667mm] 3-5/8 in 13-1/8 in [92mm] [333mm] 6-3/4 in [170mm] 11 in [278mm] 30-1/2 in [773mm] 15-1/8 in [ 383mm] 21 in [533mm] Figure 9.1 - Front View Figure 9.3 - Top View 28-5/8 in [728mm]...
Page 293
4300 Wood Appliance Series ACC 4300 STEP TOP PEDESTAL MODEL 26 in (660mm) 26 in (660mm) 3-1/2 in 13 in [87mm] [330mm] 6-3/4 in [170mm] 11 in 11 in (278mm) (278mm) 34-1/4 in 34-1/4 in (868mm) (868mm) 15-1/8 in (383mm) 15-1/8 in (383mm) 21 in (533mm) 21 in (533mm)
Page 294
4300 Wood Appliance Series ACC 4300 STEP TOP Q ANNE LEG MODEL 26 in [660mm] 3-1/2 in 13 in [87mm] [330mm] 6-3/4 in [170mm] 11 in [278mm] 32-7/8 in [834mm] 15-1/8 in [383mm] 25 in [636mm] Figure 11.1 - Front View Figure 11.3 - Top View 28-5/8 in [728mm] 26-3/8 in [668mm]...
Page 295
4300 Wood Appliance Series ACC 4300 STEP TOP TRADITIONAL LEG MODEL 26 in [660mm] 3-1/2 in 13 in [87mm] [330mm] 6-3/4 in [170mm] 11 in [278mm] 32-7/8 in [834mm] 15-1/8 in [383mm] 23-3/8 in [595mm] Figure 12.1 - Front View Figure 12.3 - Top View 28-5/8 in [728mm] 26-3/8 in [668mm]...
4300 Wood Appliance Series ACC B. Hearth Protection Requirements In Canada, EMBER PROTECTION: It is necessary to install a Type I sides and rear of the appliance unless the hearth pad is placed against the wall (Figure 13.2 or 14.2 on page 14). *Exception: sides of the fuel loading door.
Page 297
4300 Wood Appliance Series ACC STEP-TOP MODEL pad dimensions 31-5/8 in minimum Corner hearth pad dimensions with single wall pipe 41 in minimum 1440mm 54-3/4 in Fuel loading door 8 in 8 in 16 in 16 in 33-1/8 in 785mm from fuel door from fuel door opening...
4300 Wood Appliance Series ACC Chimney Systems A. Locating Your Appliance & Chimney Location of the appliance and chimney will affect • performance. As shown in Figure 16.1 and ceiling attic joists and rafters. • • Locate termination cap away from trees, adjacent envelope.
4300 Wood Appliance Series ACC B. Chimney Termination Requirements NOTICE: Follow manufacturer’s instructions for clearance, securing (Figure 17.1 & 17.2). can cause intermittent smoke spillage from • Must have an approved and Listed cap appliance. Do not locate appliance near •...
4300 Wood Appliance Series ACC D. Chimney Height / Rise and Run Chimney: This product was designed for and tested on a 6 inch Chimney Systems. appliance. The further your stack height or diameter varies Listed Termination Cap affect performance. Roof Brace (if required) Storm Collar Flashing...
Page 302
4300 Wood Appliance Series ACC Thimble Listed Termination Cap Storm Collar Components A minimum length of 12 inches [305mm] (longer for thicker Flashing constructed to UL 103 Type HT Listed Chimney chimney selected. When jurisdiction requires install approved chimney liner in Ceiling Support masonry chimney.
4300 Wood Appliance Series ACC Solid Pack Chimney with Metal Supports as a Thimble G. Installing Chimney Components Chimney Connector Single wall connector or appliance pipe. Fire Clay Flue Liner with Airspace Masonry Chimney Trim Collar Wall Spacer construction is desired in Canada, the installation shall Chimney Section conform to CAN/CSA-B365.
4300 Wood Appliance Series ACC Appliance Set-Up A. Pedestal Assembly & ARS Installation Remove and discard NOTE: Begin installing the ARS System: and discard. (Figure 21.1). (Figure 21.2). Remove 2 bricks for Figure 21.1 installation and then re-install 3/8 open end wrench (Figure 21.2). 5.
Page 305
4300 Wood Appliance Series ACC Ash Removal Spacer Figure 22.1 Figure 22.4 Door latch with the ash door rod locked in place Ped Kit and Ash Removal System (Cont’d) Knob Installing Ped Kit 1. Follow Begin installing the ARS System instructions provided on page 21.
4300 Wood Appliance Series ACC B. Access Cover Handle Ash Removel Insert Access Cover Handle handle into slot of ARS Cover Drawer (Figure 23.4). Adapters Figure 23.1 Figure 23.4 ARS Access Cover C. Leg Kit & ARS Installation Channel NOTE: Begin installing the ARS System.
Page 307
4300 Wood Appliance Series ACC hammer (Figure 21.2 on page 21). Align top holes into the slot on the left side (Figure 21.3 on page 21). and repeat; secure 8. Slide the ash door over the 8 screws protruding nuts and washers using 7/16 socket wrench (Figure 21.3 on page 21).
4300 Wood Appliance Series ACC D. Traditional Leg Installation CAUTION! Installing your traditional legs to your appliance: CHECK BAFFLE BOARDS & CERAMIC BLANKET! of appliance. • in their proper locations. or pallet. • (Figure 25.1). four just removed screws in step 3. NOTE: (Figure 25.1) (Figure 25.1).
4300 Wood Appliance Series ACC E. Door Handle Assembly Installation of Door Handle: 2. Floor & Rear Installation: 1. Slide door handle shaft through hole on door. 2. Add up to three 3/8 washers on the inside of the door. NOTE: The quantity of washers added will change how outside air to appliance intake.
4300 Wood Appliance Series ACC G. Blower (Optional) H. Adjusting The Blower Speed Control adjusted at the factory, and normally does not require further adjustment. rear outer skin as shown in Figure 27.1 1. With the appliance plugged in, turn the speed control wall of appliance.
4300 Wood Appliance Series ACC Mobile Home Installation You must use a Quadra-Fire Outside Air Kit Part 10. Burn seasoned cord wood only. Other types OAK-ACC; which is available from you dealer, for of fuels may generate poisonous gases (e.g., installation in a mobile home.
4300 Wood Appliance Series ACC Reference Materials A. Service & Maintenance Log Date of Service Performed By Description of Service December 19, 2019 7037-801A...
4300 Wood Appliance Series ACC B. 4300 Millennium Accessories 43M-ACC-C Service Parts Beginning Manufacturing Date: Jan 2020 Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION . Parts must be ordered from a dealer or Stocked Hearth and Home Technologies does not sell directly to consumers distributor.
Hearth & Home Technologies 352 Mountain House Road Halifax, PA 17032 Division of HNI INDUSTRIES Please contact your Quadra-Fire dealer with any questions or concerns. For the number of your nearest Quadra-Fire dealer CAUTION DO NOT DISCARD THIS MANUAL •...
Page 316
• vapors and liquids in the vicinity of this or any CONTROL (ACC) other appliance. MODELS: • - If appliance or chimney connector 43M-ACC-C your warranty. 43ST-ACC-C • Comply with all minimum clearances to combustibles WARNING HOT SURFACES! Glass and other surfaces are hot during operation AND cool down.
4300 Wood Stove Series ACC and Welcome to the Quadra-Fire Family NOTE: Clearances may only be reduced by means approved by the regulatory authority having jurisdiction A. Sample of Serial Number / Safety Label LOCATION: Back of appliance HOT WHILE IN OPERATION DO NOT TOUCH, KEEP CHILDREN AND CLOTHING AWAY. CONTACT MAY CAUSE SKIN BURNS. KEEP FURNISHINGS AND OTHER CAUTION COMBUSTIBLE MATERIAL FAR AWAY FROM THE APPLIANCE.
Page 318
E. Using Burn Rate Air Control & ACC System ..12 B. 43M-ACC-C......30 .
4300 Wood Stove Series ACC B. Warranty Policy Hearth & Home Technologies LIMITED LIFETIME WARRANTY Hearth & Home Technologies, on behalf of its hearth brands (“HHT”), extends the following warranty for HHT gas, wood, pellet and electric hearth appliances that are purchased from an HHT authorized dealer. WARRANTY COVERAGE: WARRANTY PERIOD: distributor, whichever occurs earlier.
Page 320
4300 Wood Stove Series ACC WARRANTY CONDITIONS: • This warranty only covers HHT appliances that are purchased through an HHT authorized dealer or distributor. A list of HHT authorized dealers is available on the HHT branded websites. • • This warranty is only valid in the country in which the HHT authorized dealer or distributor that sold the appliance resides. •...
4300 Wood Stove Series ACC This warranty is void if: • • • There is any damage to the appliance or other components due to water or weather damage which is the result of, but not limited LIMITATIONS OF LIABILITY •...
4300 Wood Stove Series ACC C. Quick Start Guide NOTE: 10 Pieces of Newspaper, 10-20 Pieces of Dry ITEMS NEEDED FOR FIRST FIRE: OPEN AIR CONTROLS LOAD WOOD ADD NEWSPAPER HIGH BURN RATE CONTROL (Upper Right Corner) HIGH AUTOMATIC COMBUSTION CONTROL (ACC) (Middle right hand side) Warning! Risk of Fire.
4300 Wood Stove Series ACC Listing and Code Approvals Model: 4300 ACC Series Number: N/A Number: Laboratory: OMNI Test Laboratories, Inc. Report No: 0061WS067S 1.6 grams per hour Emissions: Listed Room Heater, Solid Type: 80.2% Fuel Type 74.2% UL1482-11 (R2015) and ULC Standard: S627-00 and (UM) 84-HUD, Mobile ***EPA BTU Output: 12,200 to 36,800 / hr.
4300 Wood Stove Series ACC WARNING This appliance is equipped with 5mm ceramic glass. Replace glass only with 5mm ceramic glass. Please contact your dealer for replacement glass. Fire Risk. Hearth & Home Technologies disclaims any responsibility for, and the warranty will be D.
Much of the blame for poor air quality Metal warping has been placed on the burning of wood for home heating. In order to improve the situation, we at Quadra-Fire have developed cleaner-burning wood appliances that 2. What To Do if Your Appliance is Over-Firing...
4300 Wood Stove Series ACC 2. Second Stage D. Air Controls The next stage of burning, the secondary stage, is the high and low based on desired heat output, installation maintained and not allowed to go out. This will ensure 1.
4300 Wood Stove Series ACC E. Using Burn Rate Air Control & ACC System 3. Manual Timer Over-Ride If you need to shut the ACC system off before it goes through the cycle of shutting itself off; 25 minutes, CAUTION reach towards the back of the appliance on the right side and pull the lever towards the front of the appliance (Figure 12.2).
