Copeland XEV20D Reference Manual

Stepper valve actuator

Advertisement

Quick Links

XEV20D
Stepper Valve Actuator
Contents
1 General Warnings.......................................................................................................................................... 2
2 General Description ...................................................................................................................................... 2
3 Absolute Maximum Power.......................................................................................................................... 3
4 Wiring Diagram .............................................................................................................................................. 3
4.1
One Valve Configuration ...........................................................................................................................3
4.2
Two Valves Configuration ........................................................................................................................4
4.3
iPro Connections ..........................................................................................................................................4
5 Valve Connections ........................................................................................................................................ 5
6 Serial Line - CanBus ...................................................................................................................................... 6
7 LEDs Meaning................................................................................................................................................. 7
8 Technical Data................................................................................................................................................ 8
026-4283 R1
©2024 Copeland LP.
REFERENCE GUIDE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the XEV20D and is the answer not in the manual?

Questions and answers

Summary of Contents for Copeland XEV20D

  • Page 1: Table Of Contents

    4 Wiring Diagram .............................. 3 One Valve Configuration ...........................3 Two Valves Configuration ........................4 iPro Connections ............................4 5 Valve Connections ............................5 6 Serial Line - CanBus ............................6 7 LEDs Meaning..............................7 8 Technical Data..............................8 026-4283 R1 ©2024 Copeland LP.
  • Page 2: General Warnings

    • 2 configurable valve outputs to drive bipolar or unipolar valves • Pb1/Pb2 configurable analog inputs: NTC/PTC/Pt1000 • Pb3/Pb4 configurable analog inputs: 4 to20mA/0 to5V/Pt1000 • CanBus serial line • LAN to communicate with instrument of the same series or devices of i-CHILL200CX series 026-4283 R1 ©2024 Copeland LP.
  • Page 3: Absolute Maximum Power

    Current 0.9A max > TF20D Current 0.9A max for each valve > TF40D Valve Type Unipolar Valves (5-6 wires) Current 0.33A max > TF20D Current 0.33A max for each valve > TF20D Wiring Diagram One Valve Configuration 026-4283 R1 ©2024 Copeland LP.
  • Page 4: Two Valves Configuration

    Two Valves Configuration iPro Connections 026-4283 R1 ©2024 Copeland LP.
  • Page 5: Valve Connections

    Green White Green Green 5 - Common ---- ---- ---- ---- 5-6 WIRES VALVES (UNIPOLAR) Connection Numbering SPORLAN SAGINOMIYA Orange Orange Yellow Yellow Black Black 5 - Common Gray Gray Figure 5-1 - XEV20D Device 026-4283 R1 ©2024 Copeland LP.
  • Page 6: Serial Line - Canbus

    CanBus CanBus par_1 CanBus Number CanBus Number CanBus Number CanBus Number Number Number CAN node par_2 address par_3 EVV_StepsOutput EVV_ProbeTConfiguration EVV_Temperature EVV_ValvePosition I/O 1 EEV_OutRateValve 1 Valve 1 Valve 1 Valve 1 Valve 1 026-4283 R1 ©2024 Copeland LP.
  • Page 7: Leds Meaning

    Valve 1 is closing CLOSE V1 Valve 1 completely closed OPEN V2 Blinking Valve 2 is opening OPEN V2 Valve 2 completely opened CLOSE V2 Blinking Valve 2 is closing CLOSE V2 Valve 2 completely closed 026-4283 R1 ©2024 Copeland LP.
  • Page 8: Technical Data

    The contents of this publication are presented for informational purposes only and they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. Copeland reserves the right to modify the designs or specifications of such products at any time without notice.

Table of Contents