DC charging pile . Our products will bring you better charging services and safer charging guarantees. Scope of application This manual is applicable to the use of TS-EDW series electric vehicle wall-mounted DC charging piles . In order to facilitate your proficient operation and use of this product...
Teison Energy Technology Co., Ltd. Safety Tips ⚫ This safety notice is applicable to all operations of the TS-EDW series electric vehicle intelligent AC charging pile. Before installing and debugging the charger, you should read this instruction manual carefully. The instruction manual contains important information that is conducive to the normal operation of the equipment and avoids incorrect operation.
Page 4
⚫ The equipment can only be repaired by Teison Energy's after-sales department or certified and authorized personnel. These personnel should be fully familiar with the warnings and correct operating procedures in this...
Page 5
instruction manual. ⚫ Any defective component must be replaced with an identical component. hint ⚫ Please place this manual in a conspicuous place near the equipment to ensure that operators can easily read it. ⚫ Before installing and debugging the charging pile, please be sure to carefully read the safety rules and warnings, as well as all warning signs posted on the equipment.
1、Overview 1.1. Product Introduction TS-EDW series electric vehicle wall-mounted DC charging piles (hereinafter referred to as charging piles) are designed in accordance with UL 2202 and other American standard charging piles; they are suitable for installation in home parking lots,...
Page 8
(2)Flexible interaction: The device is equipped with a 10-inch LCD display, supports three-point simultaneous touch, and responds sensitively and accurately; (3)Real-time display: The display screen displays the device operating status and charging process information in real time, including but not limited to: charging voltage, charging current, charging power, charging temperature, SOC, charging amount, faults and alarms;...
1.3. Usage Environment Table 1.1. Equipment working environment Seri project index unit Remark numb Operating temperature - 3 0~5 0 ℃ Storage temperature -40~70 ℃ Protection level Type 3R Work ≤90% ﹣ Relative condensatio humidity store ≤95% ﹣ Derating for use Altitude ≤2000 above 2000...
≥0.99 Power Factor ≤0.1% Standby power consumption Output voltage regulation ≤±0.5% accuracy Output current accuracy ≤±1% Harmonic current ≤4% noise ≤65dB Mechanical behavior Galvanized steel shell material cooling method Forced air cooling Gun Line Human-computer interaction Display size 10 inches Display Material brightness 450cd/m²...
1.6. POS machine introduction (optional) Teison Energy Payment System consists of two major sections: Software: My Teison APP can complete payment by scanning the QR code on the display of the charging device. Currently supported payment methods include: Stripe, PayPal, Cybersource,...
Page 12
NAYAX supports the following payment methods: Visa, Mastercard, Apple Pay, Google Pay, Samsung Pay; Wizar POS supports the following payment methods: Arab BANK; Choose one of the two methods. If the user's location supports the above payment methods, you can use the Teison Energy payment system.
After troubleshooting, reset the emergency stop button before resuming charging. ( Note: The emergency stop button is only allowed to be pressed in abnormal situations. Do not press the emergency stop button at will under normal charging conditions! ) Teison Energy's charging equipment meets...
performance requirements; the equipment dynamically adjusts charging parameters according to the data provided by the electric vehicle battery management system (BMS) to complete the charging process. The charging pile touch screen can display the main charging parameters, battery parameters, fault information, etc., with obvious status indications and text prompts to prevent personnel from misoperation.
Page 15
etc., with complete protection functions, including short circuit protection, input overvoltage/undervoltage, input overcurrent, output overvoltage/undervoltage, output overcurrent, output overtemperature, etc. At the same time, during the charging process, key data such as total charging voltage, total charging current, battery temperature, etc. can be monitored and protected in real time.
mechanical lock or electronic lock is not reliably locked, charging will not be started before charging and charging will be stopped during charging. 2.2.2. Protection logic Conservation Protection Logic Project Real-time detection of working voltage. When the device is in Output overvoltage state, an alarm will be issued and the output will overvoltage...
Page 17
and the output is stopped. Communicate with the platform in real time. When the platform communication is disconnected, the device will alarm.
3、Equipment operating instructions 3.1. Start charging 3.1.1. First start Before starting the equipment for the first time after installation, the following checks should be performed: 1) Are there any loose or missing screws in the equipment cabinet ? 2) Are there any loose or missing wires in the equipment cabinet ? 3) There is damage to the wireless skin in the equipment cabinet;...
3)Confirm whether the controller, display screen, and light strip are on; if not all are on, turn off the power and check the circuits of the unlit parts. Repeat the above steps after troubleshooting. If the above steps are normal, the power-on verification process is completed.
