Advertisement

Quick Links

Installation & Usage Guide

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Netron RDM6D and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for OBSIDIAN CONTROL SYSTEMS Netron RDM6D

  • Page 1 Installation & Usage Guide...
  • Page 2 ©2024 OBSIDIAN CONTROL SYSTEMS all rights reserved. Information, specifications, diagrams, images, and instructions herein are subject to change without notice. Obsidian Control Systems logo and identifying product names and numbers herein are trademarks of ADJ PRODUCTS LLC. Copyright protection claimed includes all forms and matters of copyrightable materials and information now allowed by statutory or judicial law or hereinafter granted.
  • Page 3: Table Of Contents

    C O N T E N T S GENERAL INFORMATION LIMITED WARRANTY SAFETY GUIDELINES OVERVIEW INSTALLATION INSTRUCTIONS CONNECTIONS EMERGENCY CUE REMOTE DEVICE MANAGEMENT (RDM) MAINTENANCE SPECIFICATIONS | FCC STATEMENT DIMENSIONS...
  • Page 4: General Information

    G E N E R A L I N F O R M AT I O N FOR PROFESSIONAL USE ONLY INTRODUCTION Please read and understand the instructions in this manual carefully and thoroughly before attempting to operate this device. These instructions contain important safety and use information. UNPACKING Every device has been thoroughly tested and has been shipped in perfect operating condition.
  • Page 5: Limited Warranty

    (including negligence), misrepresentation, strict liability, breach of warranty of Elation or Obsidian Control Systems or any supplier, and even if Elation or Obsidian Control Systems or any supplier has been advised of the possibility of such damages.
  • Page 6: Safety Guidelines

    This device is a sophisticated piece of electronic equipment. To guarantee a smooth operation, it is important to follow all instructions and guidelines in this manual. OBSIDIAN CONTROL SYSTEMS is not responsible for injury and/or damages resulting from the misuse of this device due to the disregard of the information printed in this manual.
  • Page 7: Overview

    O V E R V I E W The Netron RDM6D is a powerful DIN Rail or Wall Mount DMX/RDM splitter with six wire terminal or RJ45 outputs. Designed with rugged, opto-isolated outputs it is the ideal device for permanent installations requiring a compact design and flexible wiring options.
  • Page 8: Installation Instructions

    I N S TA L L AT I O N I N S T R U C T I O N S DISCONNECT POWER BEFORE PERFORMING ANY MAINTENANCE! ELECTRICAL CONNECTIONS A qualified electrician should be used for all electrical connections and/or installations. USE CAUTION WHEN POWER LINKING OTHER MODEL DEVICES AS THE POWER CONSUMPTION OF OTHER MODEL DEVICES MAY EXCEED THE MAXIMUM POWER OUTPUT OF THIS DEVICE.
  • Page 9: Top Connections

    Damage resulting from incorrect connection is not covered under warranty. The Netron RDM6D offers versatile power options, supporting a DC input range of 9-45V at 2A for permanent installations. Additionally, it can be temporarily powered using any USB-C adapter or battery pack, which is particularly useful during setup or configuration phases.
  • Page 10: Front Connections

    CONNECTI ON S FRONT CONNECTIONS • 6-port DMX connection plate (RJ45 or Terminal Block) or Cover Plate • 2-port DMX In / Thru connection plate (RJ45 or Terminal Block) or Cover Plate Cover Plate (shown) Mode Button Terminate Button Power Active LED Emergency Test Button...
  • Page 11 C O N N EC TI O N S EMERGENCY TEST BUTTON The UL924 certified Emergency Cue system of the NETRON RDM6D serves as a critical feature for safety and compliance, activating a pre-programmed emergency lighting state designed to ensure visibility and aid in evacuation during power failures or other emergencies, as per UL924 standards.
  • Page 12: Bottom Connections

    C O N N EC TI O N S BOTTOM CONNECTIONS • 6-port DMX connection plate (RJ45 or Terminal Block) or Cover Plate • Emergency Contact (3pin Terminal Block, Dry Contact or 12V). Set Normally Open or Normally Closed with the DIP Switch #2 on the top. Phoenix-3P Connector Cover Plate (shown), or DMX connection plate...
  • Page 13 CONNEC TI O NS FRONT & BOTTOM CONNECTION PLATES To install either the Terminal Connection Plate or the RJ45 DMX Plates, begin by loosening the thumbscrews that secure the currently installed Connection Plate. After loosening, unplug any connected cables and carefully remove the existing plate. Then, install the replacement Connection Plate and secure it with the provided thumbscrews.
  • Page 14 C O N N EC TI O N S TOP & FRONT CONNECTION PLATES To install either the RJ45 DMX Plate or the Cover Plate, first loosen the thumbscrews securing the currently installed Connection Plate and Cover Plate. After loosening, unplug any connected cables and carefully remove the plate.
  • Page 15: Emergency Cue

