Table 1-7. LCD Status Messages (continued)
Code
Text
E2111
SBE Log Disable
Crd # DIMM ##
E2112
Mem Spare Crd #
DIMM ##
E2113
Mem Mirror Crd #
DIMM ## & ##
Fatal NB Mem CRC One of the connections in the FBD
E2118
E2119
Fatal SB Mem CRC One of the connections in the FBD
I1910
Intrusion
I1911
>3 ERRs Chk Log
Causes
The system BIOS has disabled
memory single-bit error (SBE)
logging, and will not resume
logging further SBEs until the
system is rebooted. "##" represents
the DIMM implicated by the
BIOS. If no memory riser card is
present, the "Crd #" string is left
out of the message.
The system BIOS has spared the
memory because it has determined
that the memory had too many
errors. "## & ##" represents the
DIMM pair implicated by the
BIOS. If no memory card is
present, the "Crd #" string is left
out of the message.
The system BIOS has disabled
memory mirroring because it has
determined that one half of the
mirror has had too many errors.
"## & ##" represents the DIMM
pair implicated by the BIOS. If no
memory card is present, the "Crd
#" string is left out of the message.
memory subsystem link on the
Northbound side has failed.
memory subsystem link on the
Southbound side has failed.
System cover has been removed.
LCD overflow message.
A maximum of three error
messages can display sequentially
on the LCD. The fourth message
displays as the standard overflow
message.
Corrective Actions
See "Troubleshooting System
Memory" on page 102.
See "Troubleshooting System
Memory" on page 102.
See "Troubleshooting System
Memory" on page 102.
See "Troubleshooting System
Memory" on page 102.
See "Troubleshooting System
Memory" on page 102.
Information only.
Check the SEL for details on the
events.
About Your System