7.2 Maintenance
Regular inspection and servicing have a positive effect on the reliable
functioning of the product and should be carried out at least once a year.
Except for the necessary filter replacements, the product operates
maintenance-free.
Observe the warning notices for servicing and troubleshooting in the
"Safety" chapter.
7.3 Daily checks before starting work
Test
Check the connection cable and
plug (if present) for damage
Check the connected ducting
system for leaks
Check the fill level of the dust
collection container (if present).
Check the maintenance
doors/maintenance covers for leaks
Check the filter(s) for damage (filter
breakthrough)
WARNING
Health hazard due to welding fumes
If the filter surface is damaged (filter breakthrough), the filtration of the
air containing pollutants is no longer given. Operation of the product
must be stopped immediately.
A filter change is required. See chapter Changing Filters
7.3.1 Emptying the dust collection container
The dust collection container fill level must be checked at regular intervals.
The time period in which the dust collection bucket/disposal bag must be
changed depends on the type and quantity of use of the separated dust
particles. For this reason, we cannot state specific replacement intervals.
1502867-00
Instructions
If necessary, inform a qualified
electrician
Mend or replace any damaged parts
See "Maintenance" chapter
Have any defective seals replaced
Visually check if smoke is coming
out of the clean air outlet during the
welding process or if dust deposits
are visible in the area of the clean air
outlet.
Tab. 22: Daily checks