    E M E R G E N C Y C U E The UL924 certified Emergency Cue system of the NETRON RDM6D serves as a critical feature for safety and compliance, activating a pre-programmed emergency lighting state designed to ensure visibility and aid in evacuation during power failures or other emergencies, as per UL924 standards.
  • Page 16 E M E R G E N C Y C U E The action for the emergency cue is set All On independently for each output port. Configure All 512 DMX channels are set to 255 this setting within the menu of the corresponding output port.
  • Page 17: Remote Device Management (Rdm)

    R E M O T E D E V I C E M A N A G E M E N T ( R D M ) NOTE: In order for RDM to work properly, RDM enabled equipment must be used throughout the entire system, including DMX data splitters and wireless systems.
  • Page 18: Maintenance

    M A I N T E N A N C E The Obsidian Control Systems NETRON RDM6D is designed as rugged, roadworthy device. The only required service is occasional cleaning. For other service-related concerns, please contact your Obsidian Control Systems dealer, or visit www.obsidiancontrol.com.
  • Page 19 S P E C I F I C AT I O N S Mounting: DIN Rail Wall-mount Connections: Front: 6-port DMX connection plate (RJ45 or Terminal Block) or Cover Plate 2-port DMX In / Thru connection plate (RJ45 or Terminal Block) or Cover Plate Top: 2-port DMX In / Thru connection plate (RJ45 or Terminal Block) or Cover Plate DC In (2pin Terminal Block)
  • Page 20: Dimensions

    D I M E N S I O N S Drawings not to scale 7.1in. [180mm] 2.7in. [67mm] 2.1in. [54mm] 1.7in. [44mm]...
  • Page 22 Guide d'installation et d'utilisation...
  • Page 23 Le logo Obsidian Control Systems et les noms et numéros de produits d’identification figurant dans ce document sont des marques commerciales d’ADJ PRODUCTS LLC. La protection du droit d’auteur revendiquée comprend toutes les formes et matières de matériel et d’informations protégés par le droit d’auteur...
  • Page 24 C O N T E N T S INFORMATIONS GÉNÉRALES GARANTIE LIMITÉE DIRECTIVES DE SÉCURITÉ VUE D’ENSEMBLE INSTRUCTIONS D’INSTALLATION CONNEXIONS INDICATEUR D’URGENCE GESTION DES APPAREILS À DISTANCE (RDM) MAINTENANCE | DÉCLARATION DE LA FCC SPÉCIFICATIONS DIMENSIONS...
  • Page 25: Informations Générales

    INFORMATIONS GÉNÉRALES POUR USAGE PROFESSIONNEL UNIQUEMENT INTRODUCTION Veuillez lire attentivement et comprendre les instructions contenues dans ce manuel avant d’essayer d’utiliser cet appareil. Ces instructions contiennent des informations importantes sur la sécurité et l’utilisation. DÉBALLAGE Chaque appareil a été soigneusement testé et a été expédié en parfait état de fonctionnement. Vérifiez soigneusement le carton d’expédition pour déceler tout dommage éventuel survenu pendant le transport.
  • Page 26: Garantie Limitée

    (y compris la négligence), de fausse déclaration, de responsabilité stricte, de violation de garantie d’Elation ou d’Obsidian Control Systems ou de tout fournisseur, et même si Elation ou Obsidian Control Systems ou tout fournisseur a été informé de la possibilité de tels dommages.
  • Page 27: Directives De Sécurité

    Cet appareil est un équipement électronique sophistiqué. Pour garantir un fonctionnement sans problème, il est important de suivre toutes les instructions et directives de ce manuel. OBSIDIAN CONTROL SYSTEMS n’est pas responsable des blessures et/ou dommages résultant d’une mauvaise utilisation de cet appareil en raison du non- respect des informations imprimées dans ce manuel.
  • Page 28: Vue D'ensemble

    V U E D ’ E N S E M B L E Le Netron RDM6D est un puissant répartiteur DMX/RDM sur rail DIN ou à montage mural avec six sorties à bornes ou RJ45. Conçu avec des sorties robustes et opto-isolées, c’est l’appareil idéal pour les installations permanentes nécessitant une conception compacte et des options de câblage flexibles.
  • Page 29: Instructions D'installation