Page 20
Indicator light Indicator Color Indicator status name Power light Yellow Light Long bright Charging light Green Light Flash Fault light red light Table 3.1.2.2. Indicator light charging status If the red light is on, it means that the equipment is faulty. At this time, you need to turn off the power and check the equipment, eliminate the fault and power it on again.
charging 3.1.3. Normal shutdown operation When you need to shut down normally, click the "Stop" button on the screen and select the corresponding end method (such as swiping a card). The green light stops flashing and you can then unplug the charging gun and reset it. Before unplugging the charging gun, please check whether the indicator light meets the following table: Indicator light...
quickly, you can press the emergency stop button of the device. At this time, the device will quickly cut off the output and the indicator light status is as follows: Indicator light Indicator Color Indicator status name Power light Yellow Light Charging light Green Light Fault light...
Page 23
leaving the factory. It is not recommended to modify the configuration without special requirements. 1)After successfully powering on, press the emergency stop button and check whether the display shows the following status. If not, it means that the communication between the screen and the main control board is abnormal.
Page 24
3) After entering the settings, users can view and modify general settings, network settings, OCPP settings, device information and records. 4) Enter the general settings, which are divided into system settings, user preferences, charging station configuration and charging connector configuration. System settings include brightness adjustment, full screen display and language setting configuration, as shown in the figure below.
Page 25
5) User preferences include password settings and four charging modes (of which POS machine is a non-standard option). When the "anonymous billing" function is enabled, the other charging modes are not available. 6) Charging station configurations include plug-and-play and load balancing (non-standard options).
Page 26
7) Charging connector configuration allows you to set the maximum power, maximum voltage, minimum voltage, QR code, whether to enable Base64 encoded QR code, and the billing price per kWh. 8) OCPP settings include “OCPP start button”, “OCPP platform ID”, “charging station ID” and whether basic authentication is enabled for the “OCPP start button”.
Page 27
9) After the settings are completed, click the OCPP start button. Return to the main interface to check if there is a cloud icon. 10) Check the current software version of the device through "Device Information".
Page 28
11) "Record Information" allows you to view charging information and logs (may need to contact technical support or obtain through OCPP). Delete Record will delete all charging records.
4、Equipment structure and installation 4.1. Equipment appearance and dimensions The structural dimensions of a 20-40kW single-gun charging pile are shown in the figure: The structural dimensions of a 40kW dual-gun charging pile are shown in the figure:...
4.2. Installation Instructions The torque of the equipment grounding bolt can be referred to the following table: The conductor of the equipment incoming line segment should meet the following requirements: AC power Serial supply Recommended cable Wire power Remark number rated input type diameter...
Page 32
other requirements: 1、The permanent connectors, casing and other metal conductors of the equipment must be well grounded. based on the size of the DC charging pile and the required 2、 installation distance between the charging piles. 3. Draw lines on the ground according to the drawings, both horizontally and vertically.
Page 33
with a crane; 7. Align the charging pile with the expansion screw hole and lower it, install the 0-12 flat washer and spring washer, and then lock it. 8. Connect the corresponding cables correctly and the installation is complete. Note: Only qualified professionals are allowed to perform the installation and commissioning process!
5、Equipment packaging, transportation and storage 5.1. Packaging The packaging should take into account the requirements of moisture-proof, dust-proof and shock-proof; all parts are shipped together inside the pile; the pile body is covered with a plastic bag, supported by foam all around, and packaged in a foam carton outside;...
equipment are all treated with rust prevention, but they should still be protected from direct sunlight and rain erosion during transportation. 5.3. Storage If the product is not used immediately after purchase and needs to be stored for a short or long term, it is recommended to store the equipment in a clean, dry, well-ventilated indoor place at 5℃...
3.2*3.2mm; The warning label is affixed to the device casing. 5.4.3.FCC label 5.5.FCC explain FCC regulatory conformance: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation.
Page 37
with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
Page 38
IC regulatory conformance: This device complies with CAN ICES (A)/NMB (A). This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada's licence-exempt RSS(s). Operation is subject to the following two conditions: (1) This device may not cause interference. (2) This device must accept any interference, including interference that may cause undesired operation of the device.
Page 39
should be installed and operated with minimum distance of 20 cm between the radiator and your body. This transmitter must not be collocated or operating in conjunction with any other antenna or transmitter. Cet equipement est conforme aux limites d’ exposition aux rayonnements de la IC etablies pour unenvironnement non controe.
Need help?
Do you have a question about the TS-EDW Series and is the answer not in the manual?
Questions and answers