WinSystems SYS-405Q-TCA7 Product Manual

Fanless industrial enclosed computer with intel atom x6425re quad-core processor in aluminum enclosure

Advertisement

Quick Links

SYS-405Q-TCA7
Fanless Industrial Enclosed Computer with
®
®
Intel
Atom
x6425RE Quad-Core Processor
in Aluminum Enclosure
Product Manual
WINSYSTEMS, Inc. | 2890 112th Street, Grand Prairie, Texas 75050 | 817-274-7553 | info@winsystems.com | www.winsystems.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SYS-405Q-TCA7 and is the answer not in the manual?

Questions and answers

Summary of Contents for WinSystems SYS-405Q-TCA7

  • Page 1 SYS-405Q-TCA7 Fanless Industrial Enclosed Computer with ® ® Intel Atom x6425RE Quad-Core Processor in Aluminum Enclosure Product Manual WINSYSTEMS, Inc. | 2890 112th Street, Grand Prairie, Texas 75050 | 817-274-7553 | info@winsystems.com | www.winsystems.com...
  • Page 2: Revision History

    WINSYSTEMS, Inc. The information in the document is subject to change without notice. The information furnished by WINSYSTEMS, Inc. in this publication is believed to be accurate and reliable. However, WINSYSTEMS, Inc. makes no warranty,...
  • Page 3: Table Of Contents

    SYS-405Q-TCA7 Table of Contents System Overview......... 5 1.1 External Connectors, Ports, and Inputs .
  • Page 4 SYS-405Q-TCA7 8.4.11 CFAST (SATA SSD) (J103)......... . 23 8.4.12 Basic Input/Output System (BIOS) Programming Defaults (JP9) .
  • Page 5: System Overview

    SYS-405Q-TCA7/System Overview System Overview The WinSystems SYS-405Q-TCA7 is a Single Board Computer (SBC) enclosed in a custom anodized aluminum enclosure. The SYS-405Q-TCA7 is a rugged, industrial system, capable of operating at extended temperatures without requiring a fan or heat-pipe. See “Introduction” on page 6.
  • Page 6: Before You Begin

    (SFF) Single Board Computer (SBC) capable of operating at high temperatures without a fan or heat-pipe. The processor for the unit is an Intel® Atom® x6425RE, integrated into the SYS-405Q-TCA7 using a Type 6 COM Express module. The low-profile thermal solution provides a rugged platform base that protects the PCB assembly and offers convenient four-point mounting.
  • Page 7: Product Features And Specifications

    SYS-405Q-TCA7/Product Features and Specifications NOTE WinSystems can provide custom configurations for Original Equipment Manufacturer (OEM) clients. For details, please contact an Application Engineer through Technical Support (see contact information in the page 6). Product Features and Specifications Features This section describes the features that are included with the SYS-405Q- TCA7.
  • Page 8 Temperature • Operating temperature: Fanless -40 °C to +85 °C (-40 °F to +185 °F); SYS-405Q-TCA7 requires a minimum airflow of 200 LFPM above 80 °C (176 °F) if input voltage (VCC) is above 24 V DC. • Storage temperature: -40C to +85C Construction •...
  • Page 9: Specifications

    Power up Plug in a compatible +10 to +50 VDC power source at J5. The first time power is applied, the SYS-405Q-TCA7 will boot automatically, bypassing the power button (SW1). After initial startup, briefly press the power button to turn the SYS-405Q-TCA7 on and off.
  • Page 10: Configuration

    SYS-405Q-TCA7/Configuration Configuration This section describes the SYS-405Q-TCA7 components and configuration. Component Layout 8.1.1 Edge Connections SERIAL- POWE DISPLAY AUDI SERIAL- Edge Connections: Connection Reference Power Input page 16 Power Button page 25 Audio: Line-In, Line-Out, and Mic In page 17...
  • Page 11: Watchdog Timer

    SYS-405Q-TCA7/Configuration Watchdog Timer The SYS-405Q-TCA7 features an advanced watchdog timer (WDT) that can be used to guard against software lockups. The timer is programmable from 1 second to 255 minutes. NOTE Use a long timeout if the watchdog is enabled when trying to boot any operating system.
  • Page 12 SYS-405Q-TCA7/Configuration Watchdog Timer Control Register for Minutes Offset Address: 0x07, Attribute: R/W, Size: 8 bit Description Timer Counter Register (Minutes) Watchdog timer time-out value in minutes (Default value = 0x00) Watchdog Timer Control Register for Seconds Offset Address: 0x08, Attribute: R/W, Size: 8 bit...
  • Page 13: Example Code (C Wdt)

    SYS-405Q-TCA7/Configuration 8.3.1 Example code (C WDT) The following code example for the watchdog timer is written in C: v1.0 www.winsystems.com Page 13...
  • Page 14: Example Code: Basic

    SYS-405Q-TCA7/Configuration 8.3.2 Example Code: Basic The following code example for the watchdog timer is written in Basic: v1.0 www.winsystems.com Page 14...
  • Page 15: Connectors

    SYS-405Q-TCA7/Configuration Connectors 8.4.1 System Management (J4) NOTE Systen Management is internal configuration option only. System management functions and events use J4 for connectivity from the SBC and CPU to the rest of the system. This enables the SBC and System to properly notify and respond to Power, Sleep/Wake, Thermal, and Security events.
  • Page 16: Power Input