Page 328
4300 Wood Stove Series ACC WARNING This wood appliance has a manufacturer-set minimum Risk of Fire. low burn rate that must not be altered. It is against federal When set on High Burn Rate and over-riding regulations to alter this setting or otherwise operate this the Automatic Combustion Control system an wood appliance in a manner inconsistent with operating instructions in this manual.
4300 Wood Stove Series ACC G. Building A Fire NOTE: • • Do NOT use grates, andirons or other methods to NOTE: The special high temperature paint that your support fuel. It will adversely affect emissions. appliance heats. You will notice an odor and perhaps see some vapor rise from the appliance WARNING surface;...
I. Opacity (Smoke) H. Blower Operating Instructions This is the measure of how cleanly your appliance is NOTE: If your Quadra-Fire wood appliance is equipped burning. Opacity is measured in percent; 100% opacity is with an optional blower, you should follow...
4300 Wood Stove Series ACC K. Negative Pressure J. Clear Space NOTE: Do NOT place combustible objects within 4 ft WARNING (1.2 m) of the front of appliance (Figure 16.1). Asphyxiation Risk. • Mantel: • Negative pressure can cause spillage Avoid placing candles and other heat-sensitive objects of combustion fumes, soot and carbon on mantel or hearth.
4300 Wood Stove Series ACC L. Frequently Asked Questions ISSUES SOLUTIONS Odor from appliance caused by the curing of the paint and the burning off of any oils remaining from manufacturing. Noise is caused by metal expanding and contracting as it heats up and cools down, similar to Metallic noise the sound produced by a furnace or heating duct.
4300 Wood Stove Series ACC Maintenance and Service CAUTION! A. Quick Reference Maintenance Guide Allow the appliance to completely cool down before you many years of trouble-free service. Contact your performing any cleaning or maintenance. Start the dealer to answer questions regarding proper operation, troubleshooting and service for your appliance.
4300 Wood Stove Series ACC B. Cleaning and Operating the Ash Removal System WARNING Fire Risk. Make sure Ash Removal System door is sealed tight against the gasket. Air leakage may cause: • • Flame and/or smoke spillage • Wood to burn too fast Figure 19.1 •...
Page 335
4300 Wood Stove Series ACC Formation and Need For Removal: 3. Disposal of Ashes When wood is burned slowly, it produces tar and other • Frequency: When ash is within 1-3/4 in. (44mm) of organic vapors which combine with expelled moisture to form creosote.
Page 336
4300 Wood Stove Series ACC INCORRECT POSITIONS WARNING Fire Risk. placement is not covered by warranty. Operate the wood burning appliance with the Not doing so could result in: • • Overheating the chimney • • Poor performance CAUTION • CORRECT POSITION Ceramic Blanket is NOT in contact with the back of the Back of Firebox...
4300 Wood Stove Series ACC Troubleshooting Guide With proper installation, operation, and maintenance your wood appliance will provide years of trouble-free service. If problem and the corrective action to be taken. Start Fire Problems Possible Cause Solution Not enough kindling/paper or no Use dry kindling, more paper.
NOTE: DO NOT OVER TIGHTEN RETAINERS - can cause glass to break. Magnet 9. Replace the door on the appliance. Spade Quadra-Fire appliances are equipped with ceramic super Connectors heat-resistant glass, which can only be broken by impact Figure 23.1 or misuse.
4300 Wood Stove Series ACC C. Firebrick 2. Remove new brick set from box and lay out to diagram shown below. 3. Lay bottom bricks in appliance. bottom of brick back. the side of the appliance. 4300 Millennium Service Part: SRV7037-003 4300 Step Top Service Part: SRV7037-012 Figure 24.1 Figure 24.4...
4300 Wood Stove Series ACC D. Door Handle Assembly CAUTION DO NOT over tighten lock nut. The door handle needs to move smoothly. 4300 Millennium and 4300 Step Top 4300 Step Top Service Part: SRV7033-071 Service Part: 832-0540 1. Slide door handle through door. 1.
Page 341
4300 Wood Stove Series ACC Service Part: SRV7037-112 (Figure 26.1). 3. Remove the ceramic blanket (Figure 26.2). resting on all tubes (Figure 26.3 and Figure 26.4). (Figure 26.2 and Figure 26.4) (Figure 26.3 and Figure 26.4). Baffle Board even with front tube & resting on all tubes Burn Rate Air Control...
4300 Wood Stove Series ACC F. Tube Channel Assembly Service Part: SRV7033-023 Removing Tube Channel Assembly 1. Remove the right side shield by removing 2 screws in NOTE: Service Space the back using a Phillips head screw driver. In order to replace the tube channel assembly a 2.
4300 Wood Stove Series ACC Reference Materials A. Service & Maintenance Log Date of Service Performed By Description of Service 7037-802A December 19, 2019...
Page 344
4300 Wood Stove Series ACC Date of Service Performed By Description of Service December 19, 2019 7037-802A...
4300 Wood Stove Series ACC B. 43M-ACC-C 43M-ACC-C Service Parts Wood Stove Beginning Manufacturing Date: Jan 2020 Ending Manufacturing Date: Active Part number list on following page. 12/19 7037-802A December 19, 2019...
Page 346
4300 Wood Stove Series ACC 43M-ACC-C Service Parts Beginning Manufacturing Date: Jan 2020 Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor. Hearth and Home Technologies does not sell directly to consumers.
Page 347
Cam Latch SRV430-1141 13.6 Nut, Locking Door Handle Pkg of 24 226-0100/24 Nickel 436-5360 Component Pack: (Spring Handles(1) 1/2” & (2) 1/4”, 2 Hinge Pins, & Quadra-Fire Logo) 436-5350 Door Handle Assembly SRV7033-071 Handle, Fiber SRV7060-212 13.7 13.8 Door Handle...
Page 348
4300 Wood Stove Series ACC 43M-ACC-C Service Parts Beginning Manufacturing Date: Jan 2020 Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION . Parts must be ordered from a dealer or Stocked Hearth and Home Technologies does not sell directly to consumers distributor.
Page 349
4300 Wood Stove Series ACC 43M-ACC-C Service Parts Beginning Manufacturing Date: Jan 2020 Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION . Parts must be ordered from a dealer or Stocked Hearth and Home Technologies does not sell directly to consumers distributor.
4300 Wood Stove Series ACC C. 43ST-ACC-C 43ST-ACC-C Service Parts Beginning Manufacturing Date: Jan 2020 Step Top Model - Wood Stove Ending Manufacturing Date: Active Part number list on following page. 12/19 December 19, 2019 7037-802A...
Page 351
4300 Wood Stove Series ACC 43ST-ACC-C Service Parts Beginning Manufacturing Date: Jan 2020 Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor. Hearth and Home Technologies does not sell directly to consumers. Stocked Provide model number and serial number when requesting service parts from your dealer at Depot...
Page 352
4300 Wood Stove Series ACC 43ST-ACC-C Service Parts Beginning Manufacturing Date: Jan 2020 Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor. Hearth and Home Technologies does not sell directly to consumers. Stocked Provide model number and serial number when requesting service parts from your dealer at Depot...
Page 353
4300 Wood Stove Series ACC 43ST-ACC-C Service Parts Beginning Manufacturing Date: Jan 2020 Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor. Hearth and Home Technologies does not sell directly to consumers. Stocked Provide model number and serial number when requesting service parts from your dealer at Depot...
Page 354
4300 Wood Stove Series ACC 43ST-ACC-C Service Parts Beginning Manufacturing Date: Jan 2020 Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor. Hearth and Home Technologies does not sell directly to consumers. Stocked Provide model number and serial number when requesting service parts from your dealer at Depot...
Page 355
4300 Wood Stove Series ACC 43ST-ACC-C Service Parts Beginning Manufacturing Date: Jan 2020 Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor. Hearth and Home Technologies does not sell directly to consumers. Stocked Provide model number and serial number when requesting service parts from your dealer at Depot...
Page 356
Snap Disc, # 1, Convection Blower SRV230-0470 7033-262 Component Pack SRV7033-051 Upgrade, Door (Nickel Handles, Hinge Pins & Logo) Nickel UK-DRNL Logo, Quadra-Fire Pkg of 10 7000-649/10 Cast Legs, Black Set of 4 TRAD-LEG-BK FASTENERS Avk Rivnut Repair Kit - 1/4-20 & 3/8-16 Rivnut Tools...
Hearth & Home Technologies 352 Mountain House Road Halifax, PA 17032 Division of HNI INDUSTRIES Please contact your Quadra-Fire dealer with any questions or concerns. For the number of your nearest Quadra-Fire dealer CAUTION DO NOT DISCARD THIS MANUAL •...
Page 358
Installation Manual Installation & Appliance Set-Up INSTALLER: Leave this manual with party responsible for use and operation. OWNER: Retain this manual for future reference. NOTICE: DO NOT DISCARD THIS MANUAL WARNING If the information in these instructions is DISCOVERY III WOOD APPLIANCE causing property damage, personal injury, or death.
Page 359
B. Accessories ......21 B. Hearth Protection Requirements ....9 Quadra-Fire is a registered trademark of Hearth & Home Technologies. 7037-803A...
Discovery III C. Mobile Home Approved WARNING • installations; when not installed in a sleeping room and Fire Risk • Hearth & Home Technologies disclaims any • • • Installation and use of any damaged appliance. • • Home Technologies. This appliance is equipped with 5mm ceramic glass.
Discovery III Install Guide Getting Started A. Design and Installation Considerations B. Fire Safety • Safety • Convenience • located away from the heating appliance and close • Chimney and chimney connector required to the sleeping areas. Follow the smoke detector It is a good idea to plan your installation on paper, using manufacturer’s placement and installation instructions, through the ceiling and roof.
Discovery III E. Inspection of Appliance and Components To minimize the effects of negative air pressure: • Install optional outside air kit with the intake facing • Remove appliance and components from packaging prevailing winds during the heating season and inspect for damage. •...
Discovery III G. Install Checklist ATTENTION INSTALLER: Follow this Standard Work Checklist This standard work checklist is to be used by the installer in conjuction with, not instead of, the instructions contained in this installation manual. _________________________________________________________________________________ Customer: ______________________________________________________________________________ Date Installed: ______________________________________________________________________________ Lot / Address: ________________________________________________________________________...
Discovery III Dimensions and Clearances A. Appliance Dimensions NOTE: 26-1/4 in [667mm] 13-1/8 in [337mm] 3-1/2 in 11 in [89mm] [278mm] 6-3/4 in [170mm] 38-3/8 in [975mm] 13-1/4 in [337mm] 15-1/8 in [384mm] 17-7/8 in [454mm] 27-1/4 in [692mm] Figure 8.1 - Front View Figure 8.2 - Top View 28-5/8 in [728mm] 26-3/8 in [670mm]...
Discovery III B. Hearth Protection Requirements In Canada EMBER PROTECTION: It is necessary to install a Type I sides and rear of the appliance unless the hearth pad is placed against the wall (Figure 9.2). Then the clearance *Exception: sides of the fuel loading door. Open the door and measure face of the appliance (*See exception).
