Download Print this page
Hide thumbs Also See for BRACKET PRO 77FL:

Advertisement

Quick Links

EMS
®
BRACKET PRO SERIE
77 FL
®
USER MANUAL
SAFETY AND FLEXIBILITY
WHERE IT MATTERS MOST

Advertisement

loading
Need help?

Need help?

Do you have a question about the BRACKET PRO 77FL and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for TECHNIMOUNT BRACKET PRO 77FL

  • Page 1 ® BRACKET PRO SERIE 77 FL ® USER MANUAL SAFETY AND FLEXIBILITY WHERE IT MATTERS MOST...
  • Page 2 Copyright 2025 Technimount E.M.S. Holding Inc. is an affiliated company of Technologies CGC Inc. All Rights Reserved. No part of this publication may be reproduced, transmitted, transcribed, backed-up on a retrieval system, translated in any language, modified in any form or by any means, without the written permission of Technimount or its affiliate companies.
  • Page 3 Annex III Prepare the Bracket Pro Serie 77 FL ....................23 ..Required Installation Time ..............................23 ..Required Tools ..................................23 ..Install the medical device in the Bracket Pro Serie 77 FL ....................23 © 2025 Technimount E.M.S. Holding Inc. UM-BP77FL-202501EN-01 | Page iii of iv...
  • Page 4 ..Maintenance Frequency ..............................30 ..Required Tools ..................................30 ..Tested Cleaning Solutions ..............................30 ..Maintenance Plan ................................31 ..Illustrated Inspection Points ..............................33 Annex V Replacement Parts/Kits ........................35 © 2025 Technimount E.M.S. Holding Inc. UM-BP77FL-202501EN-01 | Page iv of iv...
  • Page 5 The Bracket Pro Serie 77 FL user manual includes detailed product information, standards and guidelines to assist the administrator/manager/supervisor and biomedical technician (or equivalent) with the unpacking, assembling (when indicated) and maintenance of the Technimount product. It also includes specific user-related information to assist trained EMS and clinical personnel with effectively operating the support bracket.
  • Page 6 Technimount. The product defined as a "support bracket" is specifically designed to fill this requirement. Any other use will void the warranty and Technimount shall not be held liable on any claim if the product has been modified or adapted for use.
  • Page 7 Claims are limited in amount to the actual replacement cost. If the claim has not been received by Technimount within the fifteen (15) day period following the date of delivery, or the damage was not noted on the delivery receipt at the time of receipt, the customer will be responsible for the full payment of the original invoice.
  • Page 8 Upon reception of the returned merchandise, a thorough inspection will be performed. If the merchandise is compliant with the return policy or it is found that the product is defective, Technimount will take corrective actions and close the claim. If, however, it is found that the product is not defective, but rather misused or abused, the product will not be covered by the warranty.
  • Page 9 EMS and clinical personnel, or damage to the product. This includes the special care necessary for the safe and effective use of the Technimount product to avoid damage that may occur from use or misuse. The terms "Warning" and "Caution" herein carry special meaning and should be carefully reviewed.
  • Page 10 ® 2.2. Labels Labelling on the surface of the Technimount product, quickly identify potential risks and provides information to the user. A manufacturing label, including the serial number and safe working load (Figure 1), can be seen on the Technimount product.
  • Page 11 EMS and clinical personnel. Refer to the « Technical Specifications » on page 12 for compatibilities. - Improper use of the Technimount product may damage it or cause injury to the patients or EMS and clinical personnel.
  • Page 12 - Lavo 12, 10 000 ppm Sodium Hypochlorite ® Cleaning Solutions - TNT-100, 5% Quaternary Ammonium Compound - Spectro-Sept, 5% Ethyl Alcohol - Spectrol, 5% EDTA salt Options © 2025 Technimount E.M.S. Holding Inc. UM-BP77FL-202501EN-01 | Page 12 of 36...
  • Page 13 Figure 2: Bracket Pro Serie 77 FL orientation diagram with a back anti-rotation micro disc Left-hand side Right-hand side Left-hand side Right-hand side Front Back Figure 3: Bracket Pro Serie 77 FL orientation diagram with a bottom micro disc © 2025 Technimount E.M.S. Holding Inc. UM-BP77FL-202501EN-01 | Page 13 of 36...
  • Page 14 Figure 4: Bracket Pro Serie 77 FL components with a back anti-rotation micro disc 1. Retaining frame 3. Bottom plate with a micro disc 2. Micro disc Figure 5: Bracket Pro Serie 77 FL components with a bottom micro disc © 2025 Technimount E.M.S. Holding Inc. UM-BP77FL-202501EN-01 | Page 14 of 36...
  • Page 15 Figure 6: Illustration of the Bracket Pro Serie 77 FL with a back anti-rotation micro disc and medical device Figure 7: Illustration of the Bracket Pro Serie 77 FL with a bottom micro disc and medical device © 2025 Technimount E.M.S. Holding Inc. UM-BP77FL-202501EN-01 | Page 15 of 36...
  • Page 16 Figure 8: Installing the Bracket Pro Serie 77 FL with a back anti-rotation micro disc in a micro base Figure 9: Installing the Bracket Pro Serie 77 FL with a bottom micro disc in a micro base © 2025 Technimount E.M.S. Holding Inc. UM-BP77FL-202501EN-01 | Page 16 of 36...
