Viewing RMON Events Log Using the CLI Commands
The following table summarizes the equivalent CLI commands for viewing fields displayed
in the RMON Events Log page.
CLI Command
rmon table-size log
entries
show rmon log [event]
The following is an example of the CLI commands:
Console (config)# rmon table-size log 500
Console# show rmon log
Maximum table size: 500
Event DescriptionTime
------------------------------------
1ErrorsJan 18 2002 23:48:19
1ErrorsJan 18 2002 23:58:17
2High BroadcastJan 18 2002 23:59:48
Console# show rmon log
Maximum table size: 500 (800 after reset)
Event DescriptionTime
------------------------------------
1ErrorsJan 18 2002 23:48:19
1ErrorsJan 18 2002 23:58:17
2High BroadcastJan 18 2002 23:59:48

Defining Device Alarms

The RMON Alarm page allows network administrators to set network alarms. Network
alarms occur when a network problem is detected. Rising and falling thresholds generate
alarms. To open the RMON Alarm page:
Description
Configures maximum number of log table entries.
Displays the RMON logging table.
View ing Statistics