Page 367
Discovery III C. Clearances to Combustibles MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS in inches (Millimeters) NOTE: DISCOVERY III WOOD APPLIANCE (2020) INSTALLATION: FULL VERTICAL SINGLE WALL PIPE DISCOVERY III 18-1/2 (470) 11-3/4 (298) 27-1/2 (699) 14-1/2 (368) 8 (254) 20-1/2 (521) 53-1/2 (1359) 12 (305) DOUBLE WALL PIPE...
Discovery III Chimney Systems A. Locating Your Appliance & Chimney • Location of the appliance and chimney will affect and ceiling attic joists and rafters. performance. As shown in Figure 11.1 • • Locate termination cap away from trees, adjacent envelope.
Discovery III B. Chimney Termination Requirements NOTICE: Follow manufacturer’s instructions for clearance, securing (Figure 12.1 and can cause intermittent smoke spillage from Figure 12.2). • Must have an approved and Listed cap • Frequently open doors • • Central heat outlets or returns snow or other material •...
Discovery III D. Chimney Height / Rise and Run Chimney: This product was designed for and tested on a 6 inch appliance. The further your stack height or diameter varies Listed Termination Cap affect performance. Roof Brace (if required) Storm Collar Flashing WARNING Fire Risk.
Page 371
Discovery III Thimble Listed Termination Cap Storm Collar Components A minimum length of 12 inches [305mm] (longer for thicker Flashing constructed to UL 103 Type HT Listed Chimney chimney selected. When jurisdiction requires install approved chimney liner in Ceiling Support masonry chimney.
Discovery III Solid Pack Chimney with Metal Supports as a Thimble G. Installing Chimney Components Chimney Connector Fire Clay Flue Liner with Airspace Masonry Chimney Trim Collar Wall Spacer Chimney Section construction is desired in Canada, the installation shall with 2 inch conform to CAN/CSA-B365.
Discovery III Appliance Set-Up A. Outside Air Kit Installation WARNING Fire Risk. Asphyxiation Risk. air leakage around windows and under doors. In homes that have tightly sealed doors and windows, an outside air • • Enclosed space such as an attic or garage Items Needed for Installation (not supplied) •...
Discovery III B. Decorative Panel Removal & Installation Your appliance ships with two different side options, one is a solid side panel (Figure 17.1) and tile side panel (Figure 17.2). There are two of each and no left or right Securing Clip pins prior to use (Figures 17.3).
Discovery III D. Blower (Optional) C. Door Handle Assembly rear outer skin as shown in Figure 18.2. wall of appliance. Door Handle See Owner’s Manual for detailed operating instructions for CAUTION Shock Risk. • Do NOT remove grounding prong Fiber Handle from plug.
Discovery III Mobile Home Installation You must use a Quadra-Fire Outside Air Kit Part 10. Burn seasoned cord wood only. Other types OAK-ACC; which is available from you dealer, for of fuels may generate poisonous gases (e.g., installation in a mobile home.
Discovery III B. Accessories Service Parts DISCOVERY-III-C Beginning Manufacturing Date: Jan 2020 Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor. Hearth and Home Technologies does not sell directly to consumers. Stocked Provide model number and serial number when requesting service parts from your dealer at Depot...
Page 379
Hearth & Home Technologies 352 Mountain House Road Halifax, PA 17032 Division of HNI INDUSTRIES Please contact your Quadra-Fire dealer with any questions or concerns. For the number of your nearest Quadra-Fire dealer CAUTION DO NOT DISCARD THIS MANUAL •...
Page 380
Owner’s Manual Operation & Care INSTALLER: Leave this manual with party responsible for use and operation. OWNER: Retain this manual for future reference. Contact your dealer with questions on installation, operation, or service. NOTICE: DO NOT DISCARD THIS MANUAL WARNING If the information in these instructions is causing property damage, personal injury, DISCOVERY III WOOD APPLIANCE...
Page 381
Discovery III and Welcome to the Quadra-Fire Family NOTE: Clearances may only be reduced by means approved by the regulatory authority having jurisdiction A. Sample of Serial Number / Safety Label LOCATION: Back of appliance. HOT WHILE IN OPERATION DO NOT TOUCH, KEEP CHILDREN AND CLOTHING AWAY. CONTACT MAY CAUSE SKIN BURNS. KEEP FURNISHINGS AND OTHER CAUTION COMBUSTIBLE MATERIAL FAR AWAY FROM THE APPLIANCE.
Page 382
K. Negative Pressure......16 L. Frequently Asked Questions ....17 Quadra-Fire is a registered trademark of Hearth & Home Technologies. December 19, 2019...
Discovery III B. Warranty Policy Hearth & Home Technologies LIMITED LIFETIME WARRANTY Hearth & Home Technologies, on behalf of its hearth brands (“HHT”), extends the following warranty for HHT gas, wood, pellet and electric hearth appliances that are purchased from an HHT authorized dealer. WARRANTY COVERAGE: WARRANTY PERIOD: distributor, whichever occurs earlier.
Page 384
Discovery III WARRANTY CONDITIONS: • This warranty only covers HHT appliances that are purchased through an HHT authorized dealer or distributor. A list of HHT authorized dealers is available on the HHT branded websites. • • This warranty is only valid in the country in which the HHT authorized dealer or distributor that sold the appliance resides. •...
Page 385
Discovery III This warranty is void if: • • • There is any damage to the appliance or other components due to water or weather damage which is the result of, but not limited LIMITATIONS OF LIABILITY • have other rights, which vary from state to state. EXCEPT TO THE EXTENT PROVIDED BY LAW, HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY SPECIFIED HEREIN.
Discovery III C. Quick Start Guide NOTE: 10 Pieces of Newspaper, 10-20 Pieces of Dry ITEMS NEEDED FOR FIRST FIRE: OPEN AIR CONTROLS LOAD WOOD ADD NEWSPAPER HIGH BURN RATE CONTROL (Upper Right Corner) HIGH AUTOMATIC COMBUSTION CONTROL (ACC) (Middle right hand side) Warning! Risk of Fire.
Discovery III Listing and Code Approvals Model: Discovery III Wood Appliance Number: N/A Safety Laboratory: OMNI Test Laboratories, Inc. 1.6 grams per hour Emissions: Report No: 0061WS067S 80.2% Listed Room Appliance, Solid Type: Fuel Type **HHV Tested 74.2% UL 1482-11 (R2015) and ULC Standard: S627-00 and (UM) 84-HUD, Mobile ***EPA BTU Output: 12,200 to 36,800 / hr.
Discovery III WARNING This appliance is equipped with 5mm ceramic glass. Replace glass only with 5mm ceramic glass. Please contact your dealer for replacement glass. Fire Risk. Hearth & Home Technologies disclaims any responsibility for, and the warranty will be D.
Roaring, rumbling noises has been placed on the burning of wood for home heating. Loud cracking or banging sounds In order to improve the situation, we at Quadra-Fire Metal warping have developed cleaner-burning wood appliances that surpass the requirements for emissions established by our governing agencies.
Discovery III 2. Second Stage D. Air Controls The next stage of burning, the secondary stage, is the high and low based on desired heat output, installation maintained and not allowed to go out. This will ensure 1. Burn Rate Air Control it is set too low for your burning conditions.
Discovery III E. Using Burn Rate Air Control & ACC System CAUTION Injury Risk. • Gloves recommended 1. Start up and Reloading Fuel Open both Burn Rate Air Control and ACC systems fully. To do this with the Burn Rate Air Controls push spring handle up to high.
Page 392
Discovery III WARNING This wood appliance has a manufacturer-set minimum Risk of Fire. low burn rate that must not be altered. It is against federal When set on High Burn Rate and over-riding regulations to alter this setting or otherwise operate this the Automatic Combustion Control system an wood appliance in a manner inconsistent with operating instructions in this manual.
Discovery III G. Building A Fire NOTE: • • Do NOT use grates, andirons or other methods to NOTE: The special high temperature paint that your support fuel. It will adversely affect emissions. appliance heats. You will notice an odor and WARNING perhaps see some vapor rise from the appliance surface;...
H. Blower Operating Instructions I. Opacity (Smoke) This is the measure of how cleanly your appliance is NOTE: If your Quadra-Fire wood appliance is equipped burning. Opacity is measured in percent; 100% opacity is with an optional blower, you should follow...
Discovery III J. Clear Space K. Negative Pressure NOTE: Do NOT place combustible objects within 4 ft WARNING (1.2 m) of the front of appliance (Figure 16.1). Asphyxiation Risk. • Mantel: • Negative pressure can cause spillage Avoid placing candles and other heat-sensitive objects of combustion fumes, soot and on mantel or hearth.
Discovery III L. Frequently Asked Questions ISSUES SOLUTIONS Odor from appliance caused by the curing of the paint and the burning off of any oils remaining from manufacturing. Noise is caused by metal expanding and contracting as it heats up and cools down, similar to Metallic noise the sound produced by a furnace or heating duct.
Discovery III Maintenance and Service A. Quick Reference Maintenance Guide CAUTION! you many years of trouble-free service. Contact your Allow the appliance to completely cool down before dealer to answer questions regarding proper operation, performing any cleaning or maintenance. Start the troubleshooting and service for your appliance.
Discovery III 2. Cleaning Plated Surfaces B. General Maintenance • Frequency: Prior to first burn and then as desired 1. Creosote (Chimney) Cleaning • By: Homeowner • Frequency: Every 2 months during heating season or BEFORE frequently if chimney exceeds or is under 14-16 ft. (measured from bottom of appliance) cause permanent markings on the plating.
Page 399
Discovery III INCORRECT POSITIONS adhering to its surface. over the glass and the smokey, relatively cool condition of a Operating the appliance with the Burn Rate Air Control and Start-Up Air Control all the way open for 30-45 minutes should remove the built up coating. WARNING Fire Risk.
Discovery III Troubleshooting Guide With proper installation, operation, and maintenance your wood appliance will provide years of trouble-free service. If problem and the corrective action to be taken. Start Fire Problems Possible Cause Solution Not enough kindling/paper or no Use dry kindling, more paper. Arrange kindling & kindling/paper wood for air movement.
NOTE: DO NOT OVER TIGHTEN RETAINERS - can cause glass to break. 9. Replace the door on the appliance. Quadra-Fire appliances are equipped with ceramic super heat-resistant glass, which can only be broken by impact or misuse. WARNING Figure 22.1...
Discovery III C. Snap Disc D. Door Handle Assembly Service Part: SRV230-0470 Service Part: SRV7033-071 1. Locate the snap disc bracket assembly at the bottom left 1. Slide door handle through door. rear corner of the appliance. 2. Install additional washer(s) as shown in Figure 23.2. 2.
Page 403
Discovery III Service Part: SRV7033-209 Figure 24.1). 3. Remove the ceramic blanket (Figure 24.2). resting on all tubes (Figure 24.3 and Figure 24.4). (Figure 24.2 and Figure 24.4) Figure 24.3 and Figure 24.4). Baffle Board even with front tube & resting on all tubes Burn Rate Air Control...