    SPI_CLK SPI_MOSI SPI_CS5 8.4.2 Power Input The SYS-405Q-TCA7 is capable of operating from +10 to +50 VDC (+/-5%). The green powerinput connector (J5) is located next to the power button on the edge of the board. Warning Do not reverse the positive and negative terminals when you connect power to theunit.
  • Page 17: Audio: Line-In, Line-Out, And Mic In

    SYS-405Q-TCA7/Configuration 8.4.3 Audio: Line-In, Line-Out, and Mic In The SYS-405Q-TCA7 uses 3.5 mm stereo line-in, line-out, and microphone jacks at J6. 8.4.4 External Battery Connector (J7) (Optional) NOTE External Battery Connector is internal configuration option only. An external battery connected to the SYS-405Q-TCA7 board provides standby power for the real-time clock, CMOS, and optional GPS.
  • Page 18: Minipcie (J8)

    SYS-405Q-TCA7/Configuration 8.4.5 MiniPCIe (J8) NOTE MiniPCIe is internal configuration option only. The SYS-405Q-TCA7 includes a MiniPCIe socket at J8. Layout and Pin Reference: Name Name WAKE# 3.3Vaux 1.5V CLKREQ# REFCLK- REFCLK+ Mechanical Key W_DISABLE# PERST# PERn0 +3.3Vaux PERp0 +1.5V SMB_CLK...
  • Page 19: Minipcie With Sata Support (J9)

    NC = Not Connected 8.4.6 MiniPCIe with SATA Support (J9) NOTE MiniPCIe with SATA Support is internal configuration option only. The SYS-405Q-TCA7 includes a MiniPCIe socket at J9. The socket automatically detects mSATA, providing a bootable media and storage interface.
  • Page 20: Ethernet (Top Half Of Connectors)

    SYS-405Q-TCA7/Configuration +1.5V mSATA_DET +3.3Vaux NC = Not Connected 8.4.7 Ethernet (Top Half of Connectors) Two Intel I210 Gigabit Ethernet controllers provide standard IEEE 1588 and 802.1AS protocol timestamping. Each Ethernet interface includes 10/100/ 1000 MP/s multispeed, full, and half-duplex operation.
  • Page 21: Usb Channels 1 And 3 And Channels 2 And 4

    SYS-405Q-TCA7/Configuration 8.4.8 USB Channels 1 and 3 and Channels 2 and 4 CH1 port provides USB 2.0 on the top left and CH3 port provides USB 3.0 on bottom left. Both CH2 and CH4 ports provides USB 2.0. Pin Reference: (CH1) USB 3.0...
  • Page 22: Display Port 1.1

    SYS-405Q-TCA7/Configuration 8.4.9 Display Port 1.1 The Display Port 1.1 connector supplies both video and high definition (HD) audio. See the (XREF: Audio) section for more information. Layout and Pin Reference: Connector Name Description Name Description ML_Lane 0 Lane 0 (positive)
  • Page 23: Com 1 And Com 2

    8.4.11 CFAST (SATA SSD) (J103) NOTE CFAST is internal configuration option only. The SYS-405Q-TCA7 supports CFAST storage at J103 located on the back of the board. CFAST is a small form factor SATA SSD. Access the CFAST connector by removing the CFAST cover (see “Access the Enclosure” on page 1 for location).
  • Page 24: Basic Input/Output System (Bios) Programming Defaults (Jp9)

    SYS-405Q-TCA7/Configuration SGND Signal Ground Reserved Reserved 3.3 V Power Card Detect In 3.3 V Power Ground Ground No Connect Ground No Connect Card Detect Out 8.4.12 Basic Input/Output System (BIOS) Programming Defaults (JP9) NOTE This option requires removal of the enclosure cover.
  • Page 25: Switches

    8.5.1 Power Button The Power Button (SW1), located on the front I/O panel next to the power connector(J5). It controls power to the SYS-405Q-TCA7. The first time you connect power to J5, the power button is bypassed and the board powers up automatically.
  • Page 26: Appendix A. Best Practices

    TCA7. Measuring it at the power supply does not account for voltage drop through the wire and connectors. The SYS-405Q-TCA7 requires 10 - 50 VDC to operate. Verify the power connec- tions. Incorrect voltages can cause catastrophic damage. The SYS-405Q-TCA7 has a single power connector at J5.
  • Page 27 Power Supply OFF—Always turn off the power supply before connecting to the embedded system. Do not hot-plug the SYS-405Q-TCA7 on a host carrier board that is already powered. I/O Connections OFF—Turn off all I/O connections before connecting them to the embedded computer modules or any I/O cards.
  • Page 28 Conformal Coating Applying conformal coating to a WINSYSTEMS product does not in itself void the product warranty, if it is properly removed prior to return. Coating can change thermal characteristics and impedes our ability to test, diagnose, and repair products.
  • Page 29: Appendix B. Mechanical Drawings

    SYS-405Q-TCA7/Mechanical Drawings Appendix B. Mechanical Drawings Figure B–1: SYS-405Q-TCA7 Dimensions Measurement are in millimeters (Left) and in inches (Right). v1.0 www.winsystems.com Page 29...
  • Page 30: Appendix C. Warranty Information

    Products or licensing of Software hereunder. In the event this Order is placed in the hands of an attorney or collection agency by WINSYSTEMS to collect any sums due hereunder to WINSYSTEMS, Customer shall pay all reasonable attorney's fees, expenses, collection and court costs incurred by WINSYSTEMS.