Download Print this page
Kohler BARDON K-4915T-2Y Installation Instructions Manual
Kohler BARDON K-4915T-2Y Installation Instructions Manual

Kohler BARDON K-4915T-2Y Installation Instructions Manual

Touchless wall hung urinal

Advertisement

Quick Links

BEFORE YOU BEGIN
BEFORE YOU BEGIN
A. HOW TO USE THESE INSTRUCTIONS
·
Please read these instructions carefully to familiarize
yourself with the required tools, materials, and installation
sequences. Follow the sections that pertain to your
particular installation. This will help you avoid costly
mistakes. In addition to proper installation, read all
operating and safety instructions.
·
All information in these instructions is base upon the latest
product information available at the time of publication.
Kohler China reserves the right to make changes in
product characteristics, packaging, or availability at any
time without notice.
·
The illustrations of product in this manual are only for
reference.
·
These instructions contain important care, cleaning, and
warranty information-
consumer
.
B. NOTES
·
Observe all local plumbing and building codes.
·
Stop Valve has a 1/2" NPT inlet supply connection.
· Fixture dimensions are nominal and conform to tolerances
established by ASME Standards (A112.19.2-2018).
·
The product complies with GB 6952-2015, GB 28377-
2019.
C. REQUIRED TOOLS AND MATERIALS
·
Open end/adjustable wrenches
·
Supply piping and connectors
·
Tape measure
·
Thread sealant tape
·
Basin Wrench
·
Screw driver
D. ROUGHING-IN
·
Turn off cold water supplies.
·
Install or relocate supply tubing and waste pipe to conform
to roughing-in dimensions.
·
See Fig. #1
for DC roughing-in dimension requirements.
·
See Fig. #2
for AC roughing-in dimension requirements.
* Urinal complies with ADA requirement when rim is mounted
no higher than 17" form finished floor.
No.2 KOHLER ROAD, SANSHUI CENTRAL INDUSTRIAL PARK, LEPING TOWN, SANSHUI DIST., FOSHAN, GUANGDONG, PRC POST CODE 528137
8# MENGSHAN RD, ECONOMIC DEVELOPMENT ZONE OF HUANTAI, ZIBO, SHANDONG, CHINA
NO.1 KOHLER STREET, ECONOMIC DEVELOPMENT ZONE OF FAKU COUNTY, SHENYANG LIAONING PROVINCE, PRC
1146969-T2-A
please leave instructions for the
TOUCHLESS WALL HUNG URINAL
A.
·
·
·
·
B.
·
·
1/2" NPT
·
2018)
·
GB 6952-2015 GB 28377-2019
C.
·
/
·
·
·
·
·
D.
·
·
·
·
*
2
528137
8
256410
1
110400
©
Copyright Kohler China Investment Co., Ltd. 2022
-1-
©
BARDON
INSTALLATION INSTRUCTIONS
K-4915T-2Y(0.5L)
K-4915T-2W(1L)
K-4915T-2(2.5L)
.
.
ASME
(A112.19.2-
1
2
432mm
POST CODE:
256410
POST CODE:
-
:
110400
2022

Advertisement

loading
Need help?

Need help?

Do you have a question about the BARDON K-4915T-2Y and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Kohler BARDON K-4915T-2Y

  • Page 1 * Urinal complies with ADA requirement when rim is mounted 432mm no higher than 17" form finished floor. No.2 KOHLER ROAD, SANSHUI CENTRAL INDUSTRIAL PARK, LEPING TOWN, SANSHUI DIST., FOSHAN, GUANGDONG, PRC POST CODE 528137 528137 8# MENGSHAN RD, ECONOMIC DEVELOPMENT ZONE OF HUANTAI, ZIBO, SHANDONG, CHINA...
  • Page 2 610+ To Floor Outlet Details *610 2" N.P.S Tap Fig.2 Kohler reserves the right to change marked dimensions without prior notice. NOTE: Roughing-in dimension requirements for supply tubing as shown. · · 22-32mm Supply tubing is 22-32mm out of the wall. Otherwise. stop valve can not be installed and adjuested properly.
  • Page 3 INSTALLATION 1. MOUNT URINAL See Fig.#3 Install hangers per roughing-in illustration. Apply sealant tape to pipe threads and install female collar on waste pipe. Place washer on female collar. Install Urinal. Secure urinal to female collar with screws and washers. CAUTION: Risk of chipping or breaking urinal.
  • Page 4 Use DC or AC power unit as desired (not supplied). Refer to the installation instructions below. Use the Kohler specified AC or DC power supply. Any product damage or loss caused by the use of non-specified power supply shall be borne by the user.
  • Page 5 Install DC Power Unit (DC battery box K-29183T-NA needs to K-29183T-NA) be purchased separately) please refer to step 3 directly. Install AC Power Unit (AC power box K-16306T-NA needs to K-16306T-NA) be purchased separately), the way of installation is as below: CAUTION: a.
  • Page 6 3. INSTALL BATTERIES (Only for DC) See Fig.#10 Turn on stop valve. Inspect pipes for leakage in not flushing. Connect the connector of sensor window with the connector of solenoid valve. Remove the battery box cover and insert alkaline batteries into the battery box.Reinstall the cover of the baottery box and tighten it with battery box with screws.
  • Page 7 USER S GUIDE USER S GUIDE Don't use this system after 10 minutes power on. The induction distance will be adjusted and this system will not work during this time. The state of distance adjustment has been last about 10 minutes after power on.
  • Page 8 FLUSHING DURATION (Only for K-4915T-2) When first installed or during use, if the flushing volume is Flushing Control Stick reduced (due to low water pressure), the flushing duration can be adjusted. Power off until the indicator stops flashing. During the first 10 minutes after power on, approach the flushing control stick to the center of the sensor window for about 8 seconds.
  • Page 9 SENSOR SPECIFICATION SENSOR SPECIFICATION K-4915T-2Y(0.5L) Model K-4915T-2W(1L) K-4915T-2(2.5L) 2 piece of AAA sized alkaline batteries(DC) Power Supply 220V AC 50/60Hz(AC) Power Consumption The batteries can be used about two years(4000 times a month) Induction Distance Automatic adjustment according to the ambient circumstance Detection Duration About 2 seconds or 5 seconds (automatic adjustment) Double flushing(K-4915T-2)
  • Page 10 TROUBLESHOOTING Make sure to complete the procedures following before asking for repair: Symptoms Probable causes Corrective actions No flushing (indicator lamp 1. Batteries reversed. (only for DC) 1. Check the batteries. (Only for DC) 2. There are other objects are being detected. 2.
  • Page 11 Kohler inspection results. The product is designed not to hurt the environment. Under current technology, all hazardous materials have been used in the smallest amounts possible. Kohler will strive to reduce the use of these hazardous materials used in this product.
  • Page 12 (Hg) (Pb) (Cd) (Cr(VI)) (PBB) (PBDE) GB/T 26572 GB/T 26572 -12- 1146969-T2-A...

This manual is also suitable for:

Bardon k-4915t-2wBardon k-4915t-2