Discovery III F. Decorative Side Panel Side Panel Service Part: SRV7037-027 Tile Frame Service Part: SRV7033-324 Frame Blank Service Part: SRV7033-346 Your appliance ships with two different side options, one is a solid side panel (Figure 25.1) and tile side panel (Figure 25.2).
Discovery III G. Tube Channel Assembly Service Part: SRV7033-023 Removing Tube Channel Assembly NOTE: Service Space 1. Remove the right side shield by removing 2 screws in In order to replace the tube channel assembly a the back using a Phillips head screw driver. clearance of 19 inches (483mm) is required on the right 2.
Discovery III B. Exploded View DISCOVERY-III-C Service Parts Beginning Manufacturing Date: Jan 2020 Wood Stove Ending Manufacturing Date: Active Part number list on following page. 12/19 December 19, 2019 7037-804A...
Page 411
Discovery III C. Service Parts DISCOVERY-III-C Service Parts Beginning Manufacturing Date: Jan 2020 Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION . Parts must be ordered from a dealer or Stocked Hearth and Home Technologies does not sell directly to consumers distributor.
Page 412
Key, Cam Latch SRV430-1151 15.6 Nut, Locking Door Handle Pkg of 24 226-0100/24 Pedestal Assembly SRV7037-025 Logo, Quadra-Fire Pkg of 10 7000-649/10 Pedelstal Base SRV7037-029 Rear Cover, Pedelstal SRV7037-152 Additional service part numbers appear on following page. December 19, 2019...
Page 413
Discovery III DISCOVERY-III-C Service Parts Beginning Manufacturing Date: Jan 2020 Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor. Hearth and Home Technologies does not sell directly to consumers. Stocked Provide model number and serial number when requesting service parts from your dealer at Depot or distributor.
Discovery III D. Accessories DISCOVERY-III-C Service Parts Beginning Manufacturing Date: Jan 2020 Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor. Hearth and Home Technologies does not sell directly to consumers. Stocked Provide model number and serial number when requesting service parts from your dealer at Depot...
Page 415
Hearth & Home Technologies 352 Mountain House Road Halifax, PA 17032 Division of HNI INDUSTRIES Please contact your Quadra-Fire dealer with any questions or concerns. For the number of your nearest Quadra-Fire dealer CAUTION DO NOT DISCARD THIS MANUAL •...
APPAREIL AU BOIS SÉRIE 4300 CONTRÔLE AUTOMATIQUE DE LA COMBUSTION (ACC) • Ne pas entreposer ni utiliser de l'essence ou d'autres MODÈLE : • – Si l'appareil de chauffage 43M-ACC-C 43ST-ACC-C • AVERTISSEMENT SURFACES CHAUDES ! • • • •...
Page 417
Appareil au bois série 4300 ACC • DANGER! • AVERTISSEMENT! • ATTENTION! • AVIS : TABLE DES MATIÈRES Installation de l’appareil cendres Par où commencer FC7037-801A 19 Decembre, 2019...
Page 418
Appareil au bois série 4300 ACC Modèle : N° et date du rapport : BTU/heure : Type : Taille du conduit : Norme : Avec Bois de corde sec REMARQUE : CAN/CSA-B365 au Canada 19 Decembre, 2019 FC7037-801A...
Page 419
Appareil au bois série 4300 ACC AVERTISSEMENT • • • • • • • • • • • Acier Brique Ardoise REMARQUE : Bois • Plastique • • ATTENTION Ce produit et les carburants utilisés pour faire fonctionner ce produit (bois), ainsi que les produits de combustion de ces carburants, peuvent vous exposer à...
Page 420
Appareil au bois série 4300 ACC Manuel de l’installateur Par où commencer d’installation • • • • – – ATTENTION • • AVERTISSEMENT AVERTISSEMENT • • • • AVIS : Les causes incluent : • • • • • • eau et autres appareils de chauffage •...
Page 421
Appareil au bois série 4300 ACC • • • • • Lisez toutes les instructions avant de commencer • • • • • • AVERTISSEMENT • • • • • • • Ne surchauffez PAS Pinces Des gants Divers vis et clous FC7037-801A 19 Decembre, 2019...
Page 422
Appareil au bois série 4300 ACC Step Top: AVERTISSEMENT • • • tire-fond tire-fond Support montage 19 Decembre, 2019 FC7037-801A...
Page 423
Appareil au bois série 4300 ACC ATTENTION INSTALLATEUR : manuel d’installation. Client : _______________________________________________________________________________________ Date d’installation : ____________________________________________________________________________ Lot/Adresse : _________________________________________________________________________________ Emplacement du foyer : ________________________________________________________________________ Installateur : __________________________________________________________________________________ Nº téléphone du détaillant/fournisseur : ___________________________________________________________ Nº de série : __________________________________________________________________________________ Modèle (encercler un) : AVERTISSEMENT! Risque d’incendie ou d’explosion ! Ne pas installer le foyer selon ces instructions peut mener à...
Page 424
Appareil au bois série 4300 ACC REMARQUE : MODÈLE MILLENNIUM 4300 À PIÉDESTAL 26-1/4 in [667mm] 3-5/8 in 13-1/8 in [92mm] [333mm] 6-3/4 in [170mm] 11 in [278mm] 30-1/2 in [773mm] 15-1/8 in [ 383mm] 21 in [533mm] 28-5/8 in [728mm] 26-3/8 in [668mm] 32-1/4 in [820mm]...
Page 425
Appareil au bois série 4300 ACC MODÈLE 4300 À DESSUS ÉTAGÉ ET À PIÉDESTAL 26 po (660mm) 26 po (660mm) 3-1/2 po 13 po [87mm] [330mm] 6-3/4 po [170mm] 11 po 11 po (278mm) (278mm) 34-1/4 po 34-1/4 po (868mm) (868mm) 15-1/8 po (383mm) 15-1/8 po (383mm)
Page 426
Appareil au bois série 4300 ACC MODÈLE Q ANNE 4300 À DESSUS ÉTAGÉ ET À PIEDS 26 po [660mm] 3-1/2 po 13 po [87mm] [330mm] 6-3/4 po [170mm] 11 po [278mm] 32-7/8 po [834mm] 15-1/8 po [383mm] 25 po [636mm] 28-5/8 po [728mm] 26-3/8 po [668mm] 34-1/8 po...
Page 427
Appareil au bois série 4300 ACC MODÈLE TRADITIONAL 4300 À DESSUS ÉTAGÉ ET À PIEDS 26 po [660mm] 3-1/2 po 13 po [87mm] [330mm] 6-3/4 po [170mm] 11 po [278mm] 32-7/8 po [834mm] 15-1/8 po [383mm] 23-3/8 po [595mm] 28-5/8 po [728mm] 26-3/8 po [668mm] 34-1/8 po [866mm]...
Page 428
Appareil au bois série 4300 ACC Au Canada PROTECTION CONTRE LES BRAISES : (Voir AVERTISSEMENT MODÈLE MILLENNIUM 31-5/8 po 31-5/8 po minimum minimum Dimensions du coussinet du coin avec un seul tuyau mural: 66-1/8 po 1730mm Porte de Porte de chargement chargement 41 po...
Page 429
Appareil au bois série 4300 ACC MODÈLE MONOBLOC À DESSUS ÉTAGÉ 31-5/8 po minimum Dimensions du coussinet du coin avec un seul tuyau mural: 41 po Porte de minimum chargement de 1440mm 54-3/4 po combustible 8 po 8 po 16 po 16 po 33-1/8 po 785mm...
Page 430
Appareil au bois série 4300 ACC DÉGAGEMENTS MINIMUMS PAR RAPPORT AUX MATÉRIAUX INFLAMMABLES en millimètre (pouces) Remarque : Les dimensions « A », « C » et « F » sont mesurées par rapport au centre de la buse. 4300 SERIES WOOD APPLIANCE (2020) INSTALATION : ENTIÈREMENT VERTICAL CONDUIT À...
Page 431
Appareil au bois série 4300 ACC • • • • Emplacement Emplacement Recommandé Recommandé Marginal Emplacement Endroit Qui N'Est Pas Recommandé Endroit Qui N'Est Pas Recommandé Vent De L'Air Extérieur Kit Sous le vent De Capuchon Multi-niveau des Toits FC7037-801A 19 Decembre, 2019...
Page 432
Appareil au bois série 4300 ACC AVIS : • • • Sorties ou retours de chauffage central • • • AVIS : • • • • • Moins de 305 cm (10 pi) 61 cm (2 pi) 91 cm (3 pi) 61 cm (2 pi) minimum 305 cm (10 pi) jusqu’à...
Page 433
Appareil au bois série 4300 ACC Chapeau de l’extrémité homologué Entretoise de toit (si nécessaire) Mitre Solin AVERTISSEMENT • Collier de garniture • sur le mur intérieur Cheminée • homologuée « T » isolé Carneau Support mural AVERTISSEMENT Gaine de conduit •...
Page 434
Appareil au bois série 4300 ACC Gaine de conduit Chapeau de l’extrémité homologué Mitre Composants • Solin • Cheminée • homologuée • • Support de plafond • Carneau • Instructions : Protection du sol plafond 343 mm (13,5 po) entre le dessous du plafond et le dessus de l’ouverture ou le dessus de l’ouverture est...
Page 435
Appareil au bois série 4300 ACC Carneau Boisseau de terre cuite avec espace d’air Cheminée en maçonnerie Col décoratif Entretoise murale Section de cheminée CAN/CSA-B365 avec un dégagement Bride murale de 51 mm (2 po) par pour attacher rapport aux matériaux inflammables la section de cheminée...
Appareil au bois série 4300 ACC Installation de l’appareil AVERTISSEMENT REMARQUE : • • Retirez et jetez ou une palette AVERTISSEMENT! VÉRIFIEZ LE JOINT D’ÉTANCHÉITÉ! • Enlevez 2 briques pour • l’installation, puis les réinstaller Retirer X8 Joint d’étanchéité Desser rer X4 Enlever et page 22)
Page 437
Appareil au bois série 4300 ACC Espaceur de l'élimination des cendres La porte se ferme au loquet lorsque la tige de la porte d’élimination des cendres est bloquée en place cendres (suite) Poignée Tige de la porte à cendres installée Finir l’installation du système de l’ARS page 23) ATTENTION!
Page 438
Appareil au bois série 4300 ACC Tiroir d’élimination des cendres Adaptateurs Couverture d’accès ARS Canal REMARQUE : Réinstallez les 2 briques avant dans la boîte à ou une palette AVERTISSEMENT! VÉRIFIEZ LE JOINT D’ÉTANCHÉITÉ! • • Plaque du couvercle 19 Decembre, 2019 FC7037-801A...