  • Page 17 (Figure 11) or micro disc forward horizontally (Figure 12) out of the base: Figure 11: Removing the Bracket Pro Serie 77 FL with a back anti-rotation micro disc from the micro base © 2025 Technimount E.M.S. Holding Inc. UM-BP77FL-202501EN-01 | Page 17 of 36...
  • Page 18 Figure 12: Removing the Bracket Pro Serie 77 FL with a bottom micro disc from the micro base The removal of the Bracket Pro Serie 77 FL from the micro base is complete. © 2025 Technimount E.M.S. Holding Inc. UM-BP77FL-202501EN-01 | Page 18 of 36...
  • Page 19 - Able to operate the support bracket. - Has practiced safely operating the support bracket, has perfected the manipulations and has acquired the required skill level to safely use with patient. © 2025 Technimount E.M.S. Holding Inc. UM-BP77FL-202501EN-01 | Page 19 of 36...
  • Page 20 BRACKET PRO SERIE 77 FL ® User Manual ® © 2025 Technimount E.M.S. Holding Inc. UM-BP77FL-202501EN-01 | Page 20 of 36...
  • Page 21 Identify all the components and hardware included for the installation when applicable, then set aside. Inspect the items for signs of damage. Take pictures and report them promptly if applicable. © 2025 Technimount E.M.S. Holding Inc. UM-BP77FL-202501EN-01 | Page 21 of 36...
  • Page 22 BRACKET PRO SERIE 77 FL ® User Manual ® © 2025 Technimount E.M.S. Holding Inc. UM-BP77FL-202501EN-01 | Page 22 of 36...
  • Page 23 3. 10-32 X 1 in. Phillips flat head rotation micro disc screw (4X) 2. Bottom plate Figure 13: Assembly parts of the Bracket Pro Serie 77 FL with a back anti-rotation micro disc © 2025 Technimount E.M.S. Holding Inc. UM-BP77FL-202501EN-01 | Page 23 of 36...
  • Page 24 Figure 15: Installation of the medical device in the bottom plate © 2025 Technimount E.M.S. Holding Inc. UM-BP77FL-202501EN-01 | Page 24 of 36...
  • Page 25 To facilitate the installation, flip the medical device on its back to allow better access to the screw holes of the bottom plate and retaining frame. Figure 17: Medical device installed in the support bracket with a back anti-rotation micro disc © 2025 Technimount E.M.S. Holding Inc. UM-BP77FL-202501EN-01 | Page 25 of 36...
  • Page 26 To facilitate the disassembly, flip the medical device on its back to allow better access to the screws of the bottom plate. Figure 19: Removal of the retaining frame from the bottom plate © 2025 Technimount E.M.S. Holding Inc. UM-BP77FL-202501EN-01 | Page 26 of 36...
  • Page 27 Lift and remove the medical device vertically from the bottom plate (Figure 21 and Figure 22), then set it aside. Figure 21: Removal of the medical device in the bottom plate © 2025 Technimount E.M.S. Holding Inc. UM-BP77FL-202501EN-01 | Page 27 of 36...
  • Page 28 Figure 22: Removal of the medical device in the Bottom plate with a micro disc The removal of the medical device from the Bracket Pro Serie 77 FL is complete. © 2025 Technimount E.M.S. Holding Inc. UM-BP77FL-202501EN-01 | Page 28 of 36...
  • Page 29 - Use only Technimount parts, maintenance procedures, cleaning solutions and lubricants, as described herein. Using unapproved modified parts or procedures for the maintenance of the Technimount product may cause the system to be unstable and could cause injury to the patients or EMS and clinical personnel and void the product warranty.
  • Page 30 - Oxivir, 5% Hydrogen Peroxide with Peracetic Acid (AHP) - Lavo 12, 10 000 ppm Sodium Hypochlorite - TNT-100, 5% Quaternary Ammonium Compound - Spectro-Sept, 5% Ethyl Alcohol - Spectrol, 5% EDTA salt © 2025 Technimount E.M.S. Holding Inc. UM-BP77FL-202501EN-01 | Page 30 of 36...
  • Page 31 Thoroughly rinse the solution with a clean cloth dampened with lukewarm water, then dry all the components using a clean cloth before returning to service. © 2025 Technimount E.M.S. Holding Inc. UM-BP77FL-202501EN-01 | Page 31 of 36...
  • Page 32 BRACKET PRO SERIE 77 FL ® User Manual ® Comments and observations following the Safety Checks and Condition-Based Maintenance: Maintenance plan completed on (dd/mm/yyyy): Maintenance plan completed by: © 2025 Technimount E.M.S. Holding Inc. UM-BP77FL-202501EN-01 | Page 32 of 36...
  • Page 33 1. Retaining frame 3. Bottom plate with a micro disc 2. Micro disc Figure 24: Illustrated inspection points of the Bracket Pro Serie 77 FL with a bottom micro disc © 2025 Technimount E.M.S. Holding Inc. UM-BP77FL-202501EN-01 | Page 33 of 36...
  • Page 34 BRACKET PRO SERIE 77 FL ® User Manual ® © 2025 Technimount E.M.S. Holding Inc. UM-BP77FL-202501EN-01 | Page 34 of 36...
  • Page 35 ® User Manual ® Annex V Replacement Parts/Kits Technimount reserves the right to change part numbers and products without notice. Please contact Customer Service at customerservice@technimount.com to ensure product options and availability, or Technical Support at techsupport@technimount.com for replacement parts/kits or repair related issues.
  • Page 36 Critical Care Transport (CCT) teams for ground and air ambulances. Safety is at the core of our values, all Technimount systems are tested in compliance with the highest industry standards for impact resistance. Technimount EMS is committed to developing innovative solutions as healthcare practices evolve.