Page 1
Operating Instructions U30T001 Distance Sensor Translation of the original operating instructions Subject to change without notice Available as PDF file only Version 2.0 www.wenglor.com...
Page 3
7.4 Condition Monitoring/Process Data..........................28 7.4.1 Process Data In ............................... 28 7.4.2 Process Data Out..............................29 7.4.3 Events..................................29 8 Maintenance Instructions ............................. 30 9 Proper Disposal ................................31 10 Declarations of Conformity............................32 Table of Contents | U30T001 ‒ Distance Sensor...
Page 4
The safety precautions and warnings are laid out in accordance with the following principle: SIGNAL WORD Type and source of danger! Possible consequences in the event that the hazard is disregarded. à Measures for averting the hazard. 1 ‒ General | U30T001 ‒ Distance Sensor...
Page 5
• wenglor assumes no liability for printing errors or other inaccuracies contained in these operating in- structions unless wenglor was verifiably aware of such errors at the point in time at which the operat- ing instructions were prepared.
Page 6
• All rights are reserved by wenglor. • Commercial reproduction or any other commercial use of the provided content and information, in particular graphics and images, is not permitted without previous written consent from wenglor. 1 ‒ General | U30T001 ‒ Distance Sensor...
Page 7
• The product is not suitable for use in potentially explosive atmospheres. • The product may be used only with accessories supplied or approved by wenglor, or in combination with approved products. A list of approved accessories and combination products can be found at www.wenglor.com on the product detail page.
Page 8
Read the operating instructions carefully before using the product. Protect the sensor against contamination and mechanical influences. Approvals and Protection Class IND. CONT. EQ 72HL / E189727 For use in class 2 circuits 2 ‒ For Your Safety | U30T001 ‒ Distance Sensor...
Page 9
Housing Material Plastic, PA Brass, nickel-plated Degree of Protection IP67 Connection M12 × 1; 4/5-pin Technical Safety Data MTTFd (EN ISO 13849-1) 1317.9 a Output Functions Output Adjustable Parameters Output Error Output 3 ‒ Technical Data | U30T001 ‒ Distance Sensor...
Page 10
During the warm-up phase, the values improve in the form of an exponential function until the values in the technical data are reached. The switch-on drift during this time is shown in the following diagram. 3 ‒ Technical Data | U30T001 ‒ Distance Sensor...
Page 11
Measurement of the sonic cone on a 100 × 100 mm plate Characteristic curves show the position of the center or the front edge of the measured object (100 × 100 mm plate) at the time of switching. 3 ‒ Technical Data | U30T001 ‒ Distance Sensor...
Page 12
Standard sonic cone (center of the measured object) Extra-narrow sonic cone (center of the measured object) Standard sonic cone (front edge of the measured object) INFORMATION Please note that using multiple ultrasonic sensors can cause reciprocal influence. 3 ‒ Technical Data | U30T001 ‒ Distance Sensor...
Page 13
Dimensions specified in mm (1 mm = 0.03937") Complementary Products wenglor offers you the right connection and mounting technology as well as other accessories for your product. You can find this at www.wenglor.com on the product details page at the bottom.
Page 14
Scope of Delivery • Sensor • Safety precaution 3 ‒ Technical Data | U30T001 ‒ Distance Sensor...
Page 15
• Protect the product against exposure to direct sunlight. NOTICE Risk of property damage in case of improper storage! The product may be damaged. à Storage instructions must be complied with. 4 ‒ Transport and Storage | U30T001 ‒ Distance Sensor...
Page 16
Risk of personal injury or property damage due to electric current. Voltage-conducting parts may cause personal injury or damage to equipment. à The electric device may be connected by appropriately qualified personnel only. 5 ‒ Installation and Electrical Connection | U30T001 ‒ Distance Sensor...
Page 17
Interfaces-Bus A(+)/B(–) Violet Emitted Light disengageable Grey Safety Output Signal Output White Magnet activation Pink Ethernet Gigabit bidirect. data line (A-D) Input confirmation Green/Yellow Encoder 0-pulse 0-0 (TTL) Contactor Monitoring 5 ‒ Installation and Electrical Connection | U30T001 ‒ Distance Sensor...