Page 439
Appareil au bois série 4300 ACC Alignez les trous supérieurs, répé- tez puis fixez Compartiment Posez l'appareil à plat d’élimination des sur son dos, sur une cendres surface protégée ou une palette. page 22) Supports de Vissez les 2 vis inférieures pieds sans les serrer Pieds de mise à...
Page 440
Appareil au bois série 4300 ACC ATTENTION! Traditional Installation de votre appareil Traditional sur pieds VÉRIFIEZ LES PANNEAUX DU DÉFLECTEUR ET LA LAINE CÉRAMIQUE ISOLANTE! • • REMARQUE : pieds ATTENTION • • REMARQUE : 19 Decembre, 2019 FC7037-801A...
Page 441
Appareil au bois série 4300 ACC AVERTISSEMENT REMARQUE : • • Adaptateur REMARQUE : l’extrémité Chapeau Pour l’installation section transversale au-sol Retirer Trou de la porte à défoncer dans la loquet cam base du piédestal. Conduit axe de poignée de porte flexible contre-écrou clé...
Page 442
Appareil au bois série 4300 ACC ATTENTION REMARQUE : • • • Ne placez PAS le cordon sous ou • MANUEL : A priorité sur le disque d’arrêt Support de MANUEL AUTO : Le disque d’arrêt VENTILATEUR VENTILATEUR ventilateur est avec aimant AUTO automatiquement...
Page 443
Appareil au bois série 4300 ACC ATTENTION Ne coupez PAS à travers : • • UL103 UL103 HT AVERTISSEMENT NORME CAN/ ULC-629M POUR CHEMINÉES PRÉFABRIQUÉES AVERTISSEMENT REMARQUE : Mechanical Code) NFPA 211 REMARQUE : Normes de FC7037-801A 19 Decembre, 2019...
Page 444
Appareil au bois série 4300 ACC Date of Service Performed By Description of Service 19 Decembre, 2019 FC7037-801A...
Page 445
Appareil au bois série 4300 ACC 43M-ACC-C Pièces de rechange Date de début de la fabrication: Jan 2020 IMPORTANT : CETTE INFORMATION N’EST PLUS À JOUR. Les pièces doivent être commandées Entreposé d’un détaillant ou d’un fournisseur. Hearth and Home Technologies ne vend pas directement aux consommateurs.
Page 446
SRV230-0470 Câblage (ventilateur) 7033-262 Ensemble des composants SRV7033-051 Amélioration, porte - Nickel (poignées nickel, tiges de charnières et logo) UK-DRNL Logo, Quadra-Fire, noir Pqt de 10 7000-649/10 pattes de fonte, noir ensemble de 4 TRAD-LEG-BK FIXATIONS Ensemble de réparation Avk Rivnut - outils Rivnut 1/4-20 et 3/8-16 RIVNUT-REPAIR Boulon, tête hexagonale, 1/4-20 X 1...
Page 447
352 Mountain House Road Halifax, PA 17032 Division of HNI INDUSTRIES Veuillez contacter votre fournisseur Quadra-Fire pour toute question. Pour obtenir le numéro de téléphone du distributeur Quadra-Fire le plus proche, ATTENTION NE PAS JETER CE MANUEL • Il contient •...
APPAREIL AU BOIS SÉRIE 4300 CONTRÔLE AUTOMATIQUE DE LA • Ne pas entreposer ni utiliser de l'essence ou d'autres COMBUSTION (ACC) • – Si l'appareil de chauffage MODÈLE : 43M-ACC-C • 43ST-ACC-C AVERTISSEMENT SURFACES CHAUDES ! • • • •...
Page 449
Poêle à bois série 4300 (ACC) REMARQUE : HOT WHILE IN OPERATION DO NOT TOUCH, KEEP CHILDREN AND CLOTHING AWAY. CONTACT MAY CAUSE SKIN BURNS. KEEP FURNISHINGS AND OTHER CAUTION COMBUSTIBLE MATERIAL FAR AWAY FROM THE APPLIANCE. SEE NAMEPLATE AND INSTRUCTIONS. CHAUD LORS DE L' O PÉRATION.
Page 450
Poêle à bois série 4300 (ACC) • DANGER! • AVERTISSEMENT! • ATTENTION! • AVIS : TABLE DES MATIÈRES Maintenance et entretien Homologations et codes approuvés 8 Guide de dépannage Remplacement des pièces de rechange 19 Decembre, 2019 FC7037-802A...
Poêle à bois série 4300 (ACC) Hearth & Home Technologies GARANTIE À VIE LIMITÉE Hearth & Home Technologies, au nom de ses marques (« HHT »), étend la garantie suivante aux appareils HHT au gaz, bois, granulés, et électrique achetés d’un détaillant HHT autorisé. COUVERTURE DE LA GARANTIE : HHT garantit au propriétaire d’origine de l’appareil, sur le site d’installation d’origine, ainsi qu’à...
Poêle à bois série 4300 (ACC) CONDITIONS DE LA GARANTIE : approuvés est disponible sur les sites Web des produits HHT. a fourni le produit à l’origine. d’expédition des pièces ne sont pas couverts par cette garantie. de réduction de particules (tel que mesuré par une procédure d’essai approuvé) au cours des 36 mois qui suivent la date d’achat, le Temps total écoulé...
Page 453
Poêle à bois série 4300 (ACC) ’appareil est soumis à de longues périodes de l’humidité ou de la condensation. le résultat d’, mais non limité à, une mauvaise de la cheminée ou de ventilation de l’installation. expresse ou implicite, ou d’un contrat, d’un délit ou autre, doit être limitée au remplacement, à la réparation ou au rembourse- 4021-645J •...
Page 454
Poêle à bois série 4300 (ACC) REMARQUE : ÉLÉMENTS NÉCESSAIRES d’allumage et quelques morceaux de bois bien séchés. POUR LE PREMIER FEU : OUVREZ LES AJOUTEZ DU BOIS AJOUTEZ DU JOURNAL ENTRÉES D’AIR ÉLEVÉ CONTRÔLE DU TAUX DE COMBUSTION (coin supérieur droit) ÉLEVÉ...
Poêle à bois série 4300 (ACC) Homologations et codes approuvés Modèle : 80,2 % Sécurité : 74,2 % N° et date du ***EPA, Sortie en BTU : rapport : Type : Taille du conduit : Norme : Recommandé Longueur De Avec Bois de corde sec REMARQUE : FC7037-802A...
Page 456
Poêle à bois série 4300 (ACC) AVERTISSEMENT • • • • • • • • • • Ne surchauffez PAS • REMARQUE ATTENTION Ce produit et les carburants utilisés pour faire fonctionner ce produit (bois), ainsi que les produits de combustion de ces carburants, peuvent vous exposer à...
Page 457
Poêle à bois série 4300 (ACC) AVERTISSEMENT • • • • • • • • • • • • • • • • FC7037-802A 19 Decembre, 2019...
Page 458
Poêle à bois série 4300 (ACC) (ACC) Réglage de ÉLEVÉ l’air de combustion MOYEN DÉMARRAGE AIR AR- (ÉLEVÉ) RIÈRE Réglage de l’air à l’allumage 19 Decembre, 2019 FC7037-802A...
Poêle à bois série 4300 (ACC) Commande manuelle de la minuterie système ACC ATTENTION • Arrêt manuel de la Réglage de ÉLEVÉ minuterie Tirez vers l’air de (ACC) l’avant pour combustion MOYEN arrêter Réglage de l’air à l’allumage chaleur FC7037-802A 19 Decembre, 2019...
Page 460
Poêle à bois série 4300 (ACC) AVERTISSEMENT • MISE EN MARCHE (Figure ARRIÈRE (ÉLEVÉ) REMARQUE : Si vous utilisez le ventilateur refoulant optionnel REMARQUE : REMARQUE : 19 Decembre, 2019 FC7037-802A...
Page 461
Poêle à bois série 4300 (ACC) REMARQUE : • • REMARQUE : AVERTISSEMENT • • • • Le panneau du déflecteur doit être à niveau avec le tube avant et reposer sur tous les tubes. Réglage de l’air de combustion Réglage de l’air à...
Page 462
Poêle à bois série 4300 (ACC) REMARQUE : AVERTISSEMENT • • • AVERTISSEMENT • • • • Emplacement du disque d’arrêt ATTENTION MANUEL : A priorité sur le disque OUVREZ LES FENÊTRES PENDANT LA COMBUSTION d’arrêt INITIALE POUR DISSIPER LA FUMÉE ET LES ODEURS ! MANUAL •...
Page 463
Poêle à bois série 4300 (ACC) REMARQUE : AVERTISSEMENT • • • AVERTISSEMENT Les causes incluent : • • • eau et autres appareils de chauffage • • • • Fuites du conduit Maintain 4 ft (1.22m) clearance to combustible in front of appliance •...
Page 464
Poêle à bois série 4300 (ACC) PROBLÈMES SOLUTIONS Bruit du ventilateur de convection CONTACTEZ VOTRE DÉTAILLANT AVERTISSEMENT AVERTISSEMENT • • • • • • • 19 Decembre, 2019 FC7037-802A...
Poêle à bois série 4300 (ACC) Maintenance et entretien ATTENTION • • • FRÉQUENCE TÂCHE Back of Firebox Ceramic Blanket Baffle Retainer Bracket Après chaque corde de bois Baffle Board Ventilateur de convection en option Après toutes les quatre cordes de bois Système de cheminée la suie et le créosote tous les deux mois pendant l’hiver ou plus souvent si la...
Page 466
Poêle à bois série 4300 (ACC) AVERTISSEMENT • • • • Soulevez la grille et inspectez le dessus de la porte pour Élimination de la créosote présente dans la cheminée • Fréquence : • Par : ATTENTION • • Inspection : 19 Decembre, 2019 FC7037-802A...
Page 467
Poêle à bois série 4300 (ACC) Formation de dépôt et nettoyage : Jeter les cendres • Fréquence : • Par : AVERTISSEMENT • AVERTISSEMENT • • • • • Nettoyage de la vitre AVERTISSEMENT • Fréquence : • Par : •...
Page 468
Poêle à bois série 4300 (ACC) POSITIONS INCORRECTES laine céramique isolante AVERTISSEMENT • • • • ATTENTION • POSITIONS CORRECTES Arrière de la Laine céramique Arrière de la boîte à feu Laine céramique boîte à feu isolante Support retenant isolante le déflecteur Panneau de déflecteur...
Poêle à bois série 4300 (ACC) Remplacement des pièces de rechange Service: SRV230-0470 Service: SRV7000-012 Snap Disc REMARQUE : Magnet Spade Connectors AVERTISSEMENT • • ATTENTION Glass Assembly Pendant le nettoyage de la vitre : • • • • • •...
Page 471
Poêle à bois série 4300 (ACC) 4300 Millénaire Pour Le Service De La Partie : SRV7037-003 4300 Étape De Service Supérieure De La Partie : SRV7037-012 Placement Dimensions Qté Requis Placement Dimensions Qté Requis FC7037-802A 19 Decembre, 2019...
