CEILING FAN INSTRUCTION BOOKLET Thank you for purchasing your Fanco Sanctuary DC Ceiling Fan. Please read all instructions carefully before assembly and use. IMPORTANT SAFEGUARDS: Read all instructions carefully, even if you feel you are quite familiar with this type of appliance. When...
21. The LED light panel in light kit is user replaceable as it connects with 'Push Plug' wiring. It is user replaceable ONLY with Fanco certified replacement LED panels. Using unauthorised parts may damage the fan, cause undesired results, or be a safety hazard.
FAULT FINDER: Always check the “Trouble Shooting Checklist” included in this manual before seeking a warranty claim. A mechanical noise may be noticed on installation. Allow at least 8 hours settling-in period. Some fans may wobble more than others, even if they are identical. This does not necessarily indicate a fault.
INSTALLATION AND ASSEMBLY: CAUTION! Before installing the fan make sure you have turned OFF the electricity supply. SELECTING A LOCATION: 1. Choose a location for mounting the fan where the blades will have at least 2.1 metres of clearance from the floor. 2.
INSTALLATION STEPS IMPORTANT: 1. 86” & 92” sizes require a minimum ceiling height of 2.7m. 2. Ensure the power is OFF when installing this fan. 3. WARNING: DO NOT place screws inside the motor holes without the blades being in place. Screwing into these holes without having the blades installed will cause damage to the fan and will void warranty.
Page 9
5. Take the downrod from the box and keep the side with 3 holes up. NOTE: 70” Sanctuary comes with two rods, 125mm and 250mm. Select one option (ensuring that the fan is not below 2.1m after install). 6. Feed the main motor wire plug and light wire plug (light model only) up through the inside of the downrod.
Page 10
FOR FLAT CEILING INSTALLTION Remove the Ball Joint from the Downrod Assemble the Hanger System as per the below. iii. Hang the fan into hanging and tighten it with 4 screws. Ensure it is secured and there is no wobbling. FOR RAKED CEILING INSTALLTION The Ball Joint comes pre-assembled on the downrod.
Page 11
iii. Align ball groove on hanging ball with ridge on hanging bracket. Ball Groove Ridge Ensure hanging ball is sitting into hanging bracket correctly. If fan doesn’t sit properly, hold the downrod and twist it util fan has been secured into hanging bracket IMPORTANT: DO NOT mix the hanging ball with the flat ceiling bracket (or vice versa).
Page 12
MODELS WITHOUT LIGHT Place bottom plate to the bottom of the motor and screw it clockwise into motor shaft until it is secured. IMPORTANT: Do not over turn. MODELS WITH LIGHT a. Remove the 3 screws on light kit fixing plate. b.
Page 13
CARE & CLEANING: • Periodic cleaning (approximately every 6 months) of your ceiling fan is the only maintenance required. • Use a soft brush or lint free cloth to avoid scratching the finish. Please turn off electricity when you do so. •...
CONSIDERATIONS: 1. If the receiver is not receiving a signal from the remote control: a. Please check the battery to ensure it has sufficient power, has been inserted correctly and aligns with the positive and negative terminals; and b. Please check if there are any other similarly remote-controlled objects that work nearby, as remote-controlled items operating on the same frequency may disturb each other.
TROUBLESHOOTING: Trouble Possible Cause Suggested Remedy Fans does not start Loose wire connections or Check wire connections and ensure plugs are plugs to fan/receiver positively connected No power goes into the fan Check RCD/Switch board and wiring on premises Fan with remote keeps Loose wire connections or Check wire connections and ensure plugs are beeping, but will not start...
Need help?
Do you have a question about the Sanctuary DC F6000 Series and is the answer not in the manual?
Questions and answers