Installation Conditions (Pdp-503Cmx/Pdp-503Mxe); Heat Dissipation - Pioneer PDP-433CMX Technical Manual

Plasma display monitor
Hide thumbs Also See for PDP-433CMX:
Table of Contents

Advertisement

Installation Conditions

3.2 Installation Conditions (PDP-503CMX/PDP-503MXE)

3.2.1 Heat dissipation

This unit has openings for effective ventilation at locations marked by arrows in the illustration below. To allow proper
dissipation of heat from the unit, do not cover any of these openings.
(Unit : mm)
154
82 40
166.5
138
Two fans and part A in a normal installation case draw off hot air from the unit. All openings not assisted by fans
serve as air inlets. If the unit is hung from or embedded into a wall, special operating temperature limits and other
limitations may apply. Refer to "3.5 Special Installation".
22
80
A
Fan (2 in number)
165
176
500
425
[503CMX/503MXE]
80
154
40
82
165
166.5
164
140

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pdp-503cmxPdp-503mxePdp-433mxe

Table of Contents