    I N S T R U C T I O N S D ’ I N S TA L L AT I O N DÉBRANCHEZ L’ALIMENTATION AVANT D’EFFECTUER TOUTE OPÉRATION D’ENTRETIEN ! CONNEXIONS ELECTRIQUES Un électricien qualifié doit être utilisé pour tous les raccordements et/ou installations électriques.
  • Page 30 C O N N E X I O N S CONNEXION D’ALIMENTATION CC Le système de contrôle Obsidian NETRON RDM6D est évalué à 9-48 V CC. Ne le connectez pas à une alimentation en dehors de cette plage. Les dommages résultant d’une connexion incorrecte ne sont pas couverts par la garantie.
  • Page 31 C O N N E X I O N S CONNEXIONS AVANT Plaque de connexion DMX à 6 ports (RJ45 ou borne) ou plaque de couverture Plaque de connexion DMX dans 2 ports (RJ45 ou borne) ou plaque de couverture Plaque de recouvrement (illustrée) Bouton de mode Bouton Terminer...
  • Page 32 C O N N E X I O N S BOUTON DE TEST D’URGENCE Le système de signalisation d’urgence certifié UL924 du NETRON RDM6D constitue une fonction essentielle de sécurité et de conformité, activant un état d’éclairage d’urgence préprogrammé conçu pour assurer la visibilité...
  • Page 33 C O N N E X I O N S CONNEXIONS CÔTÉ INFÉRIEUR Plaque de connexion DMX à 6 ports (RJ45 ou borne) ou plaque de couverture Contact d’urgence (bornier à 3 broches, contact sec ou 12 V). Réglez normalement ouvert ou normalement fermé...
  • Page 34: Connexions

    C O N N EX I O N S PLAQUES DE CONNEXION AVANT ET INFÉRIEURE Pour installer la plaque de connexion du terminal ou les plaques DMX RJ45, commencez par desserrer les vis à oreilles qui fixent la plaque de connexion actuellement installée. Après avoir desserré, débranchez tous les câbles connectés et retirez soigneusement la plaque existante.
  • Page 35 C ON N EX I O N S PLAQUES DE CONNEXION SUPÉRIEURES ET AVANT Pour installer la plaque DMX RJ45 ou la plaque de recouvrement, desserrez d’abord les vis à oreilles qui fixent la plaque de connexion et la plaque de recouvrement actuellement installées. Après avoir desserré, débranchez tous les câbles connectés et retirez soigneusement la plaque.
  • Page 36: Indicateur D'urgence

    I N D I C AT E U R D ’ U R G E N C E Le système de signalisation d’urgence certifié UL924 du NETRON RDM6D constitue une fonction essentielle de sécurité et de conformité, activant un état d’éclairage d’urgence préprogrammé conçu pour assurer la visibilité...
  • Page 37 I N D I C AT E U R D ’ U R G E N C E À L’ARRÊT Signal d’urgence L’action signal d’urgence définie Tout activé indépendamment pour chaque port de sortie. Tous les 512 canaux DMX sont réglés sur 255 Configurez ce paramètre dans le menu du port de sortie correspondant.
  • Page 38: Gestion Des Appareils À Distance (Rdm)

    G E S T I O N D E S A P PA R E I L S À D I S TA N C E ( R D M ) REMARQUE : pour que RDM fonctionne correctement, l’équipement compatible RDM doit être utilisé...
  • Page 39: D É C L A R At I O N D E L A F C C

    M A I N T E N A N C E L’appareil NETRON RDM6D d’Obsidian Control Systems est conçu pour être robuste et en bon état de marche. Le seul entretien requis est un nettoyage occasionnel. Pour d’autres problèmes liés à l’entretien, veuillez contacter votre revendeur Obsidian Control Systems ou visitez www.obsidiancontrol.com.
  • Page 40: Spécifications

    S P E C I F I C AT I O N S Montage : Rail DIN Montage mural Connexions: Avant : Plaque de connexion DMX à 6 ports (RJ45 ou borne) ou plaque de couverture Plaque de connexion DMX dans 2 ports (RJ45 ou borne) ou plaque de couverture Côté...
  • Page 41: Dimensions

    D I M E N S I O N S Les dessins ne sont pas à l’échelle. 7.1in. [180mm] 2.7in. [67mm] 2.1in. [54mm] 1.7in. [44mm]...

Table of Contents