IMPORTANT: Before installing this tankless reverse osmosis Tools and Materials Required IMPORTANT: Before installing this tankless reverse osmosis Tools and Materials Required system, make certain your water supply complies with the system, make certain your water supply complies with the •...
How Reverse Osmosis Works Installation The Tankless Reverse Osmosis (RO) System uses a semi-permeable GROUNDING INSTRUCTIONS: This appliance must be grounded. membrane to reduce dissolved salts and minerals, improving the In the event of a malfunction or breakdown, grounding will reduce taste and odor of your water.
Page 5
Installation Continued 1. Installing the Water Supply Adapter codes permit, it may be used to connect the system to the cold water supply line. If local codes do not permit the use of the supply adapter, alternate connectors can be obtained from your local supplier. Directions: (A) Turn off cold water supply line.
Page 6
Installation Continued Faucet Body Upper Gasket 3. Mounting the Faucet Countertop NOTE: Not all parts provided with the faucet may be needed for installation. Gasket Ring (A) Slide chrome plate and black rubber washer onto faucet by threading both drain tubes through the holes on the plate and washer. Below Gasket (B) Atta Installation Knob...
Installation Continued 7. Connecting the Faucet to the System (A) Determine the length of plastic white tubing needed to connect from the system to the faucet. Be sure to allow enough tubing to prevent kinking and cut the tubing squarely. Use a marker to mark one end of the tubing 5/8" from the end.
NOTE: have a 12 month timer, and the membrane has a 24 month timer. Ensure the correct cartridge is purchased for the system. Pentair Tankless RO System #4006877 uses the following replacements: • #4006882 / ROM-24M / Replacement RO Membrane •...
Indicator Status System Error Indications Error Type Indicator Lights Fault Indicator Recover Method Power off and then power back Timeout fault Go out on the system Power off and then power back Frequent start-stop Go out on the system Water leakage Locate and repair water leak Power off and then power back Low temperature...
Machine Functions Filter Cartridge Function Action Logic Fault Indicator Indicator Initial system Blue-Purple-Red indicator Blue-Purple-Red Beeps 0.1 second, indicator display 3 seconds power on light indicator light First time use Flashing according to Blue light always on hours washing current water NOTE: View To Complete 24-hour Flushing section quality status on the bottom of page 10.
Troubleshooting High TDS in Product Water If high levels of TDS (Total Dissolved Solids) are detected in your product water as determined by a TDS Monitor, the cartridge 1. Relieve pressure by turning off the water supply to the system membrane may need to be replaced.
Tankless RO Replacement Parts Part Number Description Quantity Image 4006967 SMART FAUCET POWER ADAPTER, 120V 60Hz 4006889 US PLUG 4006888 3/8" PE TUBING, WHITE 60 inches 4006887 1/4" PE TUBING, WHITE 60 inches 4006886 1/4" PE TUBING, RED 60 inches 4006882 RO MEMBRANE CARTRIDGE COMPOSITE AND CARBON...
Performance Data Model T600RO Installed With CB-12M, CF-12M, and ROM-24M Cartridges IMPORTANT: Testing is performed under standard laboratory conditions, actual performance may vary. Read this performance data and compare the capabilities of this Tankless RO Model system with your actual water treatment needs. The Tankless RO...
Need help?
Do you have a question about the T600RO and is the answer not in the manual?
Questions and answers