Page 472
Poêle à bois série 4300 (ACC) ATTENTION 4300 Millénaire et 4300 Étape de Service Supérieure de la 4300 Étape De Service Supérieure De La Partie: SRV7033-071 Partie: 832-0540 section transversale de la porte loquet cam axe de poignée de porte Un dégagement de 51 mm (2 po) est nécessaire entre le coude de la tige de...
Page 473
Poêle à bois série 4300 (ACC) Service: SRV7037-112 Le panneau du déflecteur doit être à niveau avec le tube avant et reposer sur tous les tubes. Réglage de l’air de combustion Réglage de l’air à l’allumage Laine céramique au-dessus Tubes profilés Panneau de déflecteur en 2 mcx FC7037-802A 19 Decembre, 2019...
Page 474
Poêle à bois série 4300 (ACC) REMARQUE : REMARQUE Slide one gasket over each tube Channel Tube Channel Rack Channel Cover Access Screws (4) Cover Remove 2 Screws Channel Nuts (2) Tube Channel Assembly Side Panel 19 Decembre, 2019 FC7037-802A...
Page 475
Poêle à bois série 4300 (ACC) Date de service Interprété par Discription du service FC7037-802A 19 Decembre, 2019...
Page 476
Poêle à bois série 4300 (ACC) Date de service Interprété par Discription du service 19 Decembre, 2019 FC7037-802A...
Page 477
Poêle à bois série 4300 (ACC) 43M-ACC-C Pièces de rechange Poêle à bois Date de début de la fabrication: Jan 2020 La liste des pièces de rechange se trouve à la page suivante. 12/19 FC7037-802A 19 Decembre, 2019...
Page 478
Poêle à bois série 4300 (ACC) 43M-ACC-C Pièces de rechange Date de début de la fabrication: Jan 2020 IMPORTANT : CETTE INFORMATION N’EST PLUS À JOUR. Les pièces doivent être commandées d’un détaillant ou d’un fournisseur. Hearth and Home Technologies ne vend pas directement Entreposé...
Page 479
Ensemble de composants (poignées à ressort dorées Nickel 436-5360 de (1) 13 mm (1/2 po) et (2) 6 mm (1/4 po), (2) tiges de 436-5350 charnière dorées, logo Quadra-Fire Ensemble de poignée de porte SRV7033-071 13.7 Poignée de porte, Fibre SRV7060-212 13.8...
Page 480
Poêle à bois série 4300 (ACC) 43M-ACC-C Pièces de rechange Date de début de la fabrication: Jan 2020 IMPORTANT : CETTE INFORMATION N’EST PLUS À JOUR. Les pièces doivent être commandées Entreposé d’un détaillant ou d’un fournisseur. Hearth and Home Technologies ne vend pas directement aux consommateurs.
Page 481
Poêle à bois série 4300 (ACC) 43M-ACC-C Pièces de rechange Date de début de la fabrication: Jan 2020 IMPORTANT : CETTE INFORMATION N’EST PLUS À JOUR. Les pièces doivent être commandées Entreposé d’un détaillant ou d’un fournisseur. Hearth and Home Technologies ne vend pas directement aux consommateurs.
Page 482
Poêle à bois série 4300 (ACC) 43ST-ACC-C Pièces de rechange Date de début de la fabrication : Jan 2020 Modèle haut de gamme - Poêle à bois La liste des pièces de rechange se trouve à la page suivante. 12/19 19 Decembre, 2019 FC7037-802A...
Page 483
Poêle à bois série 4300 (ACC) 43ST-ACC-C Pièces de rechange Date de début de la fabrication : Jan 2020 IMPORTANT : CETTE INFORMATION N’EST PLUS À JOUR. Les pièces doivent être commandées d’un détaillant ou d’un fournisseur. Hearth and Home Technologies ne vend pas directement aux consommateurs. Entreposé...
Page 484
Poêle à bois série 4300 (ACC) 43ST-ACC-C Pièces de rechange Date de début de la fabrication : Jan 2020 IMPORTANT : CETTE INFORMATION N’EST PLUS À JOUR. Les pièces doivent être commandées d’un détaillant ou d’un fournisseur. Hearth and Home Technologies ne vend pas directement Entreposé...
Page 485
Poêle à bois série 4300 (ACC) 43ST-ACC-C Pièces de rechange Date de début de la fabrication : Jan 2020 IMPORTANT : CETTE INFORMATION N’EST PLUS À JOUR. Les pièces doivent être commandées d’un détaillant ou d’un fournisseur. Hearth and Home Technologies ne vend pas directement Entreposé...
Page 486
Poêle à bois série 4300 (ACC) 43ST-ACC-C Pièces de rechange Date de début de la fabrication : Jan 2020 IMPORTANT : CETTE INFORMATION N’EST PLUS À JOUR. Les pièces doivent être commandées d’un détaillant ou d’un fournisseur. Hearth and Home Technologies ne vend pas directement Entreposé...
Page 487
Poêle à bois série 4300 (ACC) 43ST-ACC-C Pièces de rechange Date de début de la fabrication : Jan 2020 IMPORTANT : CETTE INFORMATION N’EST PLUS À JOUR. Les pièces doivent être commandées d’un détaillant ou d’un fournisseur. Hearth and Home Technologies ne vend pas directement Entreposé...
Page 488
SRV230-0470 Câblage (ventilateur) 7033-262 Ensemble des composants SRV7033-051 Amélioration, porte - Nickel (poignées nickel, tiges de charnières et logo) UK-DRNL Logo, Quadra-Fire, noir Pqt de 10 7000-649/10 pattes de fonte, noir ensemble de 4 TRAD-LEG-BK FIXATIONS Ensemble de réparation Avk Rivnut - outils Rivnut 1/4-20 et 3/8-16 RIVNUT-REPAIR Boulon, tête hexagonale, 1/4-20 X 1...
Page 489
352 Mountain House Road Halifax, PA 17032 Division of HNI INDUSTRIES Veuillez contacter votre fournisseur Quadra-Fire pour toute question. Pour obtenir le numéro de téléphone du distributeur Quadra-Fire le plus proche, ATTENTION NE PAS JETER CE MANUEL • Il contient •...
Page 490
Manuel d’installation Installation et mise en place de l’appareil AVIS : NE PAS JETER CE MANUEL AVERTISSEMENT Le non-respect de ces instructions peut APPAREIL AU BOIS DISCOVERY III CONTRÔLE AUTOMATIQUE DE LA COMBUSTION (ACC) • Ne pas entreposer ni utiliser de l'essence ou d'autres MODÈLE : •...
Page 491
Discovery III • • • • TABLE DES MATIÈRES ..12 ......3 .
Page 492
Discovery III Modèle : Appareil au bois Discovery III 80,2 % N° et date du 74,2 % rapport : Type : BTU/heure : Taille du conduit : Norme : maisons mobiles. Avec Bois de corde sec dans le carburant. de Douglas de bois de dimensions. REMARQUE : CAN/CSA-B365 au Canada.
Page 493
Discovery III AVERTISSEMENT • • • suivants : double paroi. • • • • • • • • Ne chauffez PAS de trop Acier Pour obtenir une assistance ou des renseignements Brique ou votre fournisseur. Tuiles REMARQUE : Verre Ardoise •...
Page 494
Discovery III Manuel de l’installateur Par où commencer d’installation Tenir compte de : • • • Du volume de circulation • leur entretien. des braises incandescentes. traversera le plafond et le toit. – – Avisez les pompiers. fonctionnement. ATTENTION AVERTISSEMENT •...
Page 495
Discovery III • • inspectez pour tout dommage. • • les besoins de tous les appareils de combustion et de • Lisez toutes les instructions avant de commencer • • • • • • AVERTISSEMENT soin de ne pas endommager le produit. suivants : •...
Page 496
Discovery III ATTENTION INSTALLATEUR : manuel d’installation. Client : _______________________________________________________________________________________ Date d’installation : ____________________________________________________________________________ Lot/Adresse : _________________________________________________________________________________ Emplacement du foyer : ________________________________________________________________________ Installateur : __________________________________________________________________________________ Nº téléphone du détaillant/fournisseur : ___________________________________________________________ Nº de série : __________________________________________________________________________________ Modèle (encercler un) : AVERTISSEMENT! Risque d’incendie ou d’explosion ! Ne pas installer le foyer selon ces instructions peut mener à...
Page 497
Discovery III REMARQUE : 673 mm (26-1/2 po) 337 mm (13-1/4 po) 278 mm 89 mm (11 po) (3-1/2 po) 170 mm 975 mm (6-3/4 po) (38-3/8 po) 337 mm (13-1/4 po) 384 mm (15-1/8 po) 454 mm (17-7/8 po) 692 mm (27-1/4 po) 728 mm (28-5/8 po) 668 mm (26-5/16 po)
Page 498
Discovery III Au Canada PROTECTION CONTRE LES BRAISES : chargement du combustible. Ouvrez la porte et mesurez une AVERTISSEMENT 31-5/8 po 31-5/8 po minimum minimum Dimensions du coussinet du coin avec un seul tuyau mural: Porte de Porte de 66-1/8 po 1730mm chargement chargement...
Page 499
Discovery III DÉGAGEMENTS MINIMUMS PAR RAPPORT AUX MATÉRIAUX INFLAMMABLES en millimètre (pouces) Remarque : Les dimensions « A », « C » et « F » sont mesurées par rapport au centre de la buse. DISCOVERY III WOOD APPLIANCE (2020) INSTALATION : ENTIÈREMENT VERTICAL CONDUIT À...
Page 500
Discovery III • les solins du plafond et du grenier ainsi que les chevrons. • • • Traversez le toit dans sa partie la plus haute. Cela minimise Emplacement Emplacement Recommandé Recommandé Marginal Emplacement Endroit Qui N'Est Pas Recommandé Endroit Qui N'Est Pas Recommandé...
Page 501
Discovery III AVIS : Suivez les instructions du fabricant en ce qui concerne les • • Sorties ou retours de chauffage central • • • • AVIS : • • • tire et causer une faible performance. conditions de vent peuvent affecter les performances de la •...
Page 502
Discovery III Chapeau de compromettre les performances. l’extrémité homologué Entretoise de toit (si nécessaire) Mitre Solin AVERTISSEMENT Collier de garniture • Cheminée homologuée sur le mur intérieur « T » isolé • • Carneau Support mural AVERTISSEMENT Gaine de conduit •...
Page 503
Discovery III Gaine de conduit Chapeau de l’extrémité homologué Composants Mitre • Solin • Cheminée • homologuée • • Support de plafond • Carneau minimum. • Instructions : Protection du sol minimum plafond 343 mm (13,5 po) entre le dessous du plafond et le dessus de l’ouverture ou le dessus de l’ouverture est Minimum 46 cm...