Page 18
Via IO-Link, it is possible to identify the respective causes precisely by means of condition monitoring. Fur- ther diagnosis functions and status messages are also possible. See section Condition Monitoring/Process Data [} 28]. 6 ‒ Diagnosis | U30T001 ‒ Distance Sensor...
Page 19
1. Shut down the machine. 2. Analyze and eliminate the cause of error with the aid of the diagnostics information. 3. If the error cannot be eliminated, please contact wenglor’s support department. 4. Do not operate in case of indeterminate malfunctioning.
Page 20
To this end, the sensor is connected to a suitable IO-Link master (see product detail page/complementary products). The interface protocol and the IODD can be found at www.wenglor.com in the download area for the respective product. For information on installing and connecting the wTeach2 software and its structure, as well as information on the general functions, see the wTeach2 operating instructions.
Page 21
2. Set up another sensor as a receiver. 3. If the receiver is operated as a normally closed contact, it is switched when an object is located be- tween the emitter and the receiver. 7 ‒ Settings | U30T001 ‒ Distance Sensor...
Page 22
A maximum of 16 sensors can be used together in multiplex mode in order to detect a larger surface area. The sensors emit pulsed ultrasonic pulses alternately. 1. Connect all of the sensors’ pin 5 terminals to each other. 7 ‒ Settings | U30T001 ‒ Distance Sensor...
Page 23
Median filter of 11 measured values Median filter of 12 measured values Median filter of 13 measured values Median filter of 14 measured values Median filter of 15 measured values Median filter of 16 measured values 7 ‒ Settings | U30T001 ‒ Distance Sensor...
Page 24
Read-out of distance values in 1/10 inch for internal temperature compensation or external temperature compensation via the param- eters Millimeter (with external temperature) Output of distance values in mm and input of external temperature via Process Data Out 7 ‒ Settings | U30T001 ‒ Distance Sensor...
Page 25
The sensor’s transmit signal is deactivated as long as the in- put is activated. The sensor does not send a measured value and sets the status to “No signal”. Teach-in input 7 ‒ Settings | U30T001 ‒ Distance Sensor...
Page 26
(switching point, warning, error). Normally Closed (NC) The output is low when the condition has been satisfied, de- pending on settings (switching point, warning, error). Additional hysteresis 0…200 mm 0 mm On-delay 0…10,000 ms 0 ms 7 ‒ Settings | U30T001 ‒ Distance Sensor...
Page 27
This function simulates the behavior of the sensor regardless of the current status and measured value. This can be used to check whether a plant in which the sensor is integrated reacts correctly to the data supplied by the sensor and processes them accordingly. 7 ‒ Settings | U30T001 ‒ Distance Sensor...
Page 28
Status message 1 read out see Status Message Function [} 27] Message 2 Status message 2 read out see Status Message Function [} 27] Message 3 Status message 3 read out see Status Message Function [} 27] 7 ‒ Settings | U30T001 ‒ Distance Sensor...
Page 29
The following events are supported: Name Event code Type Specification Device error – unknown error 0x1000 Error IO-Link Short circuit – check installation 0x7710 Error IO-Link Supply voltage too low – check tolerances 0x5111 Warning IO-Link 7 ‒ Settings | U30T001 ‒ Distance Sensor...
Page 30
Cleaning and inspection of the plug connections at regular intervals are advisable. Do not clean the product with solvents or cleaning agents that could damage the product. The product must be protected against contamination during initial start-up. 8 ‒ Maintenance Instructions | U30T001 ‒ Distance Sensor...
Page 31
Proper Disposal wenglor sensoric GmbH does not accept the return of unusable or irreparable products. Respectively valid national waste disposal regulations apply to product disposal. 9 ‒ Proper Disposal | U30T001 ‒ Distance Sensor...
Page 32
Declarations of Conformity Declarations of conformity can be found on our website at www.wenglor.com in the product’s separate download area. 10 ‒ Declarations of Conformity | U30T001 ‒ Distance Sensor...
Need help?
Do you have a question about the U30T001 and is the answer not in the manual?
Questions and answers