DECTRIS EIGER
Document Version v1.8.1
®
2 R 4M-RW
DECTRIS Ltd.
5405 Baden-Daettwil
Switzerland
www.dectris.com

Advertisement

loading
Need help?

Need help?

Do you have a question about the EIGER 2 R 4M-RW and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Dectris EIGER 2 R 4M-RW

  • Page 1 Technical Specifications ® DECTRIS EIGER 2 R 4M-RW Document Version v1.8.1 DECTRIS Ltd. 5405 Baden-Daettwil Switzerland www.dectris.com...
  • Page 2 Document Version v1.8.1 © Copyright 2023 DECTRIS Ltd.
  • Page 3 Mounting the Detector Control Unit ........23 ® DECTRIS EIGER 2 R 4M-RW Technical Specifications v1.8.1...
  • Page 4 Cleaning and Maintenance ......... . 27 TROUBLESHOOTING ® DECTRIS EIGER 2 R 4M-RW Technical Specifications v1.8.1...
  • Page 5 Fixed EIGER2 vacuum operation and updated trademarks. v1.8.0 2022-03-22 Documenting new features from release 2022.1 v1.8.1 2023-02-10 Updated frame rates and 8 bit mode for X and XE systems. ® DECTRIS EIGER 2 R 4M-RW Technical Specifications v1.8.1 iii | 30...
  • Page 6 1. GENERAL INFORMATION 1.1. Contact and Support Address: DECTRIS Ltd. Taefernweg 1 5405 Baden-Daettwil Switzerland Phone: +41 56 500 21 02 Fax: +41 56 500 21 01 Homepage: http://www.dectris.com/ Email: support@dectris.com Should you have questions concerning the system or its use, please contact us via telephone, mail or fax.
  • Page 7 (in particular information, images or ® materials), unless otherwise indicated. Without the written permission of DECTRIS it is prohibited to integrate the protected contents in this publication into other programs or other websites or to use them by any other means.
  • Page 8 ® We recycle DECTRIS detector systems that are no longer suitable for use. If you are not using your DECTRIS detector system any more, send it back to us. We will make sure that your system is responsibly and safely recycled. This is free for ®...
  • Page 9 235.0 mm x 237.0 mm x 371.8 mm Weight 15 kg Overvoltage category Means of protection I (power supply) Values are for Cu radiation Single threshold. Using two thresholds halves the frame rate. ® DECTRIS EIGER 2 R 4M-RW Technical Specifications v1.8.1 4 | 30...
  • Page 10 48 VDC, 6.25 A max., 300 W AC connector IEC-320-C14 input inlet Case dimensions (W x H x D) 112.0 mm x 45.0 mm x 220.0 mm Weight 1.6 kg ® DECTRIS EIGER 2 R 4M-RW Technical Specifications v1.8.1 5 | 30...
  • Page 11 Dimensions (W x H x D) 300 mm x 290 mm x 455 mm Weight 27.5 kg −1 Typical flow 3 L min Maximum operation pressure 3 bar ® DECTRIS EIGER 2 R 4M-RW Technical Specifications v1.8.1 6 | 30...
  • Page 12 • Make sure the temperature and the humidity inside the transport box does not exceed the specified range (use of a drying agent is required). • Ensure that no condensation moisture develops if the detector is stored at low temperature. ® DECTRIS EIGER 2 R 4M-RW Technical Specifications v1.8.1 7 | 30...
  • Page 13 4.1.1. Technical Drawing Information ® 3D step files of the EIGER2 R 4M-RW detector are available on request. Please contact DECTRIS technical support for more information. Figure 4.1: Drawing of the EIGER2 R 4M-RW Detector (also printed separately in the user documentation folder) ®...
  • Page 14 Do not apply any force on the screws, the screws do not need to be tightened to hold the cover in place and excessive force can damage the housing. Figure 4.2: The EIGER2 R 4M-RW Detector with the Cover Removed (front view) ® DECTRIS EIGER 2 R 4M-RW Technical Specifications v1.8.1 9 | 30...
  • Page 15 4.1.3. Back Side of the Detector Figure 4.3: The EIGER2 R 4M-RW Detector (back view) ® DECTRIS EIGER 2 R 4M-RW Technical Specifications v1.8.1 10 | 30...
  • Page 16 Do not replace the optical transceivers, as proper function of the detector system cannot be guaranteed otherwise. Please contact support@dectris.com if you need replacement transceivers. Caution There must be a 2 x LC/UPC duplex fiber optic con- nectors point-to-point connection between detector and detector control unit.
  • Page 17 Caution For in-vacuum operation do not use the standard con- nectors. A specific vacuum feedthrough set containing ® all required parts is available from DECTRIS 4.2. Detector Control Unit 4.2.1. Configuration Caution Do not access or modify the operating system of the detector control unit.
  • Page 18 Inteface Name: user1p1 (1 GBase-T) User configurable GbE Network Interface Preconfiguration: DHCP service (Embedded) Inteface Name: service (1 GBase-T) Fallback GbE Network Interface Preconfiguration: Static 169.254.254.1 (Netmask 255.255.255.0) ® DECTRIS EIGER 2 R 4M-RW Technical Specifications v1.8.1 13 | 30...
  • Page 19 Before operating the thermal stabilization unit, please read the User Manual of the thermal stabilization unit. Caution When connecting or disconnecting the cooling hoses, turn off the detector and the thermal stabilization unit. ® DECTRIS EIGER 2 R 4M-RW Technical Specifications v1.8.1 14 | 30...
