Functional Lock - Pioneer PDP-607CMX Technical Manual

Plasma display monitor
Hide thumbs Also See for PDP-607CMX:
Table of Contents

Advertisement

Integrator Mode

25) FUNCTIONAL LOCK

This is the FUNCTIONAL LOCK function that prevents operation from the main unit panel or the remote control in
order to prevent improper operation after installation (The RS-232C command is effective.)
While the FUNCTIONAL LOCK is set, if the remote control or main unit operating panel are operated, the following
are displayed in the center of the screen.
• 'BUTTONS LOCK'
• 'IR LOCK'
• 'BUTTONS & IR LOCK'
• 'MEMORY LOCK' *
* 'MEMORY LOCK'
The input functions, volume, and multi-screen display status when 'MEMORY LOCK' is set are stored in memory,
and when the power is turned on, the display complies with this information.
When it is shipped from the factory, the lock is set to OFF, so the remote control and the main unit panel can be
operated.
Factory setting: Lock OFF
The following are two setting methods.
1) Main unit operating panel (concealed)
Each time the [FUNCTIONAL LOCK (concealed)] button is pressed, the switching occurs in the following sequence.
3
BUTTONS LOCK
To turn the lock OFF, press and hold the [FUNCTIONAL LOCK (concealed)] button for at least about five seconds.
2) RS-232C command
Refer to "5.5.5 List of RS-232C Commands (pg. 194)".
Note
When POWER ON MODE has been simultaneously set, POWER ON MODE has priority.
182
3 IR LOCK
3
BUTTONS & IR LOCK
3
MEMORY LOCK

Advertisement

Table of Contents
loading

Table of Contents