Page 504
Discovery III Carneau Fire Clay Flue Liner with Airspace Masonry buse, utilisez 3 vis autotaraudeuses. Vous devez observer les Chimney Trim Collar Au Canada, si on souhaite traverser une paroi ou une cloison en Wall Spacer Chimney Section CAN/CSA-B365. with 2 inch Wall Band to (51mm) Secure Chimney...
Page 505
Discovery III Installation de l’appareil AVERTISSEMENT • • grenier ou garage. • • odeurs. • • AVERTISSEMENT • Mèches et scies pour percer des trous dans le mur ou le sol de votre maison. Instructions d’installation • Des feuilles Installation au sol et à l’arrière : •...
Page 506
Discovery III Pince de moment. fixation • bas au besoin) REMARQUE : Utilisez uniquement une peinture haute NE PAS Empilez les tuiles incombustibles dans le cadre, comme il est AVERTISSEMENT incombustibles. 19 Decembre, 2019 FC7037-803A...
Page 507
Discovery III Alignez les trous de la bride de montage du ventilateur avec Remettez et serrez les boulons pour installer le ventilateur Poignée de porte Voir le pour obtenir des instructions ATTENTION • Poignée en fibre • • Ne placez PAS le cordon sous ou devant •...
Page 508
Discovery III au moyen de boulons. ATTENTION DOIT ÊTRE MAINTENUE. Ne coupez PAS à travers : • entretoises du plafond. • une maison mobile. AVERTISSEMENT sol. REMARQUE : Mechanical Code) WARNING sont permis tant que la longueur horizontale Do Not use single wall connector pipe anywhere in a mobile home installation.
Page 509
Discovery III Date of Service Performed By Description of Service FC7037-803A 19 Decembre, 2019...
Page 510
Discovery III DISCOVERY-III-C Pièces de rechange Date de début de la fabrication : Jan 2020 IMPORTANT : CETTE INFORMATION N’EST PLUS À JOUR. Les pièces doivent être commandées d’un détaillant ou d’un fournisseur. Hearth and Home Technologies ne vend pas directement Entreposé...
Page 511
352 Mountain House Road Halifax, PA 17032 Division of HNI INDUSTRIES Veuillez contacter votre fournisseur Quadra-Fire pour toute question. Pour obtenir le numéro de téléphone du distributeur Quadra-Fire le plus proche, ATTENTION NE PAS JETER CE MANUEL • Il contient •...
Page 512
Manuel du propriétaire Entretien et utilisation Communiquez avec votre détaillant pour les questions concernant l’installation, l’utilisation, ou l'entretien. AVIS : NE PAS JETER CE MANUEL AVERTISSEMENT Le non-respect de ces instructions peut entraîner des dommages matériels, des APPAREIL AU BOIS DISCOVERY III CONTRÔLE AUTOMATIQUE DE LA •...
Page 513
Discovery III REMARQUE : HOT WHILE IN OPERATION DO NOT TOUCH, KEEP CHILDREN AND CLOTHING AWAY. CONTACT MAY CAUSE SKIN BURNS. KEEP FURNISHINGS AND OTHER CAUTION COMBUSTIBLE MATERIAL FAR AWAY FROM THE APPLIANCE. SEE NAMEPLATE AND INSTRUCTIONS. CHAUD LORS DE L' O PÉRATION. NE PAS TOUCHER. GARDEZ LES ENFANTS ET LES VÊTEMENTS LOIN DE L' E SPACE DÉSIGNÉ DE L' I NSTALLATION. LE CONTACT PEUT CAUSER DES ATTENTION: BRÛLURES À...
Page 514
Discovery III • DANGER ! • AVERTISSEMENT ! Indique une situation dangereuse pouvant entraîner la mort ou des blessures graves si elle n’est • ATTENTION ! • AVIS : TABLE DES MATIÈRES Maintenance et entretien ..2 B.
Page 515
Discovery III Hearth & Home Technologies GARANTIE À VIE LIMITÉE Hearth & Home Technologies, au nom de ses marques (« HHT »), étend la garantie suivante aux appareils HHT au gaz, bois, granulés, et électrique achetés d’un détaillant HHT autorisé. COUVERTURE DE LA GARANTIE : HHT garantit au propriétaire d’origine de l’appareil, sur le site d’installation d’origine, ainsi qu’à...
Page 516
Discovery III CONDITIONS DE LA GARANTIE : approuvés est disponible sur les sites Web des produits HHT. a fourni le produit à l’origine. d’expédition des pièces ne sont pas couverts par cette garantie. de réduction de particules (tel que mesuré par une procédure d’essai approuvé) au cours des 36 mois qui suivent la date d’achat, le Temps total écoulé...
Page 517
Discovery III ’appareil est soumis à de longues périodes de l’humidité ou de la condensation. le résultat d’, mais non limité à, une mauvaise de la cheminée ou de ventilation de l’installation. expresse ou implicite, ou d’un contrat, d’un délit ou autre, doit être limitée au remplacement, à la réparation ou au rembourse- 4021-645J •...
Page 518
Discovery III REMARQUE : ÉLÉMENTS NÉCESSAIRES d’allumage et quelques morceaux de bois bien séchés. POUR LE PREMIER FEU : OUVREZ LES AJOUTEZ DU BOIS AJOUTEZ DU JOURNAL ENTRÉES D’AIR ÉLEVÉ CONTRÔLE DU TAUX DE COMBUSTION (coin supérieur droit) ÉLEVÉ CONTRÔLE AUTOMATIQUE DE LA COMBUSTION (ACC) (au centre à...
Page 519
Discovery III Homologations et codes approuvés Modèle : Appareil au bois Discovery III Sécurité : 80,2 % N° et date du 74,2 % rapport : ***EPA, Sortie en BTU : Type : Taille du conduit : Norme : maisons mobiles. Recommandé...
Page 520
Discovery III AVERTISSEMENT • • • • • Home Technologies. maison mobile doit être maintenue. • • • • • Ne surchauffez PAS – si l’appareil ou le carneau devient • rouge, le feu est trop intense. d’incendie. Pour obtenir une assistance ou des renseignements ou votre fournisseur.
Page 521
Discovery III AVERTISSEMENT entièrement sec, même si sa surface est sèche. • • Trop remplir de bois • bois de rebut • absorber l’eau de pluie ou la neige fondue, ce qui retarde son Un ou plusieurs des symptômes suivants peuvent indiquer une Des bruits de rugissement ou de grondement Des forts bruits de craquelure ou de claquement appareils au bois, tout comme les autres appareils, doivent être...
Page 522
Discovery III le charbon reste. Il s’agit de la phase de combustion la plus (ACC) Pour engager le système de minuterie du contrôle de couleur bleue. Il est très important de recharger l’appareil alors qu’il contient encore assez de charbon chaud pour fournir la chaleur Utilisez cette fonction lors du rechargement de combustible nouveau bois repose sur du charbon chaud.
Page 523
Discovery III système ACC ATTENTION • chaleur Commande manuelle de la minuterie Réglage de l’air de combustion ÉLEVÉ MOYEN ÉLEVÉ MOYEN Réglage Réglage élevé Contrôle automatique de la combustion (ACC) Arrêt manuel de la minuterie (commande Tirez vers automatique de combustion) l’avant pour arrêter FC7037-804A...
Page 524
Discovery III AVERTISSEMENT vous annulez l’action du contrôle automatique de • annulera votre garantie. bas. REMARQUE : Si vous utilisez le ventilateur refoulant optionnel remis du combustible. REMARQUE : REMARQUE : 19 Decembre, 2019 FC7037-804A...
Page 525
Discovery III REMARQUE : • • REMARQUE : durcir pendant que l’appareil chauffe. Vous AVERTISSEMENT ce qui est normal. Nous recommandons dissipe et que la peinture soit durcie. • • de vidage des cendres. • Si la porte de l’appareil est ouverte. •...
Page 526
Discovery III REMARQUE : d’un ventilateur refoulant en option, suivez les AVERTISSEMENT • • • AVERTISSEMENT l’appareil. • • • Éloignez tous ces liquides de l’appareil quand il est en marche. Emplacement du disque d’arrêt • ATTENTION MANUEL : A priorité...
Page 527
Discovery III REMARQUE : AVERTISSEMENT • • de carbone. • besoin d’un bon tirage. AVERTISSEMENT Les causes incluent : • • Hottes d’aspiration pour cuisinières • eau et autres appareils de chauffage • • au système de climatisation • • Trappe d’accès au grenier Fuites du conduit Maintain 4 ft (1.22m) clearance to...
Page 528
Discovery III PROBLÈMES SOLUTIONS Odeur provenant de l’appareil fabrication. Bruit du ventilateur de convection augmente. CONTACTEZ VOTRE DÉTAILLANT AVERTISSEMENT AVERTISSEMENT • l’appareil. • • • • • Éloignez tous ces liquides de l’appareil quand il est en marche. • 19 Decembre, 2019 FC7037-804A...
Page 529
Discovery III Maintenance et entretien ATTENTION • nettoyage ou d’effectuer l’entretien. • d’entretien. • FRÉQUENCE TÂCHE Back of Firebox Ceramic Blanket Baffle Retainer Bracket Après chaque corde de bois Baffle Board Ventilateur de convection en option Après toutes les quatre cordes de bois Système de cheminée la suie et le créosote tous les deux mois pendant l’hiver ou plus souvent si la...
Page 530
Discovery III • Fréquence : Avant le premier emploi et puis ensuite selon Élimination de la créosote présente dans la cheminée les besoins • Fréquence : Tous les 2 mois pendant la saison de chauffage • Par : ou selon la recommandation d’une entreprise de ramonage AVANT d’allumer l’appareil pour la première fois.
Page 531
Discovery III POSITIONS INCORRECTES combustion et de l’allumage. laine céramique isolante AVERTISSEMENT couvert par la garantie. Utilisez l’appareil au bois place. • • • • un mauvais rendement Arrière de la Laine céramique boîte à feu isolante ATTENTION prudence au moment de remettre du bois dans le poêle pour •...
Page 532
Discovery III Guide de dépannage Solution Utilisez du petit bois sec, plus de papier. Disposez le petit l’air. s’alimente Ouvrez une fenêtre sous l’appareil en direction du vent. des feuilles dans le chapeau de Ouvrez une fenêtre sous l’appareil en direction du vent. un surtirage.
Discovery III Pièces de rechange Service : SRV7037-003 Service : 7000-012 toucher. cendres. vos mains. Posez la porte face vers le bas sur une table ou surface de avec un aspirateur. Placez les briques du fond de l’appareil. Remettez les arrêtoirs de vitre. Faites attention de ne pas Installez les briques arrière sur les briques du fond.
Page 534
Discovery III Service : SRV230-0470 Service : SRV7033-071 d’arrêt. doit pouvoir bouger librement. rectangulaires vers le haut pour les sortir du support comme Enlevez les 2 vis du disque d’arrêt au moyen d’un tournevis ATTENTION Repoussez le disque d’arrêt et les cosses rectangulaires dans pouvoir bouger librement.