  • Page 20 Prior to powering up and operating the detector in-vacuum the thermal stabilization unit has to be set to a temperature of 17 °C for at least 30 min. ® DECTRIS EIGER 2 R 4M-RW Technical Specifications v1.8.1 15 | 30...
  • Page 21 Caution ® ® The screws holding the Mylar frame are close to the Mylar foil, be careful that the screw driver does not slip and damage the frame. ® DECTRIS EIGER 2 R 4M-RW Technical Specifications v1.8.1 16 | 30...
  • Page 22 For mechanical protection the cover can be mounted, but the sensors are still unprotected from humidity and dust. ® Figure 5.1: The EIGER2 R 4M-RW Detector without the cover and Mylar frame in place (front view). ® DECTRIS EIGER 2 R 4M-RW Technical Specifications v1.8.1 17 | 30...
  • Page 23 Approved by 173300.M.00.L10 Freigegeben Title Date of Issue EIGER2 4M-RW Outline 19.11.2021 DECTRIS Ltd. Taefernweg 1 5405 Baden-Daettwil, Switzerland Comment / Item number Sheet We reserve all rights in connection with this 2 / 2 173300.M.00.L10 EIGER2 4M-RW Outline document. Without our agreement it may be neither copied nor made accessible to a third party.
  • Page 24 Figure 5.3: Drawing of the EIGER2 R 4M-RW Detector Base Plate (also printed separately in the user documentation folder) Caution The four M6 screws must not intrude into the detector more than 10 mm. ® DECTRIS EIGER 2 R 4M-RW Technical Specifications v1.8.1 19 | 30...
  • Page 25 Although the detector might be already grounded via the mounting bolts, the detector should be grounded additionally via the functional ground connector at the back in order to establish a defined grounding. ® DECTRIS EIGER 2 R 4M-RW Technical Specifications v1.8.1...
  • Page 26 Detectors used in vacuum need different optical cables. For information about vacuum cables, refer to the vacuum ® feedthrough set specifications or contact DECTRIS support. 5.6.1. Installing the Cables The fiber optic cables come with a pulling eye to make cable installation easier and a cable sock to protect the connectors.
  • Page 27 Do not add any component other than those supplied by DECTRIS to the cooling circuit. Using the wrong material in the ® cooling circuit leads to galvanic corrosion, which can permanently damage the detector. Contact DECTRIS support at support@dectris.com in case the supplied components are not compatible with your setup.
  • Page 28 The mains plug of the detector control unit has to be connected to a grounded power outlet. The detector control unit can be mounted in a standard 19 inch rack, which has to be properly grounded. ® DECTRIS EIGER 2 R 4M-RW Technical Specifications v1.8.1...
  • Page 29 5.5. Then restart the software. Information A free-flowing air stream is mandatory in order to properly cool the electronics inside the detector. Do not cover any ventilation holes. ® DECTRIS EIGER 2 R 4M-RW Technical Specifications v1.8.1 24 | 30...
  • Page 30 • Do not remove the nitrogen/dry air connection. It is a requirement that it is left at the recommended flow rate according to section 5.5. Warning As long as the detector power cable is connected, the detector has to be considered under power. ® DECTRIS EIGER 2 R 4M-RW Technical Specifications v1.8.1 25 | 30...
  • Page 31 To see if a detector is vacuum compatible, check whether the vacuum compatibility option is included in the order confir- ® mation received from DECTRIS 7.4.1. Ambient Conditions for In-Vacuum Use For in-vacuum operation of the detector following conditions must be fulfilled: Table 7.1: In-Vacuum Operating Conditions...
  • Page 32 ® ® The Mylar foil must not be touched or cleaned. If it is damaged, please contact DECTRIS technical support. The detector housing can be cleaned with a soft tissue. The EIGER2 R 4M-RW detector does not require any maintenance.
  • Page 33 Table 8.1 provides an overview of possible problems with the detector system and instructions in order to solve the problems. If the problem you are experiencing is not listed below or if the instructions do not help, please contact support@dectris.com.
  • Page 34 Ambient humidity around the detector Shut down the detector immediately exceeds the operating conditions. and check the humidity. Power up the detector only when the ambient hu- midity has been reduced. ® DECTRIS EIGER 2 R 4M-RW Technical Specifications v1.8.1 29 | 30...
  • Page 35 ”DECTRIS INSTANT RETRIGGER”, ”DECTRIS MYTHEN”, ”DECTRIS PILATUS”, ”DECTRIS QUADRO”, ”DECTRIS SANTIS”, ”DECTRIS SÄNTIS”, ”DECTRIS SINGLA”, ”DECTRIS TITLIS”, ”DETECTING THE FUTURE” © 2/ 2023 DECTRIS Ltd., all rights reserved • Subject to technical modifications. ® DECTRIS EIGER 2 R 4M-RW Technical Specifications v1.8.1...