Page 535
Discovery III Service : SRV7037-112 Le panneau du déflecteur doit être à niveau avec le tube avant et reposer sur tous les tubes. Réglage de l’air de combustion Réglage de l’air à l’allumage Laine céramique au-dessus Tubes profilés Panneau de déflecteur en 2 mcx FC7037-804A 19 Decembre, 2019...
Page 536
Discovery III Panneau Latéral Service De La Partie : SRV7037-027 Tuile Cadre De Services De La Partie : SRV7033-324 Cadre Vierge De Service : SRV7033-346 moment. Retrait du panneau latéral complet ATTENTION Utilisez uniquement une peinture haute NE PAS Installation du panneau latéral à tuiles soulevant et le retirant de l’appareil le retrait du panneau latéral complet).
Page 537
Discovery III Service : SRV7033-023 Enlevez les 4 vis du couvercle d’accès au canal et enlevez le couvercle. Si un tel espace n’est pas disponible, l’appareil devra tubes. remplacement des tubes. REMARQUE : de les enlever. support de l’ensemble, en commençant par le trou arrière. Slide one gasket Lift up to over each tube...
Page 538
Discovery III Date de service Interprété par Discription du service 19 Decembre, 2019 FC7037-804A...
Page 539
Discovery III Date de service Interprété par Discription du service FC7037-804A 19 Decembre, 2019...
Page 540
Discovery III Date de service Interprété par Discription du service 19 Decembre, 2019 FC7037-804A...
Page 541
Discovery III Date de service Interprété par Discription du service FC7037-804A 19 Decembre, 2019...
Page 542
Discovery III DISCOVERY-III-C Pièces de rechange Date de début de la fabrication : Jan 2020 Poêle à Bois La liste des pièces de rechange se trouve à la page suivante. 12/19 19 Decembre, 2019 FC7037-804A...
Page 543
Discovery III DISCOVERY-III-C Pièces de rechange Date de début de la fabrication : Jan 2020 IMPORTANT : CETTE INFORMATION N’EST PLUS À JOUR. Les pièces doivent être commandées d’un détaillant ou d’un fournisseur. Hearth and Home Technologies ne vend pas directement Entreposé...
Page 544
Discovery III DISCOVERY-III-C Pièces de rechange Date de début de la fabrication : Jan 2020 IMPORTANT : CETTE INFORMATION N’EST PLUS À JOUR. Les pièces doivent être commandées d’un détaillant ou d’un fournisseur. Hearth and Home Technologies ne vend pas directement Entreposé...
Page 545
Discovery III DISCOVERY-III-C Pièces de rechange Date de début de la fabrication : Jan 2020 IMPORTANT : CETTE INFORMATION N’EST PLUS À JOUR. Les pièces doivent être commandées d’un détaillant ou d’un fournisseur. Hearth and Home Technologies ne vend pas directement Entreposé...
Page 546
Discovery III DISCOVERY-III-C Pièces de rechange Date de début de la fabrication : Jan 2020 IMPORTANT : CETTE INFORMATION N’EST PLUS À JOUR. Les pièces doivent être commandées d’un détaillant ou d’un fournisseur. Hearth and Home Technologies ne vend pas directement Entreposé...
Page 547
352 Mountain House Road Halifax, PA 17032 Division of HNI INDUSTRIES Veuillez contacter votre fournisseur Quadra-Fire pour toute question. Pour obtenir le numéro de téléphone du distributeur Quadra-Fire le plus proche, ATTENTION NE PAS JETER CE MANUEL • Il contient •...
Page 548
TABLE OF CONTENTS 2 J-2000 Features 3 Before You Begin 3 Check Calibration 4 Set Species 5 Species Code Chart 6 Set Temperature 7 Set Pin Calibration 7 Taking a Reading 8 Information About Your Readings 8 To Check Accumulated Readings 8 To Reset Meter 9 Care of Your Meter 10 Service For Your Meter...
Page 549
D E L M H O R S T J - 2 0 0 0 #2497A-100 contact pins with 5/16” penetration & Connector for External Electrode Digital Readout Temperature Key Read Key Calibration Species Key Check Key J-2000 FEATURES Resistance technology recognized worldwide as the most accurate method for measuring wood MC 6% to 40% MC wood (Douglas Fir ref) 6% to 60% MC wood (J-2000/X)
BEFORE YOU BEGIN Key Functions READ KEY - Press to read the %MC. CALIBRATION CHECK KEY - This key, (when pressed with the read key) checks the meter calibration. It also displays the number of readings in memory (up to 100), the aver- age, and the highest stored reading.
When the battery is removed and then reconnected, the meter displays its software version for one second and then turns itself off. After replacing the battery, you must reset the meter as described in Resetting the Meter section. A hard Reset is required if, after changing the battery, the display is frozen.
To scroll forward through the species list hold the species while the current species code is displayed and scroll to the species number desired. To scroll backward through the species list, press and release the species key . Within one second, press and hold the temperature key .
SET TEMPERATURE The J-2000 defaults to a temperature of 70ºF. As wood temperature increases, its electrical resistance decreases and indicated moisture content rises. Lower wood temperatures result in lower indicated moisture content. A correction is necessary if the wood temperature is outside the range of 50ºF (10ºC) to 90ºF (32ºC).
SET PIN CALIBRATION The basic factory calibration of the J-2000 is for use with non-insulated pins. Insulated pins read lower than non-insu- lated ones. The difference is small below 10% MC but increases as the moisture content increases above 10%. When using an electrode with insulated pins, such as the 26- ES hammer electrode, you can change the calibration to compensate for this difference.
INFORMATION ABOUT YOUR READINGS Readings below 6% will be displayed as a numeric value, (-##.#), but will not be added to the accumulated readings in memory. Readings below 6% due to temperature and species adjustments will be shown as a numeric value with no minus sign.
CARE OF YOUR METER To keep your meter in good working order: Store your meter in a clean, dry place. The protective carrying case provided is an ideal storage place when the meter is not in use. Change the 9-Volt battery as needed. Use only EverReady or Duracell brand batteries.
SERVICE FOR YOUR METER If your meter is not working properly, replace the battery with a new one and check the calibration. If this does not resolve the problem please send your meter back to Delmhorst for repair. Go to HYPERLINK "http://www.delmhorst.com" www.delmhorst.com and click on Support and then download the Return Form.
WARRANTY Delmhorst Instrument Co., referred to hereafter as Delmhorst, guarantees its J-2000 meter for one year from date of purchase and any optional electrodes against defects in material or workmanship for 90 days. If, within the warranty period, you find any defect in material or workmanship return the meter following the instructions in the Service for Your Meter section.
Page 561
or more than 65 years Delmhorst Instrument has been the leading manufacturer of high quality, US-made moisture meters and thermo-hygrometers. Today we offer a wide range of meters for applications including water damage restoration, construction, flooring, lumber/woodworking, paper, and agriculture. ®...
Page 563
Dry Gas Meter Calibration Meter Manufacturer: Apex Model: XC-50-DIR Lab ID #: Serial #: 1906005 Calibration Date: 11/7/2019 Calibration Expiration: 5/7/2020 Barometric Pressure: 30.05 in. Hg Reference Standard DGM Unit Under Test Previous Calibration Manufacturer: Apex Date γ Factor: Model: SK25DA 0.998 Lab ID#: 47 Allowable Deviation (±5%):...
Page 564
Pressure Gauge Calibration Work Sheet Gauge Manufacturer: Apex Maximum Range (inH Instrument ID #: 129 (dH) Calibration Date: 11/12/2019 Calibration Expiration: 11/12/2020 Barometric Pressure: 30.16 in. Hg Reference Standard Gauge Manufacturer: Dwyer Model: 477AV-1 Instrument ID#: 136 Calibration Expiration Date: 9/27/2020 Reference Gauge Pressure Gauge Difference...
Page 565
Pressure Gauge Calibration Work Sheet Gauge Manufacturer: Apex Maximum Range (inH Instrument ID #: 129 (dP) Calibration Date: 11/12/2019 Calibration Expiration: 11/12/2020 Barometric Pressure: 30.16 in. Hg Reference Standard Gauge Manufacturer: Dwyer Model: 475 Instrument ID#: 76 Calibration Expiration Date: 3/14/2020 Reference Gauge Pressure Gauge Difference...
Page 566
Emissions Sampling System Thermocouple Calibration Check Calibration based on NIST Monograph 175 per ASTM E2515-11 All thermocouples are type “K” Date: 7/26/2019 Sampling System ID Numbers: 129/130 Performed By: S. Button Calibration Instrument ID Number: Thermocouple Location Reference Acceptable Temperature Error (F) Catalyst Flue...
Page 567
Dry Gas Meter Calibration Meter Manufacturer: Apex Model: XC-50-DIR Lab ID #: Serial #: 1906006 Calibration Date: 11/7/2019 Calibration Expiration: 5/7/2020 Barometric Pressure: 30.05 in. Hg Reference Standard DGM Unit Under Test Previous Calibration Manufacturer: Apex Date γ Factor: Model: SK25DA 1.000 Lab ID#: 47 Allowable Deviation (±5%):...
Page 568
Pressure Gauge Calibration Work Sheet Gauge Manufacturer: Apex Maximum Range (inH Instrument ID #: 130 (dH) Calibration Date: 11/12/2019 Calibration Expiration: 11/12/2020 Barometric Pressure: 30.16 in. Hg Reference Standard Gauge Manufacturer: Dwyer Model: 477AV-1 Instrument ID#: 136 Calibration Expiration Date: 9/27/2020 Reference Gauge Pressure Gauge Difference...
Page 569
Pressure Gauge Calibration Work Sheet Gauge Manufacturer: Apex Maximum Range (inH Instrument ID #: 130 (dP) Calibration Date: 11/12/2019 Calibration Expiration: 11/12/2020 Barometric Pressure: 30.16 in. Hg Reference Standard Gauge Manufacturer: Dwyer Model: 475-000 Instrument ID#: 76 Calibration Expiration Date: 3/14/2020 Reference Gauge Pressure Gauge Difference...
PRESSURE FLUID LEVEL Microtector Gage ® Precision Pressure Measurement On indication of contact, the operator stops The Microtector ® Gage combines the time- lowering the point and reads the micrometer proven principles of the Hook Gage type which indicates one half the applied pressure. manometer and modern solid-state integrat- By interpolating eight divisions (each being ed circuit electronics.
After making contact, turn the point out of the Fluid Level fluid by turning the micrometer barrel counter- Level the gage by adjusting the two front lev- clockwise to a reading of .010 or more. Again, eling screws (Item 8 on drawing) until the bub- watch the meter and, this time, lower the ble in the spirit level is centered in the small point by turning the micrometer barrel.
When the readings are complete, the pres- (2) If the meter operation continues to be sure should be removed and the zero setting sluggish, replace the size AA, 1.5 volt battery. of Microtector ® Gage rechecked. Any change (Replace the battery at least once a year to in the zero position will indicate inaccurate avoid deterioration of battery and damage to readings.